User's Manual

User Manual
Smart Thermal Scanner
Item No.: 40001
WELCOME TO LEXI
USER GUIDE - WORK WITHOUT LEXI HUB
1. Please select the ENVIRONMENT (NO HUB)
mode at the menu of LEXI App by selecting
"Add Environment/Hub"
2. Make sure your mobile's WiFi is turned on and
connected to 2.4G band and turned on the
location.
3. Power on your Thermal Scanner. Then, press
and hold the WiFi Button (A) for 3-5 seconds until
you see the WiFi logo at the display flashing.
4. Select "ADD NEW DEVICE" at the LEXI App and
follow the instruction to complete adding the
device(s). Once it the pairing was succeed, the
WiFi Logo will stop flashing.
5. Your devices is added to the LEXI system
successfully and ready to use.
6. To learn more about detail function and
special effect, Please go to www.lexilife.io
USER GUIDE - WORK WITH LEXI HUB
1. If you are using a LEXI Hub, make sure its
powered on and connected to the internet.
Also, make sure your LEXI Hub is ready to add
device(s) and work properly with the LEXI App at
your smart devices. ( Detail instruction at the User
Manual of LEXI Hub)
2. Make sure your mobile's WiFi is turned on and
connected to 2.4G band and turned on the
location.
3. Power on your Thermal Scanner. Then, press
and hold the WiFi Button (A) for 3-5 seconds until
you see the WiFi logo at the display flashing.
4. Select "ADD NEW DEVICE" at the LEXI App and
follow the instruction to complete adding the
device(s). Once it the pairing was succeed, the
WiFi Logo will stop flashing.
5. Your devices is added to the LEXI system
successfully and ready to use.
6. To learn more about detail function and
special effect, Please go to www.lexilife.io
INTROUCTION
LEXI Smart Thermal Scanner is suitable for use in
schools, offices, buses, supermarkets, subways
and other environments.
There are two installation methods; they’re wall-
mount or using bracket.
As It is a touchless Infra-red digital Thermal
Scanner, it reduces the risk of cross-infection.
The humanized design has an over-temperature
warning sound generated from the device and
LEXI App/mobile.
Simple to use and high accuracy.
FEATURES
1. Digital measurement of body temperature on
Forehead or Palm.
2. Instantly transmit the body temperature to
your mobile thro’ Wifi and show in LEXI App.
3. Celsius or Fahrenheit measurement
4. Fast operation to measure the temperature
within 2 sec
5. Accuracy with tolerance at ± 0.2 ºC
6. Display screen will turnoff automatically in
15sec when the sensor is idle to save power.
FUNCTION AND INDICATION DESCRIPTION
1) Indication Light -- 'Green' is Healthy, 'Red' is
Fever
2) Temperature value
3) Wifi connection indication
4) Temperature Sensor to sense palm or forehead
5) Motion detection sensor to sense the user
approaching
6) Temperature value in Celsius
7) Temperature value in Fahrenheit
8) High temperature alarm indicator
FUNCTION AND INDICATION DESCRIPTION
9) Wall Hanging hole at the back side of Thermal
Scanner.
10) 'WiFi' button (A)-- Press for 3 seconds, the icon
flashing for 60second. If WiFi connection success,
the icon will stop flashing. If not, the icon will not
show on the screen.
11) 'Select' button (B)- For measurement of
Celsius or Fahrenheit
12) 'Up' button(C) – Check for saved
temperature record
13) 'Down' button (D)-Check for saved
temperature record
Remark: Reset function -- Press Button A and B
the same time and hold for 5 seconds to reset
the device when the device has abnormal
conditions.
14) Power socket (USB-C)
15) Tripod nut
ACCESSORIES
a. DC5V1A Adaptor
b. USB Cable
c. Double adhesive pad (for wall sticking)
MEASUREMENT METHOD
1. Locate the forehead or palm close to the
middle sensor with a distance at 2-3inches apart
from the device for 2 second.
2. The measurement of body temperature will
display on the device and followed with a single
beep sound if the temperature is at healthy
condition.
