Installation Instructions

No: 341278 4/20
radiant
®
WZ3RL10 Smart Switch, Zigbee 3.0, Incandescent, Halogen, Incandescent: 1800W
Resistive: 120VAC, 60Hz, 15A; Standard + Electronic Ballast: 15A; Motor: 1/2 HP
Interrupteur intelligent WZ3RL10, radiant® , module Zigbee 3.0, incandescent, halogène, incandescent : 1800 W
Résistif : 120 V c. a., 60 Hz, 15 A; ballast standard/électronique : 15 A; moteur : 1/2 HP
radiant® Interruptor inteligente WZ3RL10, Zigbee 3.0, incandescente, halógeno, Incandescente: 1800 W
Resistivo: 120 VCA, 60 Hz, 15 A; Balasto estándar + electrónico: 15 A; Motor: 1/2 HP
Installation Instructions • Notice d’Installation • Instrucciones de Instalación
Catalog Number(s) • Numéro(s) de Catalogue • Les Numéros de Catalogue : WZ3RL10
Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China
1-POLE
Gr
ound
WHITE
HO
T
OFF
ON
OFF
ON
OFF
ON
Load
Red
Green
Bare
Supply
“Hot”
WZ3RL10
Smart Switch Zigbee 3.0
BEFORE YOU START
Review this guide in its entirety. Consult an electrician with any questions or
if you are unsure of your abilities.
Warning: Incorrect installation could result in death, serious injury, and/or
damage to your home or devices.
Caution: To reduce the risk of injury and/or overheating and damage to
other equipment:
For dry, indoor use only.
Do not use to power medical equipment – not
suitable as a disconnecting means.
Do not use with loads exceeding the device
load rating.
Connect the smart switch to a 120 VAC, 60 Hz power source ONLY.
Always use copper wire to install the smart switch & follow all applicable
local & national electrical codes.
WHAT YOU NEED
Required:
Phillips-head screwdriver
Flat blade screwdriver
You May Also Need:
Voltage tester, pliers, wire cutter, wire stripper, electrical tape, flashlight,
wiring leads (included), and wire nuts (included).
INSTALLATION & SETUP
1. Turn off power to device at circuit breaker
Flip existing light switch multiple times to confirm power is o󰀨.
NOTE: Ensure power is o󰀨 to all devices in
electrical box.
2. Remove existing device
Check for the following wires:
a. HOT or LINE: Receives power from the circuit box. Referred to as “hot”
for the purpose of this guide. Do not touch or let “hot” wire contact
other wires.
b. LOAD: Directs power to your light(s).
c. NEUTRAL: Creates a path to return current to the power source when
the device is o󰀨. Required for your switch installation.
d. GROUND: Provides a safe path for electricity in the even of a short
circuit.
3. Wire Smart Switch
Use the wire nuts provided to secure the wires together.
a. Connect the WHITE neutral wire on the switch to the neutral wires in
the box, using the red wire nut.
b. Connect the LOAD wire on the switch to the load wire(s) in the box.
c. Connect the HOT wire on the switch to the hot wire(s) in the box.
d. Connect the GREEN ground wire on the switch to the ground wire(s) in
the box.
e. If the light is controlled with the only switch, use a wire nut to cap the
YELLOW traveller wire on the device and proceed to step 4.
4. Secure Smart Switch
a. Fold the wires into electrical box, taking care not to pinch a wire.
b. Use included screws to secure smart switch to electrical box. Do not
fully tighten the screws.
5. Test The Smart Switch
NOTE: See getting to know your switch section for feature details.
Turn the power back on at the circuit breaker, press switch to turn light on/
o󰀨.
This device is designed to work with a Zigbee hub. Press the EZ button, the
LED indicator will blink magenta to indicate commissioning mode. Follow the
instructions from your hub to commission the device. If the switch is enrolled
successfully, the LED will stop blinking.
TROUBLESHOOTING TIP: If the device is not powering check wiring to
determine if you have reversed the “HOT” and “LOAD” wiring.
6. Attach Wall Plate
a. Use the sub-plate screws (provided) to secure the sub-plate to the
smart switch.
b. Tighten device screws to secure smart switch to the electrical box.
c. Angle the UP end of the wall plate over the top edge of the sub-plate.
Push the screwless wall plate down and in until it “snaps” into place
over the sub-plate.
NOTE: To remove the wall plate, place the tip of
a flat blade screwdriver into the slot under the
wall plate and twist gently.
7. Set Up Your System
For more information on this product please see
this link, or scan the QR code.
https://www.legrand.us/radiant/products/smart-
lighting/wz3rl10wh.aspxg
G
GETTING TO KNOW YOUR SWITCH
Item Name Description
1 Paddle
Switch
Press the top of the
paddle to turn light on
and the bottom of paddle
to turn light o󰀨.
2 LED Loca-
tor Light
Indicates the current
state of device. Refer
to “LED Locator Light
Explanations” for detail.
3 EZ Button Used to start commis-
sioning.
LED Locator Light Explanations
State of Light Explanation
Solid White Lit when load is o󰀨.
Solid Red Factory reset, not in network.
Blinking Magenta Device is attempting to connect to the network on all channels
except 26.
Solid Magenta Device in network, temporarily open.
Reset To Factory Default
Deleting a device from the app will reset it to factory defaults.
To manually reset the device to factory defaults press and hold the EZ
button for 10 seconds until you see the LED blink red then release. The LED
will change to solid red when the reset is complete.
SPECIFICATIONS
Deleting a device from the app will reset it to factory defaults. To manually
reset the switch to factory defaults press and hold the O󰀨 (-) button for 10
seconds until you see the LED blink then release.The device will reset in
about 20 seconds after release.
