We build your success in IoT.
Motion Sensor Pet immunity Quick Start Guide 1. Product Introduction The Motion Sensor lets you know when movement is detected in a certain area and can trigger different actions in response to that movement (or lack of movement). It supports the pet immunity up to 80 lbs. This sensor integrated Z-Wave communication module to connect with Z-Wave gateway, and this device can be adapted to EU(868.42Mhz) or US(908.42MHz).
Bracket Reset button Button: Short press reset button into learning mode, then the sensor can inclusion or exclusion from the ZWave network. Hold the key for 5s to reset the sensor, after reset, Sensor will send “Device_Reset_Locally” to the main controller and exclude from the Z-Wave network when the Button is released, this procedure will reset the Sensor to factory default.
Specification Detection angle 80 degrees Detection distance 8 meters / 26.25 feet Pet immune 80 lbs (36 kgs) Mounting height 6.23 ft. to 7.55 ft. (1.9m to 2.3m) Light sensor 20 lux for day/night(bright/dark) Protocol Z-Wave 908.42MHz (US) 868.42MHz(EU), 868.40MHz,868.42MHz, 869.85MHz 921.
3. Features/Capabilities: Supports pet immunity up to 80 lbs (36 kgs) Use PIR & Fresnel lens technology Easy installation with bracket Low battery alarm Equipped with an anti-tamper switch that reports any tampering 4. Installation Position and Notes 1. Installation position should be chosen at the area which the bass-by will be across, try to make the bassby in the detection area as below.
Side view Top view 2. Do avoid installation near air-conditioner, electric fans, refrigerators, ovens or other places where temperature easy change. 3. In order not to affect the detecting result, there should be no object in front of the produces lens. 4. Building (such as the wall) will shorten the distance of wireless communication. 5. This device can be mounted on the wall only, it cannot be installed on the ceiling. 5.
6. Product Usage Function of Action Button: 6.1 All functions of each trigger: Function Of Action Trigger Power on Description In the network: Send Battery report and Wake up notification, the LED turn on within 1 second. Not in the network: Only the LED turn on within 5 second. Short press button one time Short press button three time Add the Motion Sensor into the Z-Wave network: 1. Power on your Motion Sensor, and let your Z-Wave controller into add/inclusion mode. 2.
Motion is triggered In the network: Send Notification report and Sensor multilevel report and Basic set (Setup configuration parameter 0x0E to 0x01), and the LED will be blink 0.5 second. Not in the network: NOP. