User's Manual

NOTES:
• Ifusinganon-LevitonProgrammer/Remote,
refertotheProgrammer/Remoteinstruction
sheetforIncludingadevice.
• IfusingtheVRCPG'sInstallChecklistfeature,
godirectlytoStepB.
A)IfusingaLevitonZ-Wave
®
Programmer/
Remote,Cat.No.VRCPG,presstheMenu
buttonandscrolldowntoSystem.Pressthe
centerbuttontoselectSystemMenu.Choose
Advanced.Pressthecenterbuttontoselect
AdvancedInstall.
Scene Capable Plug-In Lamp Dimming Module
Cat. No. VRP03-1LW
Rated:120VAC,60Hz
Incandescent:300Wmax.,14Wmin.
INSTALLATION INSTRUCTIONS
DI-030-VRP03-02A-X1
INTRODUCTION
Leviton’sViziaRF+
TM
componentsare
designedtocommunicatewitheachother
viaRadioFrequency(RF)toprovideremote
controlofyourlighting.UsingRFtechnology
allowsLevitontoprovidethegreatestsignal
integritypossible.EachmoduleinLeviton’s
ViziaRF+
TM
componentlineisaZ-Wave
®
enableddevice.InaZ-Wave
®
network,each
deviceisdesignedtoactasarouter.These
routerswillre-transmittheRFsignalfromone
devicetoanotheruntiltheintendeddevice
isreached.Thisensuresthatthesignalis
receivedbyitsintendeddevicebyroutingthe
signalaroundobstaclesandradiodeadspots.
CAUTION:
Remembertoexercisegoodcommonsense
whenusingtheTimerfeaturesofyourremote,
especiallywhenschedulingunattended
devices.Therecanbesomeunexpected
consequencesifnotusedwithcare.For
example,anemptycoffeepotcanberemotely
turnedon.Ifthatshouldhappen,yourcoffee
potcouldbedamagedfromoverheating.Ifan
electricheateristurnedonbyremotecontrol
whileclothingisdrapedoverit,arecould
result.DO NOT USEtheremoteforthecontrol
ofhighpowerheatingappliancessuchas
portableheaters.Thisdevicewillnotcontrol
lightingthatisusedwithelectroniclow-voltage
andhighfrequencypowersupplytransformers,
norhighpressuredischargelamps(HID
lighting).Thisincludesmercury-vapor,sodium
vaporandmetalhalidelamps.DO NOT
changelocationafterunitisenrolledinZ-wave
®
network.
Including Scene Capable
Plug-In Lamp Dimming Module
into Z-Wave
®
Network:
Step 3
Attaching Scene Capable
Plug-In Lamp Dimming
Module to Wall Receptacle:
Step 2
• PlugthePlug-inDimmerModuleintowall
receptacle.Verifythatreceptacleislive.If
controlledbyawallswitch,theswitch
must be kept ONatalltimes.
Attaching Load to Scene
Capable Plug-In Lamp
Dimming Module:
Step 1
NOTE:InordertouseyourViziaRF+
TM
Scene
CapableLampDimmingModuleinaZ-Wave
®
network,itmustbeIncludedintothenetwork
usingaPrimaryProgrammer/Remote,suchas
Leviton’sCat.No.,VRCPG.BeforeIncludingyour
module,pleaserefertothePrimaryProgrammer/
Remoteinstructionsheetforcomplete
information.Refer to Step 3 for further details.
• LocatelamptobecontrolledbyScene
CapablePlug-InLampDimmingModuleand
ensureitisfullyoperational.Attachlampplug
intomodulereceptaclenotingproperpolarityof
blades.
NOTE:UsecheckboxeswhenStepsare
completed.
INSTALLING YOUR DIMMING MODULE
B)Whilestandingclosetothemodule
(approximately1foot),pressthecenter
buttonto<Include>deviceinthenetwork.
NOTE:Onlyonedevicemaybeincluded
atatime.DO NOTputmultipledevicesinto
theInclusionmodeatanytime.
C)WhiletheProgrammer/Remoteisinthe
InclusionmodeandtheLEDisONonthe
SceneCapablePlug-InLampDimming
Module,presstheON/OFFbuttononthe
module.TheProgrammer/Remotewillverify
inclusionandtheLEDwillturnOFFonthe
SceneCapablePlug-InLampDimming
Module.
NOTE:IftheLEDontheSceneCapable
Plug-InLampDimmingModuleturns
solidRedwhileincluding,therehas
beenacommunicationerror.Refer to
Troubleshooting section.
D)ThePrimaryProgrammer/Remotewill
assignanodeIDnumber(Name)forthis
module.
NOTE:ThisIDnumber(Name)willbe
storedinthecontrollertobeusedforfuture
reference.
NOTE:Youmaynameoreditthisdeviceat
thistime.
E)The module is now installed in the
network.
NOTE:Ifthemodulehasbeensuccessfully
Includedinthenetworkandtheusertriesto
Includeitagainwithoutrstexcludingitfrom
thenetwork,themodulewillretaintherst
nodeIDithadreceivedandignorethesecond.
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.
• Toreducetheriskofoverheatingandpossibledamagetootherequipmentdonotinstalltocontrola
motor-operatedappliance,uorescentlightingxture,oratransformersuppliedappliance.
WARNINGS AND CAUTIONS:
• Unplugunitwhenservicingconnectedlightingxtures.
• Savethisinstructionsheet.Itcontainsimportanttechnicaldataalongwithtesting
andtroubleshootinginformationwhichwillbeusefulafterinstallationiscomplete.
• SoftfadeON/OFF
• Scenecapable
• ON/OFFLED
• Twowaycommunication
• ManualONcapabilityatload
• RFreliability
• Easeofinstallation–Nonewwiring
• CompatiblewithotherZ-Wave
®
enableddevices
FEATURES
Step 2 cont’d Step 3 cont’d
Programming and
ON/OFF Button
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Programmer/Remote
Cat. No. VRCPG
Center Button
Menu Button

Summary of content (2 pages)