2 INSTALLATION INSTALLATION Before Installing Installation Overview Please read the following installation instructions first after purchasing this dryer or transporting it to another location. a Choose the proper location. b Level the appliance. c Vent the appliance. d Connect the inlet hose (for steam models) e Connect the Gas / Electric dryer. • Purchase a UL-listed, 3-wire or 4-wire power cord kit with UL-listed strain relief (electric dryer only) f Plug in the power cord.
INSTALLATION 13 Choosing the Proper Location Exhaust • The location must allow for proper exhaust installation. A gas dryer must be exhausted to the outdoors. Electricity Use an individual, grounded electrical outlet located within 2 ft. (61 cm) of either side of the appliance. WARNING • Do not install or store the appliance in an area where it will be exposed to water and/or weather.
14 INSTALLATION Dimensions and Clearances The following clearances are recommended for the appliance. • Additional clearances should be considered for ease of installation and servicing. • Additional clearances should be considered on all sides of the dryer to reduce noise transfer. Installation Spacing for Recessed Area or Closet Installation - Description Dimension/Clearance A Upper Ventilation Opening 2 48 sq. in. (310 cm2) B Lower Ventilation Opening 2 24 sq. in.
INSTALLATION 15 Closet Ventilation Requirements NOTE • There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one appliance to another. If there is enough vibration, it could cause appliances to make noise or come into contact, causing paint damage and further increasing noise. • No other fuel-burning appliance can be installed in the same closet as a dryer.
16 INSTALLATION Installation Spacing for Cabinet For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.
INSTALLATION 17 Leveling the Appliance and front to back. Make sure that all four leveling feet are in firm contact with the floor. WARNING ENGLISH • Use long-sleeved gloves and safety glasses. • The appliance is heavy. Two or more people are required when installing the appliance. NOTE Checking the Level Position the appliance in the final location and place a level across the top of the appliance.
18 INSTALLATION 2 You will be removing the screws shown below (6 on left, 4 on right). 3 Remove the four decorative screws on the left using a screwdriver. 7 Move the door to the left side and line up the holes in the hinge with the holes in the cabinet. WARNING • Be sure to support the weight of the door before inserting the hinge screws. 4 Remove the two latch screws and the latch. 8 Hold the hinge in place while inserting the two hinge screws (to prevent the door from dropping).
INSTALLATION 19 a 11 Check that the door closes and latches properly. 2 Press the tabs on the knockout c and carefully remove the knockout for the desired vent opening. (Right-side venting is not available on gas models.) Press the adapter duct d onto the blower housing and secure to the base of the dryer as shown. d Installing the Vent Kit WARNING • Use long-sleeved gloves and safety glasses. c 3 • Use a heavy metal vent. • Do not use plastic or thin foil ducts.
20 INSTALLATION • Do not stack the washer on top of the dryer. a b 2 Press the adapter duct c onto the blower housing and secure it to the base of the dryer as shown. c • If appliances are already installed, disconnect them from all power, water and drain connections. This stacking kit includes: • Two (2) side rails • One (1) front rail • Four (4) screws To ensure safe and secure installation, please observe the following instructions. 3 1 Make sure the surface of the washer is clean and dry.
INSTALLATION 21 4 • Ductwork is not provided with the dryer. You should obtain the necessary ductwork locally. The vent hood should have hinged dampers to prevent backdraft when the dryer is not in use. • The total length of flexible metal duct must not exceed 8 ft. (2.4 m). Ductwork Venting the Dryer Wall Cap Type Recommended 0 65 ft. (19.8 m) 1 55 ft. (16.8 m) 2 47 ft. (14.3 m) 3 36 ft. (11.0 m) 4 28 ft. (8.5 m) 0 55 ft. (16.8 m) 1 47 ft. (14.3 m) 2 41 ft. (12.5 m) 3 30 ft. (9.
22 INSTALLATION • The male end of each section of exhaust duct must point away from the dryer. • Use duct tape on all duct joints. • Insulate ductwork that runs through unheated areas in order to reduce condensation and lint buildup on duct surfaces. • Incorrect or inadequate exhaust systems are not covered by the dryer warranty. Dryer failures or service required because of such exhaust systems will not be covered by the dryer warranty.
INSTALLATION 23 • Use only a new AGA- or CSA-certified gas supply line (in compliance with the Standard for Connectors for Gas Appliances, ANSI Z21.24 • CSA 6.10) with flexible stainless steel connectors. Connecting the Gas Supply WARNING • DO NOT use old connectors. 4 Securely tighten all connections between the dryer and your laundry room’s gas supply. 5 Turn on your laundry room’s gas supply.
24 INSTALLATION death when using this appliance, fulfill the following requirements. Electrical Requirements for Electric Models WARNING • The wiring and grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all applicable local regulations. Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the appliance.
INSTALLATION 25 Attach the two hot leads (black and red) of the power cord to the outer terminal block screws. 6 Attach the neutral (white) wire to the center screw of the terminal block. 7 Attach the power cord ground wire to the green ground screw. 8 Tighten all screws securely. 9 Reinstall the terminal block access cover. b c 1’’ (2.5 cm) a 5’’ (12.7 cm) a Ground Wire 2 Remove the terminal block access cover on the upper back of the appliance.
26 INSTALLATION b c 4 Attach the two hot leads (black and red) of the power cord to the outer terminal block screws. 5 Attach the neutral (white) wire to the center terminal block screw. 6 Connect the external ground (if required by local codes) to the green ground screw. 7 Tighten all screws securely. 8 Reinstall the terminal block access cover.
INSTALLATION 27 1’’ (2.5 cm) b Neutral wire (white) c External ground wire (if required by local codes) Remove the terminal block access cover on the upper back of the appliance. 3 Install UL-listed strain relief into the power cord through-hole. 4 Thread the 3-wire, #10 AWG minimum copper conductor power cable prepared in step 1 through the strain relief.
28 INSTALLATION How to Connect the Water Inlet Hoses 1 2 washer hose to the washer and the other side of the Y-connector d. Check the fittings and seals. Inspect the threaded fitting on each hose and make sure there is a rubber seal a in place in both ends of each hose to prevent leaking. NOTE Check the type of installation and connect the hose to the faucet. Connect all water supply hoses tightly by hand and then tighten another 2/3 turn with pliers.
INSTALLATION 29 inch (1.5 cm). The dryer should be checked while the dryer is running with no load. NOTE • If any leaks are found, shut off the water faucet, remove the hose and check the condition of the rubber seal. Final Installation Check Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following tests. Test Dryer Heating Gas Models Close the dryer door and press the Power button to turn the dryer on.