Datasheet

OFFICE
MegaLine
®
F6-90 S/F flex
S
2
P
3
A
4
C
1
E
5
Type:
KS-02YSCH 4x2xAWG 27/7 PIMF
Category: 7
Construction:
1 Conductor:
2 Insulation:
Twisting element:
3 Individual screen:
Twisting:
4 Overall screen:
5 Outer sheath:
bare copper wire, AWG27/7
cellular-PE, core-Ø: max. 1.0 mm
pair
aluminium-bonded polyester tape
4 pairs
tinned copper wire braid
halogen free, flame retardant compound
colour code:
Colour outer sheath:
wh/bl, wh/or, wh/gn, wh/br
grey, RAL-7035
printing outer sheath:
LEONI MegaLine F6-90 S/F flex 4P H SPACE Code 23415 Dca s2 d2 a1 Number of registration VDE 8080 $Production lot code$
$Meter marking$
fire behaviour:
flame resistance:
halogen free:
smoke resistance:
Acidity:
fire load (MJ/m):
Class:
acc. to IEC 60332-1-2
acc. to IEC 60754-1/2
acc. to IEC 61034-1/2
according EN 60754-2
0.33 (approx.)
Dca s2 d2 a1
according EN 50575 / EN 50399
performance:
better than Category 7 acc. to EN 50288 and IEC 61156 excellent
NEXT, exzellente screen properties (pair- and overall screen), low
Skew
bandwidth (typical): 900 MHz
applications:
Connecting cable and patch cord for generic cabling systems acc. to ISO/IEC
11801 and EN 50173 (2nd edition). Ideal for all applications of class D up to F
Multimedia (Video, Data, Voice) >10 GbE acc. to IEEE 802.3 an, Cable sharing,
VoIP, PoE/PoE+
mechanical characteristics:
bending radius:
in operation: 5 x outer diameter (min.)
tensile loading (N): 40 (max.)
electromagnetic behaviour:
transfer impedance at 10 MHz (mOhm/m):
screen attenuation up to 1000 MHz (dB):
coupling attenuation up to 1000 MHz (dB):
Segragation class according EN 50174-2::
5 (nominal value)
60 (nominal value)
80 (nominal value)
d
S
1
IEC 60332-2-2
2
IEC-60332-1-2
E
ca
/D
ca
3
IEC-60332-3-24
E
ca
/D
ca
4
EFP Grade 1
C
ca
5
EFP grade 2
B
2ca
Security (fire behaviour)
P
1 > class E >
250 MHz
2 > class EA >
500 MHz
3 > class F >
600 MHz
4 > class FA >
1000 MHz
5 > class G >
1200 MHz
Performance (class, bandwidth)
A
1 > 100 MbE 2 > 1 GbE 3 up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV
application (Ethernet, TV)
C
1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22
Construction (conductor size, tensile strengh)
E
1 > 40 dB 2 > 50 dB 3 > 60 dB 4 > 70 dB 5 > 80 dB
EMC (coupling attentuation)
LEONI Kerpen GmbH Zweifaller Str. 275-287 D-52224 Stolberg, Tel. +49(0)2402-17-1, Fax +49(0)2402-75154, E-Mail datacom@leoni.com, www.leoni-data.com
printing error, falsity and technical alterations excepted.
The origin document is german. In case of error has the german translation priority.

Summary of content (2 pages)