Sistema de Recaudo Control e Información y Servicio al Usuario Proyect Maintenance and Repair Manual (Heavy) Equipment Name CB-EDR-HM-00-V1.
Bogota SIRCI Project Document Maintenance and Repair Manual (Heavy) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition Document History Previous Version Present Document CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition Table Of Contents 1. ATTENDED RECHARGER STRUCTURE .................................. 1 1.1 Outline .............................................................. 1 1.2 External/Internal structure and main module ............................ 1 1.2.1 External structure ................................................... 1 1.2.2 Main module structure I .............................................. 3 1.2.3 Internal structure ...................................
Bogota SIRCI Project User Requirement Definition 1. Attended recharger structure 1.1 Outline Attended recharger is the device that recharges passenger’s card and managed by the crews. 1.2 External/Internal structure and main module 1.2.1 External structure 132mm (W) 185mm (H) 320mm (D) [Attended Recharger] CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 200mm (W) 35.6mm (D) 96mm (H) 342.6mm (H) [Customer Display] CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition Division Contents 320mm(D) x 185mm(H) x 132mm(W) Size Material PC+ABS 1.2.2 Main module structure I 132mm(W) 1) 185mm(H) 2) 3) 4) 320mm(D) Attended Recharger Name Explanation 1) Printer Print card recharging details 2) 4.3’ LCD Display attended recharger operation 3) RFID Antenna ISO14443 Type A/B, 13.56Mhz recognition and charging 4) KEYPAD Input the amount of recharge and information CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition Division Size Material Contents 35.6mm(D) x 96mm(H1) x 342.6mm(H2) x 200mm(W) PC+ABS 200mm(W) 35.6mm(D) 1) 2) 96mm(H1) 3) 342.6mm(H2) Customer Display Name Explanation 1) The amount before charging Display the amount before charging 2) The amount of charging Display the amount of charging 3) The amount after charging Display the amount after charging CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 1.2.3 Internal structure Printer Module Printer & LCD Board RFID Antenna Sub Main Board KEYPAD Board CPU Board CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 1.2.4 Main module structure II 1) 4.3’ LCD Display attended recharger operation 2) Printer Print various finishes, accounting journals and data etc. 3) RFID Antenna RF interface that be able to read 13.56MHz RF Card Available card : ISO 14443 Type A, B 4) CPU Board Control all part of the attended recharger and transfer processed information to the main server.
Bogota SIRCI Project User Requirement Definition 2. Error handling 2.1.1 Supply the power (1/2) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.2 Supply the power (2/2) Check DC Jack (J2) 12V Check U5 Output 5V Check U2 Output 8V Check U3 Output 5V Check U28 Output Check U1 Output 5V 3.3V Check U4 Output 3.3V CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.3 USB Trouble (1/2) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.4 USB Trouble (2/2) Check U21 USB HOST Controller Check USB Power Pin No.1 and 5V CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.5 LCD Screen Trouble (1/2) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.6 LCD Screen Trouble (2/2) Check LCD Data & Power Line (Sub Main B/D) Check LCD Data & Power Line (Print B/D) Check FFC Cable Check LCD Board CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.7 Keypad Trouble (1/2) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.8 Keypad Trouble (2/2) Check CPU Board Key Data Line & Power Line Check Key Board Key Data Line & Power Line Check KEYPAD Cable CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.9 RTC Trouble (1/2) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 2.1.1 RTC Trouble (2/2) Check RTC Battery Check RTC IC CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3. Device maintenance 3.1 CPU Board 3.1.1 Outline Control all part of the attended recharger and transfer processed information to the main server. 3.1.2 Structure Sub Main Board Printer & LCD Board RFID Antenna KEYPAD CPU Board TOP COVER CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3.1.3 Spec 1) CPU Spec ETHERNET RC531 EXT_UART USB 2.0 NAND FLASH S3C2440 NOR FLASH SDRAM CPU Board: The core board of attended recharger and drive main program so that manage all of communication and configuration modules. CPU - S3C2440(ARM9 Core) : 400MHz Memory - SDRAM : 128MByte - Nor : 8MByte - Nand : 512Myte RF module - RC531( Type A,B) EXT_UART - SB16C1054A (SYSTEMBASE) USB 2.0 - UBI9033 (UBISYS) ETHERNET CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition - W5100 (WIZNET) 2) SUB Board Spec Spare RS -232 Debug USB2.0 C/D Ethernet Power POWER Part RS-232 AC97 Codec SIM Slot Communicate with CPU Board and control various I/O device. External PORT - Ethernet : 1EA - USB2.0 : 1EA - External 3G Modem : 1EA - RS -232 : 3EA : C/D(Customer Display) 1, Debug 1, Spare Port 1 SAM - Socket 6EA(SIM Type) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition Sound - SW Codec control - Speaker : 1W * 2ea Input power - DC 12V/5A, use adopter 3) Printer & LCD Board Spec Communicate with Sub Main Board and control Printer & LCD. LCD - DC 3.3V input, GPIO communication Printer - DC 12V input, RS-232 communication CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 4) Antenna Board Spec Connected at CPU Board RC531, recognize the card. 5) Keypad Spec Transfer input key information to CPU Board. CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3.1.4 Replacement method 1) CPU board desorption 2 2 1 2 ① Separate FFC Cable that associated with Keypad and 3Pin Connector the associated with antenna board. ② Loosen the fixed bolts with Sub Board and separate Sub Board. 2) Sub Board desorption 1 2 2 1 2 1 2 1 1 2 ① Remove the cable the connected to Sub Board. ② Loosen fixed five bolts with Bottom Cover and separate Bottom Cover. CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3) Printer & LCD Board desorption 2 2 1 2 2 1 ① Remove cable that connected to Printer & LCD Board. ② Loosen fixed four bolts with TOP Cover and separate TOP Cover. 4) Antenna Board desorption 2 2 1 ① Remove cable that connected to Antenna Board. ② Loosen fixed two bolts TOP Cover and separate TOP Cover. CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 5) KEYPAD desorption 2 2 2 1 2 2 ① Remove cable that connected to KETPAD. ② Loosen fixed five bolts with TOP Cover and separate TOP Cover. CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3.1.5 Connector Spec A. POWER Cable CON 'A CON 'B '(SUB B/D J1) '(SWITCH) B. 1 WHITE 1 1 BLACK 1A PRINTER POWER Cable CON 'A CON 'B' '(SUB B/D J23) (PRINTER B/D CN1) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition C. PRINTER DATA Cable CON 'A' CON 'B' (SUB B/D J9) (PRINTER B/D CN3) 1 TX 2 2 RX 1 3 GND 3 4 DTR 4 5 DECO 5 D. Antenna Cable CON 'A' (CPU B/D J23) CB-EDR-HM-00-V1.
Bogota SIRCI Project E. User Requirement Definition Customer Display CON 'B' CON 'A' (CUSTOM DISPALY (SUB B/D J8) CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3.2 Customer Display 3.2.1 Outline Communicate with the attended recharger, display the amount before recharging, the amounting of recharging, the amount after recharging. 3.2.2 Structure Customer Display Stand CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3.2.3 Spec 1) Customer Display Spec FND FND control Power CPU Customer Display communicate with Attended Recharger, display the amount before recharging, the amount of recharging, the amount after recharging. CPU - ATMEGA64A Power - Attended Recharger supply DC 12V Communication - RS – 232 CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3.2.4 Replacement method 1) Customer Display
Bogota SIRCI Project User Requirement Definition 3.3 Maintenance Flow chart Receive replacement parts Error Check ERROR CODE Check maintenance referral and ERROR CODE Device maintenance and replacement due to MANUAL Device repair due to MANUAL Conduct TEST Conduct TEST OK NO OK NO Repair complete Repair complete 2) Required tool: Driver, tester, etc. 2) Precautions - Check each part of the adjustment value for every 12months or in a timely manner. CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 3) Detail check items No Items 1month 1 Power/ Voltage check 2 Printer operation check 3 Keypad operation check 4 LCD operation check 5 Customer operation check Inspection cycle 3months 6months 12months Note display 4. Attended recharger installation and update 4.1 Attended recharger installation 4.1.1 Process No 1 Division Device registration Contents 1) USB mounting method 2) SAM mounting 3) Power on … … … Note … 4.1.
Bogota SIRCI Project User Requirement Definition ② Insert USB TO USB PORT and turn on. ③ After update, reboot the theminal. 4.1.2.2 SAM Card mounting < Picture 1 > < Picture 2 > ① Picture 1: Loosen fixed bolts. ② Picture 2: Push in the direction of the arrow and separate completely. < Picture 3 > CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition ③ As shown in the Picture 3, push SAM slot in the direction of the arrow and lift SAM slot like as shown in the Picture 4l ④ After combine the SAM Card, push SAM slot in the direction of the arrow and secure ⑤ After SAM Card combined, assemble the back case. 4.1.2.3 Power ON ① Turn on power switch. ② Check T money logo on the screen after booting. CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition < Normal key input waveform> CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 4.1.3 Sub BOARD spec 4.1.3.1 Sub Main Board spec Communicate with CPU Board and control I/O device. Division CPU Memory RF Module Standard Note S3C24440 SDRAM : 128MByte Nor Flash : 8MByte Nand Flash : 512 MByte ISO 14443 Type A,B 4.1.3.2 Sub Main Board block diagram Customer Display board CB-EDR-HM-00-V1.
Bogota SIRCI Project User Requirement Definition 4.1.3.3 Sub Main I/O - RS-232 [3] DBG_TX [3] CUSTOM_TX [3] DBG_RX [3] CUSTOM_RX C37 100nF C-1005 1 C1+ TC3 3 C2+ 5 R86 R89 100R 100R R-1005 R-1005 11 10 DBG_RX R92 R94 100R 100R R-1005 R-1005 12 9 16 C38 2 C39 6 C40 14 7 R87 10uF/16V TC-3216-A 100nF C-1005 C1- 4 DBG_TX VCC 2 100nF C-1005 1 VDD_3.3V VDD_3.
Bogota SIRCI Project User Requirement Definition - SIM Part (Clock) SAM5.0V SAM5.0V 2 Y1 1 C47 100nF C-1608 4 VCC OUT 2 R124 1K R-1608 3 SIM_CLK1 GND 3.6864MHz(SCO-105) SAM5.0V SAM5.0V 2 Y3 1 C86 100nF C-1608 R1002 Z_0R R-1608 4 VCC OUT 2 3 R201 1K R-1608 R1003 0R R-1608 SIM_CLK2 GND 3.6864MHz(SCO-105) ① Circuit description : Circuit that supply the stable Clock to allow SIM Card to operate. CB-EDR-HM-00-V1.
Bogota SIRCI Project ② User Requirement Definition Waveform measurements - SIM Part (Signal) SAM5.
Bogota SIRCI Project User Requirement Definition FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. and (2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.