3. If the user’s body temperature is higher than
99.14°F (37.3°C), the warning sound (fast
beeping) will be come out from the device and
at the same time your mobile will also has the
warning signal. The indication of display will
become RED at the mobile and device.
SELECTON OF CELSIUS/FAHRENHEIT
1. Short press the select Button B to switch the
Celsius/Fahrenheit
2. If you want to mute the sound of
measurement, press the Select Button B and hold
for 3sec for 3 seconds
WARNINGS AND CAUTIONS:
1.Don't use and storage at high temperature and
high humidity,
2. Do not drop it by gravity, or knocking on the
product will cause irreparable damage to the
product.
3. The product is for indoor use only. Do NOT
directly exposed to water, rain, sunlight, hot
surface and outdoors.
4. This product is not a toy designed to be
played with by children.
5. For safety reasons and under the terms of the
warranty, none of the enclosed devices should
be opened.
6. Only use the adapter supplied (with rating at
DC5V 1-2A), if using a different adapter can
damage the product.
CLEANING AND MAINTENANCE:
Pay attention to the daily maintenance of the
product, and clean the sensor dust in time to
obtain the best measurement accuracy.
Do not clean when the product is on and
connected to mains power. To avoid scratching,
the product should only be cleaned with a soft
dry cloth. Do not use cleaning agents.
WARRANTY:
LEXI provided one-year warranty is valid if the
product is used in accordance with the
instructions and for its intended purpose.
Claims will only be accepted on submission of
the original proof of purchase (invoice, sales
slip or receipt) stating the purchase date, the
name of the dealer and a description of the
product with product ID labeled at the
products. or Instruction manual.
The LEXI’s warranty lapses if:
a. Anything has been changed, crossed out,
deleted or rendered illegible on the purchase
docket or product description.
b. The failure is caused by damage, faulty
connections or abuse.
c. A defect is caused by extreme
circumstances not inherent to the product, for
example, lightning, flooding, fire, incorrect use
or negligence.
d. The product has been opened or
disassembled.
TROUBLESHOOTING
a. Ensure your device is within 60ft without an
obstacle between either your LEXI Hub or your
mobile phone (when being used without a Hub)
b. Ensure your mobile phone has turned on both
WiFi (2.4G band) and location services.
c. Make sure the green light is not flashing. The
flashing green light means the connection with
WiFi is not success. Please re-connect the device
with WiFi.
d. Confirm device is paired with LEXI Hub or with
your mobile phone
e. You can un-pair the device by LEXI App when
necessary.
TECHNICAL INFO:
Input voltage: DC5V 1-2A
Measuring distance: 2-3 inches (apart from the
sensor)
Measurement Range: 89.6-109.2°F (32-42.9°C)
Measuring time : 2sec
WIRELESS SPECIFICATION:
Frequency: 2412-2472MHz
Wireless communication protocol:
802.11b/802.11g/802.11n
ENVIRONMENTAL SPECIFICATION:
Temperature (operation): 50-95°F
Temperature (storage): -13...140°F Relative
humidity: 10-80% non-condensing
PLEASE KEEP THIS PACKAGING FOR FUTURE
REFERENCE AS IT CONTAINS IMPORTANT
INFORMATION.
DISPOSAL OF YOUR OLD PRODUCT:
Your product is designed and manufactured
with high quality materials and components,
which can be recycled and reused. When
this crossed-out wheeled bin symbol is attached
to a product it means the product is covered by
the European Directive 2002/96/EC.
Please find out for yourself about the local
separate collection system for electrical and
electronic products. Please act according to
your local rules and do not dispose of your old
products with your normal household waste. The
correct disposal of your old product will help
prevent potential negative consequences for
the environment and human health.
FCC WARNING AND CAUTION:
- This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful
interference, and
(2) this device must accept any interference
received, including interference that may cause
undesired operation.
- Changes or modifications to this unit not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
FCC ID : 2ATOT40001
- Shielded Cables must be used with this unit to
ensure compliance with the Class B FCC limits
NOTE: This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference in a residential installation.
NOTE:
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used in accordance with the instructions, may
cause harmful interference to radio
communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning
the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the
equipment and receiver.
- Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV
technician for help.

Summary of content (1 pages)