Leica BLK2GO User Manual Version 0.
Introduction Purchase Congratulations on the purchase of the Leica BLK2GO. This manual contains important safety directions as well as instructions for setting up the product and operating it. Refer to "1 Safety Directions" for further information. Read carefully through the User Manual before you switch on the product. ☞ Product identification The content of this document is subject to change without prior notice. Ensure that the product is used in accordance with the latest version of this document.
Table of Contents 1 Safety Directions 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 3 4 5 7 5 6 6 6 7 10 10 11 11 13 15 Description of the System 16 2.1 2.2 2.3 16 16 17 System Components Container Contents Instrument Components User Interface 18 3.1 3.2 18 19 Power Button Instrument Status Power Supply 21 4.1 4.2 4.3 21 21 23 Battery and Charger Safety Charging Station Battery Operation 27 5.1 5.2 5.3 27 29 29 29 30 31 31 31 5.4 5.
7.9 8 Conformity to National Regulations 7.9.
1 Safety Directions 1.1 General Introduction Description The following directions enable the person responsible for the product, and the person who actually uses the equipment, to anticipate and avoid operational hazards. The person responsible for the product must ensure that all users understand these directions and adhere to them. About warning messages Warning messages are an essential part of the safety concept of the instrument. They appear wherever hazards or hazardous situations can occur.
1.2 Definition of Use Intended use • • • • • • • • Measuring horizontal and vertical angles. Scanning objects. Measuring distances. Capturing and recording images. Recording measurements. Computing with software. Remote control of product. Data communication with external appliances. Reasonably foreseeable misuse • • • • • Use of the product without instruction. Use outside of the intended use and limits. Disabling safety systems. Removal of hazard notices.
Person responsible for the product The person responsible for the product has the following duties: • To understand the safety instructions on the product and the instructions in the User Manual. • To ensure that it is used in accordance with the instructions. • To be familiar with local regulations relating to safety and accident prevention. • To inform Leica Geosystems immediately if the product and the application becomes unsafe.
NOTICE Removal of battery during operation or shutdown This can result in a file system error and data loss! 1942_002 Precautions: ▶ Do NOT remove the battery during operation of the instrument, or during the shutdown procedure. ▶ Always switch off the instrument by pressing the On/Off key, and wait until the instrument has shutdown completely before removing the battery.
WARNING Inappropriate mechanical influences to batteries During the transport, shipping or disposal of batteries it is possible for inappropriate mechanical influences to constitute a fire hazard. Precautions: ▶ Before shipping the product or disposing it, discharge the batteries by the product until they are flat. ▶ When transporting or shipping batteries, the person in charge of the product must ensure that the applicable national and international rules and regulations are observed.
WARNING Improperly repaired equipment Risk of injuries to users and equipment destruction due to lack of repair knowledge. Precautions: ▶ Only authorised Leica Geosystems Service Centres are entitled to repair these products. For the AC/DC power supply: WARNING Unauthorised opening of the product Either of the following actions may cause you to receive an electric shock: • Touching live components • Using the product after incorrect attempts were made to carry out repairs.
☞ National laws and local regulations could impose more stringent instructions for the safe use of lasers than IEC 60825-1 (2014-05) and IEC TR 60825-14 (2004-02). 1.6.2 Scanning Laser General The laser incorporated in the product produces an invisible beam which emerges from the rotating mirror.
tion and electrostatic discharges are present, and without causing electromagnetic disturbances to other equipment. WARNING Electromagnetic radiation Electromagnetic radiation can cause disturbances in other equipment. Precautions: ▶ Although the product meets the strict regulations and standards which are in force in this respect, Leica Geosystems cannot completely exclude the possibility that other equipment may be disturbed. CAUTION Use of the product with accessories from other manufacturers.
WARNING Use of product with radio or digital cellular phone devices Electromagnetic fields can cause disturbances in other equipment, in installations, in medical devices, for example pacemakers or hearing aids and in aircrafts. Electromagnetic fields can also affect humans and animals.
FCC-ID: RFD-BLK2GO IC: 3177A-BLK2GO This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, Including interference that may cause undesired operations. acc. To ICC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 Model: BLK2GO Art.No.
1.9 IC Statement, Applicable in Canada WARNING This Class (B) digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe (B) est conforme à la norme NMB-003 du Canada. Canada Compliance Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licenceexempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2.
2 Description of the System 2.1 System Components System components a b c a d b e c d e f f 19492_001 2.
2.
