a.In standby mode, using a pen to press LEARN button once will
sound beep, press again will sound other one, press the button
select sound for you want, then keep press LEARN button 2
seconds will hear a beep tone then release the button, the unit now
ready to receive learn code signal from transmitter.
b.Trigger wireless garage door open detector sensor (pull up and put
down detection rob will trigger it ), you will hear a long beep tone
confirming that the progamming of learn code was done
successfully (When programming LEARN code was unsuccessful,
you will hear four short beep tones). Please program again.
Learn ID code to T016S,T015S auto dialer main unit:
a. Open terminal compartment of main unit. ( Fig.4)
b. Press and hold LEARN button 2 seconds you will hear one beep
tone then un-pressed the button, the unit now ready to receive
learn code signal from transmitter.
c. Trigger wireless garage door open detector sensor (pull up and put
down detection rob will trigger it ).
d. You will hear a long beep tone confirming that the programming of
learn code was done successfully (When programming LEARN
code was unsuccessful, you will hear four short beep tones).
Please program again.
Learn ID code to T018S auto dialer main unit:(Fig.5)
a. Enter the pass number followed by
PROGbutton three times.
b. The " LEARN " icon will flash on the LCD.
c. Press
ARM/DISARMto confirm, the system will turn into
learning ID code setup and zone 1 icon flash.
d. Press the
*/UPand#/DOWNbuttons to select you want
setup zone, when LCD display “NO ID CODE” is meaning the zone
is disengaged, you can learn new sensor id code for this zone;
when LCD display “FULL” is meaning the zone had ID code,you
can select other zone or press
DEL./PAUSEbutton to delete
( Fig. 4 )
( Fig.5)
2
original id code then relearn new id code for this zone.
e. PressARM/DISARMto confirm.
f. Trigger wireless garage door open detector sensor (pull up and
put down detection rob will trigger it ).(Fig.5)
g. you will hear a long beep tone confirm learn code successfully and
LCD will display “FULL” for zone 1 ~ zone 8 or “1 ID CODE IN”
for zone 9.
h. pressPROGbutton seven times to exit the setup mode.
Learn ID code to 526L wireless outdoor siren with flash light:
a. Open battery compartment cover. ( Fig.6)
b. use a pen to press and hold LEARN button for 2 seconds, a beep
tone will sound , then release the button, the unit now ready to
receive LEARN ID code signal from transmitter.
c. Trigger wireless garage door open detector sensor (pull up and
put down detection rob will trigger it )
d. you will hear a long beep tone confirming that the programming
of learn code was done successfully (When programming LEARN
code was unsuccessful, you will hear four short beep tones).
Please program again.
4. TO TEST TRANSMITION RANGE
After select a location, you should test the sensor transmitting
range before mount it permanently, turn power switch to ON of
625RX main unit or turn the CHIME switch to ON of T015S main
unit or press HOME button of T018S, after 60 seconds, then
Trigger wireless garage door open detector sensor (pull up and
put down detection rob will trigger it ), you will hear the main unit
sounds “DING DONG” chime or alert sound if signal is received
successfully, if not , change location is required.
5.Installation for up/down type garage door:
a.Before you install the sensor onto the garage door, make sure
the garage door is closed, the sensor assembly should be
mounted on one of the vertical supports of your garage door
near the bottom. When the door is closed, the detection rod
should be retracted. When the door is open, the detection rod
will be extended.