Load Rating
Resistive 120 VAC, 60 Hz, 15 A
Incandescent/Halogen 1800 W
Ballast 15 A standard/electronic
Motor
1
/
2
HP
Legrand reserves the right to change specifications without notice.
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
VOLTAGE
TESTER
Load
Supply
“Hot”
1 2
1-POLE
Gr
ound
WHITE
HO
T
OFF
ON
OFF
ON
OFF
ON
Load
Red
Green
Bare
Supply
“Hot”
THIS SIDE OUT
MOUNT OVER DEVICE
THIS SIDE OUT
MOUNT OVER DEVICE
THIS SIDE OUT
MOUNT OVER DEVICE
a b c
FCC COMPLIANCE &RQWDLQVFCC ID: 2AU5D982057 IC: 25764982057 HVIN: 982057
CAUTION: Changes or modifications not expressly approved could
void your authority to use this equipment. This device complies
with Part 15 of the FCC Rules. Operation to the following two
conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
To comply with FCC and other RF exposure requirements, please
maintain a distance of Pm between the charger and your body
when in use.
INDUSTRY CANADA – This device complies with Industry Canada
license-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
MISE EN GARDE : Les changements ou les modifications
qui ne sont pas expressément approuvés pourraient annuler
votre autorisation d’utiliser ce matériel. Le présent appareil est
conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes : (1) l’appareil ne doit pas produire
de brouillage, et (2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Afin de se conformer à la FCC et aux autres exigences visant
l’exposition aux radiofréquences, conserver une distance de 10
mm entre le chargeur et votre corps pendant l’utilisation.
PRECAUCIÓN: Los cambios o modificaciones que no sean
expresamente aprobados podrían anular su autoridad para usar
este equipo. Este dispositivo cumple con la Parte 15 de las
Reglas de la FCC. Operación bajo las siguientes dos condiciones:
(1) Este dispositivo no debe provocar interferencia dañina,
y (2) este dispositivo debe aceptar cualquier interferencia
recibida, incluso interferencia que pueda provocar una operación
no deseada.
A fin de cumplir con la FCC y otros requisitos de exposición a
frecuencia de radio, mantenga una distancia de 10 mm entre el
cargador y su cuerpo cuando esté en uso.
2
3
1
INSTRUCTIONS EN FRANÇAIS
AVANT DE COMMENCER
Passer l’ensemble de ce guide en revue. En cas de question ou
d’incertitude concernant vos capacités, consulter un électricien.
Mise en garde : Une installation inappropriée pourrait entraîner la mort,
des blessures graves et (ou) des dommages à votre domicile ou à vos
dispositifs.
Attention : Pour réduire le risque de blessures et (ou) de surchau󰀨e et de
dommage à d’autre matériel :
Caution: To reduce the risk of injury and/or overheating and damage to
other equipment:
• Pour usage intérieur dans un endroit sec seulement.
• Ne pas utiliser pour alimenter du matériel médical; ne convient pas comme
moyen de débranchement.
• Ne pas utiliser avec des charges dépassant la capacité de charge du
dispositif.
• Connecter l’interrupteur intelligent UNIQUEMENT dans une source
d’alimentation de 120 V c. a., 60 Hz.
• Toujours utiliser un fil de cuivre pour installer l’interrupteur intelligent et
respecter tous les codes de l’électricité locaux et nationaux applicables..
CE DONT VOUS AVEZ BESOIN
Obligatoire :
• Tournevis cruciforme
• Tournevis à tête plater
Autres éléments pouvant être requis :
Testeur de tension, pinces, pince coupe-fils, pince à dénuder, ruban isolant,
lampe de poche, fils de connexion (inclus) et connecteurs de fils (inclus)
INSTALLATION ET CONFIGURATION
1. Mettre le dispositif hors tension au disjoncteur et appuyer plusieurs
fois sur l’interrupteur actuel pour conrmer que le courant est coupé.
REMARQUE : S’assurer que tous les dispositifs du boîtier électrique sont
hors tension.
2. Retirer le dispositif actuel
Vérifier les fils suivants :
a. FIL CHARGÉ ou FIL DE LIGNE : Reçoit le courant du boîtier de
circuits électriques. Appelé fil « chargé » aux fins du présent guide.
Ne pas toucher aux fils « chargés » ni les laisser entrer en contact
avec d’autres fils.
b. FIL DE CHARGE : Dirige le courant vers la ou les lumière(s).
c. FIL NEUTRE : Crée un chemin pour renvoyer le courant à la source
d’alimentation lorsque le dispositif est hors tension. Requis pour
l’installation de votre interrupteur.
d. Mise à la terre : Fournit un chemin sécuritaire à l’électricité en cas de
court-circuit.
3. Relier les ls de l’interrupteur intelligent
Utiliser les connecteurs de fils fournis pour fixer les fils ensemble.
a. Connect the WHITE neutral wire on the switch to the neutral wires in
the box, using the red wire nut.
b. Connect the LOAD wire on the switch to the load wire(s) in the box.
c. Connect the HOT wire on the switch to the hot wire(s) in the box.
d. Connect the GREEN ground wire on the switch to the ground wire(s) in
the box.
e. If the light is controlled with the only switch, use a wire nut to cap the
YELLOW traveller wire on the device and proceed to step 4.
4. Fixer l’interrupteur intelligent
a. Plier les fils dans le boîtier électrique en prenant soin de ne pas les
pincer.
b. Utiliser les vis fournies pour fixer l’interrupteur intelligent au boîtier
électrique. Ne pas serrer complètement les vis.
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
VOLTAGE
TESTER
Load
Supply
“Hot”
1 2

Summary of content (2 pages)