WARNINGS AND CAUTIONS:
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult a qualified electrician.
To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer
operated appliance.
Use with magnetic low-voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low-voltage dimmer to control electronic
(solid state) low-voltage transformers.
When magnetic low-voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible
transformer failure due to overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings.
Vizia
TM
RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia
TM
RF controllers for multi-location dimming.
WARNINGS AND CAUTIONS:
Use only one (1) Vizia
TM
RF dimmer in a multi-location circuit with up to 9 coordinating Vizia
TM
remotes without LEDs or Vizia
TM
RF remotes for multi-location. The remote(s)
will turn the light on at the brightness level selected at the dimmer.
Total minimum load must exceed 40W.
Dimmer may feel warm to the touch during normal operation.
Recommended minimum wall box depth is 2-1/2".
Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Single Pole (One location) or 3-Way (Multi-location)
Scene Capable Magnetic Low-Voltage Dimmer
Cat. No. RZM10-1L, 1000VA (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
IMPORTANT : For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a different
color (Black) or labeled Common. Tag that wire with electrical tape and
identify as the common (Line or Load) in both the dimmer wall box and
remote wall box.
For non-standard wiring applications, refer
to Wire Nut and Connector Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
DI-000-RZM10-00A-X2
Pull off pre-cut insulation from dimmer leads.
Make sure that the ends of the wires from the wall box are
straight
(cut if necessary).
Remove insulation from each wire in the wall box as shown.
For Single-Pole Application, go to Step 4a.
For 3-Way Coordinating Remote (no LEDs) Application, go to
Step 4b.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING:
CONNECT A MAGNETIC LOW-VOLTAGE DIMMER
ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC
LOW-VOLTAGE TRANSFORMER.
Green or bare copper wire in wall box to Green dimmer lead.
Line Hot wall box wire to Black dimmer lead.
Load wall box wire to Red dimmer lead.
Line Neutral wall box wire to White dimmer lead.
Yellow/Red dimmer lead should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer lead,
use electrical tape to cover.
Proceed to Step 5.
3-Way Wiring with Coordinating Dimming or
Switching Remote (no LEDs) Application:
Step 4b
BL
YL/RD
RD
Coordinating Remote
Dimmer
5
2
1
4
3
1
4
3
Black
White
Green
Red
Yellow/Red
2
5
Hot (Black)
Neutral (White)
Coordinating Remote (no LEDs)
YL/RD
RD
Load
Black
BK
WH
White
Line
120VA
C, 60Hz
Green
Ground
Dimmer
BlackRed
Yellow/
Red
(PRIMARY SIDE OF
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
White
Green
Ground
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING:
FOR MAGNETIC LOW-VOLTAGE APPLICATIONS,
CONNECT DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE)
SIDE OF A MAGNETIC LOW-VOLTAGE TRANSFORMER.
NOTE: When using the coordinating remote without LEDs, the
dimmer can be installed on either the Line or Load side of the 3-way
circuit.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
Green or bare copper wire in wall box to Green dimmer lead.
Line Hot (common) wall box wire identified (tagged) when
removing old switch to Black dimmer lead.
First Traveler wall box wire to Red dimmer lead
(note wire color).
This traveler from the dimmer must go to the terminal screw on
the remote marked “RD”.
Remove Red insulating label from Yellow/Red dimmer lead.
Second Traveler wall box wire to Yellow/Red dimmer lead
(note
wire color). This traveler from the dimmer must go to the terminal
screw on the remote marked “YL/RD”.
Line Ne
utral wall box wire to White dimmer lead.
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Cutters Ruler
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the reduction of the dimmer’s capacity
is required. Refer to the chart for maximum load per dimmer.
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER
section. If installing Dimmer in a multi-
device application, proceed as follows:
Installing Dimmer by itself or with other devices:
Changing the color of your Dimmer:
Your Dimmer includes three color options. The Dimmer ships with the
White frame attached. To ch
ange color of frame, proceed as follows:
Line up tabs and
press in side to attach
Push in side at
tab to release
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.












WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
Step 1
Step 2
2
4
3
1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any
of these configurations, consult a qualified electrician.
3-Way
1. Line or Load
(see important instruction)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
2
4
1
5
3
Cut
(if necessary)
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary). Remove insulation from each wire in the wall
box as shown:
Step 3
Dimmer
Insulating
Label
Black
Hot (Black)Black
Line
120 VAC, 60Hz
Neutral (White)
Red
Yellow/
Red
White
(PRIMARY SIDE OF
MAGNETIC LOW-VOLTAGE
TRANSFORMER)
White
Green
Ground
Single Pole Wiring Application:
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.
1
4
3
Black
White
Green
Red
Yellow/Red
2
Step 4a
MAXIMUM BULB WATTAGE
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the efficiency of the transformer in the low-
voltage lighting system. Transformer efficiencies will vary from different
manufacturers; consider 80% efficient as average. Use the chart to
determine maximum bulb wattage for typical transformer efficiency ratings.
Remove all
inner side
sections
Do not
remove
outer side
sections
Bend back
and forth to
remove side
section
Compatible with enabled products!
TM
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than
2 Devices
650W
650VA
Two Devices
800W
800VA
Single
1000W
1000VA
Load
Incand
Mag LV
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
More than
2 Gang
520W
Two
Gang
640W
Single
800W
Rating
1000VA
Step 2 cont'd