fig.7
( Fig.6)
3
Size:90X175mm
p/n:610-62501-000R
white paper print black words
FEATURES
• Detect garage door open out put wireless trigger signal
• Garage door sensor 3V lithium battery (CR2032) operation
(included)
• IP44 Water and weather resistant
• External trigger input terminal compatible wired magnetic sensor
for normal door
• Battery low indicator LED
• Wireless RF transmission distance about 30~40 meters (open
space)
DESCRIPTION OF COMPONENTS
1. Built-in detect sensor rod
2. Built-in detect sensor rod lock
3. External sensor terminal
4. Battery cover
5. Built-in sensor/external
sensor select switch
INSTALLATION
1.Remove the screw of garage door sensor battery cover, and open
the battery door.(Fig.1)
2.install a 3V lithium battery (CR2032 or equate type) for garage
door sensor, compartment make sure install with correct polarity. (Fig.2)
3. LEARN ID CODE TO MAIN UNIT
The wireless garage door open detector sensor compatible model:
625RX, T015S, T016S, T018S, 526L, must learn code to main
unit then use, the learning code can only be operated during
disarm mode. Follow these steps:
Learn ID code to 625RX wireless alert receiver unit:( Fig.3)
LOCK UNLOCK
2
5
1
3
4
(Fig.2)
(Fig.1)
LEARN
1
( Fig.3)
b.You can mount the sensor onto your garage door with
double-sided foam tape if the surface of your garage door is
smooth and clean enough to provide a good adhesive surface,
such surface can usually be found on a metal garage door.
Please ensure the surface is smooth and clean. the bottom of
the sensor should be 15mm above the ground.(fig.8)
c.For wooden garage doors, it is recommended to mount the
sensor with screws onto the garage door with screws provided.
fig.9
Note:
When the garage door is opening/closing, make sure the sensor
does not interfere with the safety reversing sensor or safety beam
sensor supplied with your existing garage door opener.
6.Installation for external magnetic sensor :
a.Remove the screw from battery compartment cover.
b.Connect the external magnetic sensor (included) to
terminal.(Fig.10)
c.Turn sensor select switch to EXT.(external)
d.Replace the battery cover and screw.
e.Pull up the detection rob to top and turn lock switch to
LOCK.(fig.11)
f.Choose a suitable location, use double-sided foam tape or
screws to mount the unit.
g.Mount the magnetic wired piece to the door frame and another
single piece to the door by using the double-side tapes (included)
(Fig.9)
LOCKLOCK UNLOCK
(Fig.8)
LOCKLOCK UNLOCK
15mm
(Fig.10)
(Fig.11)
LOCKLOCK UNLOCK LOCKLOCK UNLOCK
4
(Fig.7)
LOCKLOCK UNLOCK
Door closed
LOCKLOCK UNLOCK
Door open
and aligned the 2 sensor pieces to be flushed and “ ” facing “ ”
at no more than 15mm. (fig.12.13.14)
h.If you connect more than one sensor to unit,connect them in
series as shown below.(Fig.15)
i.Connect the sensor switch on door to the main terminal post
using the wire you just cut. (There is no polarity need to be
taken care of, any terminal will be fine, as long as the wires from
a loop)
OPERATION
After 60 seconds installed 3V battery, the unit will into standby
mode. Once the door/window opened will output wireless radio signal
and LED flash.
BATTERY LOW INDICATOR
When garage door sensor battery goes low, sensor unit battery
low led will flash once every second .
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits
for
a Class B digital device, pursuant to Part 15 of the FCC Rules.
These
limits are designed to provide reasonable protection against
harmful
interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
LOCKLOCK UNLOCK
(Fig.14)
(Fig.15)
5
1
2
3
Tape
610-62501-000R
garage door
LOCKLOCK UNLOCK
about 600mm
garage door
LOCKLOCK UNLOCK
about 600mm
(Fig.12)
(Fig.13)
OWNER'S MANUAL
Garage Open Alert
MODEL:625T
LOCKLOCK UNLOCK
installed and used in accordance with the instrucitons, may cause
harmful
interference to radio communications. However, there is no
gurantee
that interference will not occur in a particular installation.
If
this equipment does cuase harmful interference to radio or
television
reception, which can be determined by turning the
equipment
of f and on, the user is envouraged to try to correct the
interference
by one or more the of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from
that
to which the receiver is connected.
- Consult the dealer or an experienced technician for help.
This
device complies with Part 15 of the FCC Rules and with
RSS-210
of Industry Canada. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including
interference
that may cause undesired operation.
WARNING:
Changes or modifications not expressly approved by Lelux
could
void the user’s authority to operate the equipment.
6

Summary of content (1 pages)