,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 1 ENGLISH ESPAÑOL OWNER’S MANUAL AIR PURIFIER Read this owner's manual thoroughly before operating the appliance and keep it handy for reference at all times. Model name: AS401WWA1 www.lg.com MFL68181332 Rev.03_020817 Copyright © 2016 - 2017 LG Electronics Inc. All Rights Reserved.
1,MFL68181332,영영 17. 2. 9.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 3 PRODUCT FEATURES SMART AIR QUALITY SYSTEM The air quality display senses and shows indoor particulate levels in real time. It can sense fine particulate matter as small as 1.0 micron. MULTI-STAGE FILTRATION SYSTEM The combination of the washable pre-filter, PuriCare main filter, and deodorizing filter provide fresh indoor air by removing invisible air pollutants.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 4 4 SAFETY INSTRUCTIONS ENGLISH SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on the appliance. Always read and follow all safety messages. ! This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or injure you or others.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 5 SAFETY INSTRUCTIONS 5 • Do not install the product in direct sunlight, near heat sources such as furnaces or ovens, near fireplaces or other open flames, or in wet or humid locations. • Keep packing materials out of the reach of children. Packaging material can be dangerous for children. There is a risk of suffocation. • Store and install the product where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 6 6 SAFETY INSTRUCTIONS ENGLISH • Do not disassemble or repair the appliance by yourself. • Avoid any impact to the front panel of the appliance. California Safe Drinking Water and Toxic Enforcement Act WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 7 SAFETY INSTRUCTIONS • Do not insert inflammables inside the product. • Do not place the appliance where it can come into contact with the moisture from a humidifier. • Do not open the rear panel while the product is in operation. ENGLISH • Allow the pre-filter to dry completely, out of direct sunlight, after washing. Do not operate appliance with a damp filter. Do not operate appliance without pre-filter.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 8 8 PRODUCT OVERVIEW ENGLISH PRODUCT OVERVIEW Front Display Air Quality Indicator Light Light indicates the overall indoor air quality as detected by the dust and odor sensor. • Air Quality Levels (contaminated) Red → Orange → Yellow → Green (clean) Back Handle Dust sensor Odor sensor Filtration System (Pre-Filter@ Rear panel + Main Filter + Deodorizing Filter) Power cord Air inlet h The shape of power cord can be different by country.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 9 PRODUCT OVERVIEW 9 ENGLISH Control Panel and Display Overall air quality display Displays one of 4 colors to indicate the overall air quality. Odor Odor/Dust display Dust hr PM10 PM density display PM2.5 PM1.0 Fan speed display Sleep Timer display Auto Filter life light Fan Speed button Lock display Lock function Filter Reset button (3sec.) Reset(3sec.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 10 10 PRODUCT OVERVIEW ENGLISH Multi-Stage Filtration System Deodorizing Filter Case Main Filter Case Deodorizing Filter Pre-Filter Main Filter Filter name Pre-Filter Main Filter Deodorizing Filter Function Filters out large particles to prolong the lifespan of the Filter. Main Removes fine particles such as pollen, cigarette smoke (particulates), micro dust motes and animal fur.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 11 INSTALLATION Choosing the Proper Location • Place within reach of a power outlet. • Make sure air inlet and outlet are free from obstacles. • Place on a level, stable surface where air circulates freely. ! WARNING This product is not designed for maritime use or for mobile installations such as in RVs, trailers, or aircraft. Failure to follow this warning can result in product failure.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 12 12 INSTALLATION ENGLISH Initial Installation of Filter Remove the packaging before installing the filter. 1. Pull to open the rear panel. 2. Remove the filter from the appliance. 3. Remove the filter from its packaging. 4. Insert the filters with the deodorizing filter facing up. Make sure to slide the tabs on the top of the handle into the grooves at the top of the rear panel. Remove the vinyl. 5. Close the rear panel. 6.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 13 OPERATION 13 ENGLISH OPERATION Air Purification The air purifier cleans and refreshes indoor air. 1. Press the button to turn on the air purifier. • A chime sounds and the PM density display and the fan speed display turn on. 2. Press the Speed button to select the desired fan speed. (3sec.) Reset(3sec.) Speed Indicator Lighting Sleep Timer • Press the button repeatedly to toggle through the settings: Auto → Low → Medium → High → Turbo → Auto.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 14 14 OPERATION ENGLISH PM Indicator Display 1. Press the Indicator button to check the density of PM10/PM2.5/PM1.0. • Pressing the button repeatedly toggles through to check the density of PM10 → PM2.5 → PM1.0 in turn. The selected density displays for 10 seconds before the display reverts to the highest measured PM (particulate matter) level. (3sec.) Reset(3sec.) Lighting Speed Indicator Sleep Timer 2. Check the dust particle size LED indicators.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 15 OPERATION 15 ENGLISH Odor Dust PM10 Auto (3sec.) Reset(3sec.) Lighting Speed Indicator Sleep Timer • In the example above, the PM1.0 density displays at 50 ug/m³ (a bad or orange level) and the dust particle size LED indicator for PM1.0 is lit. This indicates that the PM1.0 level is higher than the PM10 or PM2.5 levels. If all the PM density levels are normal/good and the air quality indicator light is orange/red, the level of odors is very high.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 16 16 OPERATION ENGLISH Sleep Timer Use this to set the air purifier to sleep mode before it turns off automatically. 1. Press the button to turn on the air purifier. 2. Press the Sleep Timer set the amount of time in sleep mode until the air purifier automatically turns off. • The amount of time in sleep mode can be set by pressing Sleep Timer repeatedly to toggle through the options: 2 hours, 4 hours, 8 hours, 12 hours, disabled (reverts to normal display).
