User's Manual

Plug-In Serial Interface Module
Cat. No. VRC0P-1LW
Rated: 120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-VRC0P-02A-X1
INTRODUCTION
Leviton’s Vizia RF +
TM
components are designed
to communicate with each other via Radio
Frequency (RF) to provide remote control
of your lighting. Using RF technology allows
Leviton to provide the greatest signal integrity
possible. Each module in Leviton’s Vizia RF +
TM
component line is a Z-Wave
®
enabled device. In
a Z-Wave
®
network, each device is designed to
act as a router. These routers will re-transmit the
RF signal from one device to another until the
intended device is reached. This ensures that
the signal is received by its intended device by
routing the signal around obstacles and radio
dead spots.
CAUTION:
Remember to exercise good common sense
when using the Timer features of your remote,
especially when scheduling unattended devices.
There can be some unexpected consequences if
not used with care. For example, an empty coffee
pot can be remotely turned on. If that should
happen, your coffee pot could be damaged from
overheating. If an electric heater is turned on by
remote control while clothing is draped over it, a
re could result.
Including Plug-In Serial
Interface Module into Z-Wave
TM
Network:
Step 3
Attaching Plug-In Serial
Interface Module to Wall
Receptacle:
Step 2
Attaching Serial-RS232 Cable
or HAI Cable to Plug-In Serial
Interface Module:
Step 1
NOTE: In order to use your Vizia RF +
TM
Plug-In
Serial Interface Module in a Z-Wave
®
network, it
must be Included into the network using a Primary
Programmer/Remote, such as Leviton’s Cat. No.,
VRCPG. Before Including your module, please refer
to the Primary Programmer/Remote instruction
sheet for complete information. Refer to Step 3 for
further details.
NOTE: Use check boxes when Steps
are completed.
INSTALLING YOUR INTERFACE MODULE
RS232 cable
to CPU
HAI cable
to HAI controller
RS232 cable to
Interface Module
HAI cable to
Interface Module
OR
WARNINGS AND CAUTIONS:
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
WARNINGS AND CAUTIONS:
Save this instruction sheet. It contains important technical data along with testing
and troubleshooting information which will be useful after installation is complete.
RS232 - ASCII
Scene capable
Two way communication
RF reliability
Ease of installation – No new wiring
Compatible with other Z-Wave
®
enabled
devices
NOTE: This product requires the use of third
party software to function, along with a relatively
high level of programming skill.
FEATURES
Step 3 cont’d
Programming
Button
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Programmer/Remote
Cat. No. VRCPG
Center Button
Menu Button
NOTES:
If using a non-Leviton Programmer/Remote,
refer to the Programmer/Remote instruction
sheet.
Plug-In Serial Interface Modules included into
a Z-Wave
®
network must be updated after you
have included all other devices.
If using VRCPG Installation Checklist feature, go
to Step B.
A)
If using a Leviton Z-Wave
®
Programmer/
Remote, Cat. No. VRCPG, press the Menu
button and scroll down to System. Press the
center button to select System Menu. Choose
Advanced. Press the center button to select
Advanced Install
. Press the center button to
<Include Node>.
B) If using VRCPG Programmer/Remote, you will
be prompted to prepare device for inclusion. To
do this you must put the Plug-In Serial Interface
Module into programming mode.
C) To access Program mode, press and hold
programming button until the LED turns Amber.
Release the button and the LED will blink Amber.
You are now in Programming mode.
NOTE: If the LED on the Plug-In Serial Interface
Module turns solid Red while excluding, there
has been a communication error.
D) While standing close to the Plug-In Serial
Interface Module (approximately 1 ft.), press
the center button on the Programmer/Remote
to <Include> device in the network. NOTE: Only
one device may be included at any time.
E) The Primary Programmer/Remote will assign
a Home ID, Node ID, and Name for this
device.
NOTE: This information will be stored in the
Programmer/Remote to be used for future
reference.
NOTE: You may name or edit your device at
this time.
F) The Plug-In Serial Interface Module is now
installed in the network.
G) After all devices are included into the network,
the Plug-In Serial Interface Module must be
updated to allow proper network function.
To update Plug-In Serial Interface Module
proceed as follows:
If using a non-Leviton Programmer/
Remote, refer to the Programmer/Remote
instruction sheet for updating Plug-In
Serial Interface Module.
If using a Leviton Z-Wave
®
Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll
down to System. Press the center
button to select System Menu. Choose
Advanced. Press the center button to
select Advanced Install. Scroll down
and select Update Controller. When
prompted, press button on the Plug-In
Serial Interface Module.
Wait until the VRCPG Programmer/
Remote conrms completion. Update
is done.
NOTE: If the Plug-In Serial Interface Module
has been successfully Included in the network
and the user tries to Include it again without rst
excluding it from the network, the controller will
retain the rst node ID it had received and ignore
the second.
Attach RS232 cable to Plug-In
Serial Interface Module and
CPU.
OR
Attach HAI cable to Plug-In
Serial Interface Module and
HAI controller.
Plug the Plug-in
Serial Interface
Module into wall
receptacle. Verify
that receptacle is
live. If controlled by
a wall switch, the
switch must be kept
ON at all times.