User Manual

Operating Instructions 1 31083A
RF DATA COLLECTOR
MODEL 22240
FCC ID #OBH22240
PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS
For correct operation of the equipment, it is important to read and be familiar
with this entire manual before installing and operating the charger.
DO NOT DISCARD THIS MANUAL AFTER READING.
LOOK FOR THIS SYMBOL TO POINT OUT SAFETY PRECAUTIONS. IT MEANS:
BECOME ALERTYOUR SAFETY IS INVOLVED. IF YOU DO NOT FOLLOW THESE
SAFETY INSTRUCTIONS, INJURY OR PROPERTY DAMAGE CAN OCCUR.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
INSTALLATION INSTRUCTIONS
Tools needed to install RF Data Collector Model
22240: 11/32" nut driver, Phillips screwdriver,
Anderson Connector-Terminal Cable extractor
CAUTION: USE CAUTION WHEN WORKING
WITH INDUSTRIAL BATTERIES; THEY CAN BE
VERY DANGEROUS. INDUSTRIAL BATTERIES
CONTAIN ACID (ELECTROLYTE SOLUTION)
WHICH CAN CAUSE CHEMICAL BURNS AND
SERIOUS HARM TO SKIN AND EYES. ALWAYS
WEAR APPROVED PROTECTIVE EYE GOGGLES
AND RUBBER GLOVES. AVOID PROLONGED
BREATHING OF BATTERY VAPORS; WORK IN A
WELL-VENTILATED AREA. BATTERY VAPORS
CAN BE FLAMMABLE. DO NOT REST TOOLS
ON TOP OF BATTERY OR ALLOW ANY METAL
OBJECTS TO COME IN CONTACT WITH
BATTERY POSTS OR INTER-CELL
CONNECTORS.
ASSEMBLY PROCEDURE
1. Examine the cables between the battery and DC
plug. With caution, use the Anderson Terminal-
Cable extractor to remove only the positive
(RED) battery cable contact from the battery DC
plug housing.
2. From the RF Data Collector case assembly,
remove the bottom half of the case and the
plastic cord clamping device.
3. Carefully slide the positive (RED) cable contact
through the BLUE ring toroid, located in the top
half of case, with the ring "end" of the Data
Collector facing the battery. Reposition the RED
cable contact inside the battery DC plug
housing. Locate the RF Data Collector case top
(with LED facing up) close to the DC plug
housing and outside of all metal enclosures.
4. Lay the negative (BLACK) battery cable in the
area provided next to the positive (RED) cable.
5. Position the plastic battery cable clamp over
both of the wires so that the clamp slides easily
over the studs located in the RF Data Collector.
Verify that the arrows on top of the clamp point
toward the BLUE ring/battery end of the cables.
6. Using hand pressure only, carefully exert
downward force on the plastic battery cable
clamp until enough of the studs protrude through
the clamp to allow starting the hex nuts.
Exhibit 8
FCC ID#: OBH 22240

Summary of content (2 pages)