0 INSTALLATION INSTALLATION Before Installing Installation Overview Please read the following installation instructions first after purchasing this product or transporting it to another location. The images in this guide may be different from the actual components and accessories, which are subject to change by the manufacturer without prior notice for product improvement purposes.
INSTALLATION 11 Tools Needed Parts Not Provided 50 AMP) b Strain relief (For conduit installations only) a Phillips screwdriver b Flat-blade screwdriver c 1/4" Nut driver d Pliers e Tape measure f Level g Adjustable wrench h Drill i Safety glasses j Gloves NOTE you the location of the circuit breaker or fuse. Mark it for easy reference. there are certain safety precautions you should follow. properly by a qualified installer or service technician.
12 INSTALLATION NOTE flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your range. n be installed on soft floor coverings such as cushioned vinyl or carpeting. Use care when moving the range on this type of flooring. Use a belt when moving the range to prevent damaging the floor. Or slide the range onto cardboard or plywood to avoid damaging the floor covering.
INSTALLATION 13 Dimensions and Clearances Dimensions ENGLISH - Dimensions LSEL6333*, LSEL6331* A Width 29 7/8" (759 mm) B Height 37 1/4" (946 mm) C Depth (Includes Door Handle) 29 7/32" (742 mm) D Height (Excludes Vent Trim) E Depth (Includes only the product body that is loaded into the cabinet. Excludes door, drawer, and handles) F Depth (Excludes Door Handle) 26 27/32" (682 mm) G Depth when drawer is fully opened 36 27/32" (935.
14 INSTALLATION Clearances a Acceptable electrical outlet area b Normal counter top depth c Counter top height d Cabinet e Wall f Center A (Cabinet opening) = 30" (76.2 cm) For U.S.A = 30" (76.2 cm) ~ 31" (78.
INSTALLATION 15 a 30" (76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an b 15" (38.1 cm) minimum between countertop and adjacent cabinet bottom. NOTE the local electrical inspector. -standing range is not to be installed closer than 15/32" (12 mm) from any adjacent surface. Leveling Connecting Electricity Leveling the Range Electrical Requirements Level the range by adjusting the leveling legs with a wrench.
16 INSTALLATION Specified Power Cord Kit Rating Case 1 Connecting the Power Cord / Conduit The rear access cover a must be removed. Loosen the two screws with a screwdriver. The terminal block will then be accessible. power supply-cord kit, amperes: 40 A or 50 A - Power cord: 1 3/8" - Conduit: 1 1/8" Case 2 power supply-cord kit, amperes: 50 A Use the cord/conduit connection plate b to install the power cord or conduit. Leave the connection plate as installed for power cord installations.
INSTALLATION 17 5 f Ring g Body CAUTION i Conduit nd strap connections. 3-Wire Connection: Power Cord WARNING white, of a 3-wire power cord or a 3-wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. Failure to do so can result in electrical shock, severe personal injury or death. in electrical spark and severe personal injury or death.
18 INSTALLATION 2 Insert the power cord through the strain relief and tighten it. CAUTION relief. cord without a strain 3 Remove the lower 3 screws from the terminal block and retain them. 4 Remove the ground screw and bend the end of the ground strap up so the slot is over the hole of the center screw removed in step 3. 5 6 Insert the ground screw into the power cord ground wire (green) terminal ring and secure it to the range frame.
INSTALLATION 19 2 4 Insert the two side bare wire ends into the lower left and the lower right terminal block openings. Tighten the 3 screws securely into the terminal block. (approximately 35 - 50 IN-LB) Conduit Installations CAUTION t without a strain relief. 1 Remove the cord/conduit connection plate from the rear of the oven and rotate it. 2 Prepare the conduit wires as shown below. a Cord/Conduit connection plate b Ground wire a Black b White 3 Install the conduit strain relief.
20 INSTALLATION 3 4 5 Attach the ground (green) bare wire end to the range frame and secure it in place with the ground screw. Insert the bare wire (white/neutral) end through the center terminal block opening. The center screw now attaches the bent up ground strap to the block. Optional Rear Filler Installing the Rear Filler If the counter does not bridge the opening at the rear wall, the rear filler kit which is provided with the slide in range will be needed.
INSTALLATION 21 following the guide on the anti-tip bracket template. Ensure the anti-tip device is reengaged when the range is moved by following the guide on the anti-tip bracket template. device if the range is moved. Do not operate the range without the anti-tip device in place and engaged. Engaging the Anti-tip Device ENGLISH to the structure and/or the range. Verify the anti-tip device has been properly installed and engaged by following the guide on the anti-tip bracket template.
22 INSTALLATION 4 Now check the oven's operation. Turn the oven mode knob to select the Bake mode. 350 °F appears in the display. Press START. 5 The oven should finish preheating in 15 minutes, and the convection fan should operate while the oven is preheating. 6 After checking the oven's operation, turn the temperature up to 450 °F and leave the oven on for at least an hour to help remove any oil which might cause smoke and odors when first using the oven. NOTE used.
OPERATION 23 OPERATION Control Panel Features Model: LSEL6333* Model: LSEL6331* a Features b Oven Control c +/- buttons d START e CLEAR/OFF f Smart DiagnosisTM g Cooktop control NOTE Flashing Clock - If the colon in the clock display flashes, press Clock and reset the time, or press any key to stop the flashing.