3 User Interface 3.1 Power Button Power button a a 19556_001 Power button Power button when the BLK2GO is THEN Press and hold the button >5 sec. off. The BLK2GO switches on and the LED starts blinking yellow. Press and hold the button for 2 sec. on and ready. The LED is continuous green. The BLK2GO starts recording and the LED starts blinking green. Press and hold the button >5 sec. on and ready. The LED is continuous green. The BLK2GO switches off immediately. Hard shut down.
3.2 Instrument Status Instrument status The ring-shaped LED lights up in different colours and lighting intervals to show the operation states of the BLK2GO. 19558_001 Operation mode Description Details Colours • • • • • Green Yellow Red Blue Rainbow Lighting intervals • • • • • • Continuous Blinking Pulsating 3 pulses, every 30 seconds 1 pulse Rotating LED colour Lighting interval Instrument status none The BLK2GO is off or in Power Safe mode.
LED colour Firmware update mode LED colour ☞ 20 Lighting interval Instrument status pulsating The BLK2GO is in recording state. blinking The BLK2GO is starting, switching off or something to be notified or action needed. pulsating Message to be notified or problem. continuous Critical problem or major failure. Contact a Leica Geosystems authorised service centre for further investigation. 1 pulse Picture from the detail camera successfully taken.
4 Power Supply 4.1 Battery and Charger Safety General Use the batteries, chargers and accessories recommended by Leica Geosystems to ensure the correct functionality of the instrument. First-time use/ charging batteries • The battery must be charged before using it for the first time because it is delivered with an energy content as low as possible. The permissible temperature range for charging is from 0 °C to +40 °C/ +32 °F to +104 °F.
Charger components a b c d 19535_001 a b c d DC input Battery bay with charging function Battery status LED Battery connector LED indicators 19536_001 LED indicator Power supply 22 ☞ Status Description Off No activity. Solid green The battery is fully charged. Blinking orange The battery is charging. Solid red Failure. Refer to "Troubleshooting". The charger GKL821 is only allowed to be operated with its own AC/DC power adapter. The AC/DC power adapter is part of the delivered package.
0 V 120 V 220 V 230 V 230 V 19541_001 Input voltage: 100-240 V AC Troubleshooting If an error occurs, the LED indicator of the related battery bay lights constantly red. 19542_001 Remove and insert the battery again. Make sure that the battery is correctly positioned in the battery bay. If the failure persists, the charger must be sent to a Leica Geosystems authorised service centre. 4.3 Battery NOTICE Always shut down the instrument before removing the battery.
Remove and insert the battery step-by-step Remove the battery 2 1 19544_001 1. Slide the locking mechanism of the battery to the open position. 2. Lift the battery and remove it from the compartment. Insert the battery 1 2 19545_001 1. Attach the upper side of the battery to the compartment at an angle and then lower the bottom side. Ensure that the battery contact slots are facing inwards. ☞ 2.
Battery status Press the status button to check the battery status. 19546_001 Status LED Battery status 0%-30% 19547_001 31%-60% 19548_001 61%-90% 19549_001 91%-100% 19550_001 Charge batteries step-by-step ☞ The GKL821 can charge 1 to 4 batteries at a time depending on requested battery charging current. If inserting more than two batteries, charging priority is given by the order of when the batteries were inserted. 1 5 2 4 6 3 19543_001 Power Supply 1.
3. Insert the battery with the contact slots facing downwards. The LED of the battery bay blinks orange process. Refer to "LED indicators". 4. 5. If the LED of the battery bay lights solid green the battery is fully charged. Disconnect the charger plug from the DC input of the charger. Unplug the AC/DC power adapter from the AC power source. Carefully pull the battery upwards. The LED indicator of the battery bay is off 26 indicating the charge .
5 Operation 5.1 Operation - Getting Started Stand-alone operation step-by-step 2 1 3 4 5 REC REC 19565_001 Operation 1. Press the power button to turn on the BLK2GO. 2. The BLK2GO is starting. The ring-shaped LED is blinking yellow. 3. If the ring-shaped LED is continuous green, the BLK2GO is ready for operation. Press the power button to start recording. 4. Recording starts. The ring-shaped LED is blinking green. 5. The recording is finished. The ring-shaped LED is continuous green.
Operation with computing device connection step-by-step 2 3 1 Connect 4 5 REC 19566_001 1. Press the power button to turn on the BLK2GO. 2. The BLK2GO is starting. The ring-shaped LED is blinking yellow. 3. If the ring-shaped LED is continuous green, the BLK2GO is ready for operation. Connect the computing device with the BLK2GO. 4. Press the power button on the BLK2GO to start the recording. The ring-shaped LED is blinking green. 5. Use the computing device for immediate feedback. 1.