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 17 OPERATION 17 ENGLISH Lock Function 1. Press the button. 2. Press and hold the Speed Button and Indicator Button at the same time for 3 seconds or until a beep sounds and the lights up. • The Lock function helps protect the product from unwanted operation by children or others. • To disable the Lock function, press and hold the same time for 3 seconds. A beep sounds and the function is disabled.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 18 18 OPERATION ENGLISH Filter Reset The Filter Life light turns on based on the operating time. Filter Life light turns on after 4,000 hours. It is time to replace the filter. If Filter Life light turns on. 1. Press the button to turn off the product and then unplug the product. 2. Open the rear panel of the product and check the filter. If the filters are contaminated, clean or replace them.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 19 MAINTENANCE 19 Cleaning the Filters 1. Turn off the power and unplug the appliance. Then pull open the rear panel. (3sec.) Reset(3sec.) Speed Lighting Indicator Sleep Timer 2. Pull the filter set by the top handle to remove it from the appliance. • Dust may accumulate on the filter net. • Before disassembling filter set, move the filters to a convenient location for vacuuming. • Place a newspaper or paper towel down to catch any loose dust. 3.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 20 20 MAINTENANCE ENGLISH • Do not wash the Main Filter or the deodorizing filter with water. Replace them when they become very dirty. Do not expose them to water during operation. • The life-expectancy of filters may differ depending on the usage environment. 4. Press in the marked tabs on the sides of the deodorizing filter case to separate it from the PuriCare main filter case. 5. Remove and replace the deodorizing filter if necessary.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 21 MAINTENANCE 21 ENGLISH Filter Maintenance Schedule Filter types Pre-Filter Classification Cleaning cycle washable about every month Clean pre-filter with vacuum cleaner or brush, followed by rinsing under running water if very dirty. not washable, replace about every 12 months * The replacement cycle for Main Filter and Deodorizing Filter may vary depending on the usage environment.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 22 22 MAINTENANCE ENGLISH Cleaning the Sensor Turn off and unplug the product. Open the dust sensor cover. Clean the dust sensor lens with cotton swab. (Clean once every six months.) ! CAUTION • Use only water to clean the sensor. Failure to follow this warning can result in product failure.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 23 MAINTENANCE 23 If the product will not be used for an extended period, store it in a dry place out of direct sunlight. 1. Press the button to turn on the air purifier. • Run the air purifier for an hour on a clear day to remove any musty odor inside the product. (3sec.) Reset(3sec.) Speed Lighting 2. Press the unplug it. Indicator Sleep Timer button to turn off the air purifier and then Power plug 3.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 24 24 TROUBLESHOOTING ENGLISH TROUBLESHOOTING Before Calling for Service If there is a problem with the product, check the following first before calling for service. Problem Air purifier does not turn on. Possible Cause • Power cord not plugged in. • Incorrect power rating. Air output is weak, • Pre-filter is clogged. product makes a • Dust accumulation on the noise. Puricare Main Filter. • Indoor air quality is very bad. Air purification does not work well.
1,MFL68181332,영영 17. 2. 9. 영영 6:09 Page 25 TROUBLESHOOTING 25 Possible Cause Solutions There has been no • Sensor may be dirty or blocked • See instructions for cleaning sensor. by foreign material. change in micro dust • Air purifier may be in enclosed • Indoor air quality may stay the same in concentration. area. an enclosed area. The fine dust concentration value keeps showing high. Air quality light remains red/orange while PM levels show low/normal.
1,MFL68181332,영영 17. 2. 9. 영영 6:10 Page 26 26 SPECIFICATIONS ENGLISH SPECIFICATIONS Height Width Depth The external dimensions, design and product standards may change to improve the quality of the product. Model name AS401WWA1 Power supply 115 V~ / 60 Hz Suggested room size CADR*(ft³/min) Product size (width x height x depth) *CADR(Clean Air Delivery Rate) 217 ft² Smoke CADR : 140 Dust CADR : 175 Pollen CADR : 160 11 5/8 in. × 30 43/64 in. × 12 1/8 in.
1,MFL68181332,영영 17. 2. 9. 영영 6:10 Page 27 WARRANTY 27 Warranty Period Scope of Warranty One (1) year from date of original retail purchase Any internal / functional parts and labor Ten (10) years from date of original retail purchase Smart Inverter Motor Remark LG will provide parts and labor to repair or replace defective parts. Parts Only. Customer will be responsible for any labor or in-home service to replace defective parts.
1,MFL68181332,영영 17. 2. 9. 영영 6:10 Page 28 28 WARRANTY ENGLISH • Costs associated with removal of the product from your home for repairs. • The removal and reinstallation of the product if it is installed in an inaccessible location or is not installed in accordance with published installation instructions, including LG’s owner’s and installation manuals. • Damage resulting from misuse, abuse, improper installation, repair, or maintenance.