5. Start the app and connect the instrument. For further information, refer to the help menu in the app. ☞ 5.2 Imaging Description The BLK2GO can collect two different types of images: • A panoramic image using 3 calibrated panoramic cameras • A high resolution image using the detail camera Camera position a b Detail camera Panoramic camera a b b 19572_001 5.3 Scanning 5.3.
Dirt on the dome Due to the encapsulated mirror design, the mirror is protected against direct contact. But dirt on the dome such as a layer of dust, condensation or fingerprints may cause considerable measuring errors. 5.3.2 Troubleshooting Basic troubleshooting Advanced troubleshooting Troubleshooting in operation mode Troubleshooting support contacts 30 Problem Possible Cause(s) Suggested Remedies Missing points in scan. Dust, debris or fingerprints on the dome.
5.3.3 Field of View (FoV) Scanning laser field of view 90° a 0° 360° b 360° 0° 30° 30° 19574_001 a b Vertical field of view: 300° Horizontal field of view: 360° 5.4 Data Transfer Description Raw data can be transferred from the BLK2GO to a computing device using a wireless connection. Connect 19576_001 5.5 Cooling System Description The core of the cooling system is a 10-blades impeller driven by a high-speed motor.
6 Care and Transport 6.1 Maintenance ☞ For units that are exposed to high mechanical forces, for example through frequent transport or rough handling, it is recommended to carry out test measurements periodically. 6.2 Transport Transport in the field When transporting the equipment in the field, always make sure that you carry the product in its original container. Transport in a road vehicle Never carry the product loose in a road vehicle, as it can be affected by shock and vibration.
6.4 Cleaning and Drying Damp products Dry the product, the transport case, the foam inserts and the accessories at a temperature not higher than 40°C /104°F and clean them. Remove the battery cover and dry the battery compartment. Do not repack until everything is completely dry. Always close the mission bag when using in the field. Housing parts of product and accessories • • Charger and AC/DC power supply Use only a clean, soft, lint-free cloth for cleaning.
Switch off instrument and remove the battery. Washing hands is necessary in order to avoid grease on the cleaning tissue. Better, use gloves to avoid finger oil on the glass. Then use the wet lens cleaning tissue (Green Clean LC-7010) until there is only a thin film of detergent visible. After that use the dry lens cleaning tissue (Green Clean LC-7010) to remove any remaining detergent. If any smears from cleaning are visible against back light, repeat the procedure.
The following steps 4. to 6. shall not be done in the same room as the mounting/dismounting takes place. ☞ 4. Clean the fine filter cartridge with fresh clean compressed air, for example with compressed air spray. Clean it from the inside of the fine filter cartridge to the out and not the vice-versa. 5. Clean the coarse suction filter with fresh clean compressed air, for example with compressed air spray. Clean it from the inside out and not the vice-versa. 6.
7 Technical Data 7.1 General Technical Data of the Product Storage and communication Detail camera Panoramic cameras Function Value Internal storage 6 hours of scanning Communication Integrated 802.11 b/g/n/ac WLAN with MIMO.
7.4 BLK2GO power supply Electrical Data Internal battery 7.2 V DC; one internal battery provided with the instrument. Battery operating and charging times Internal battery Value Operating time >30-40 minutes operating, continuous use at room temperature. Charging time Typical charging time with GKL821 charger is 2.5 hours at room temperature. 7.5 Environmental Specifications 7.5.
Protection against water, dust, sand and humidity Type Protection Battery IP54 (IEC 60529) Dust protected Protection against splashing water from any direction. Humidity max. 95% non condensing. Charger and AC/DC power supply 7.6 Only operate in dry environments, for example in buildings and vehicles. Dimensions Dimensions 7.
Additional accessories • • • 7.9 Conformity to National Regulations Conformity to national regulations Additional batteries GEB821 Fine filter cartridge Cover sheet • FCC Part 15 (applicable in US) • Hereby, Leica Geosystems AG declares that the radio equipment type BLK2GO is in compliance with Directive 2014/53/EU and other applicable European Directives. The full text of the EU declaration of conformity is available at the following Internet address: http://www.leica-geosystems.com/ce.
☞ 40 Damaged or defective batteries are prohibited from being carried or transported onboard any aircraft. Therefore, ensure that the condition of any battery is safe for transportation.
8 Software Licence Agreement Software Licence Agreement This product contains software that is preinstalled on the product, or that is supplied to you on a data carrier medium, or that can be downloaded by you online according to prior authorisation from Leica Geosystems.
xxxxxx-0.9.0en Original text (xxxxxx-0.9.0en) Printed in Switzerland © 2019 Leica Geosystems AG, Heerbrugg, Switzerland Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Switzerland Phone +41 71 727 31 31 www.leica-geosystems.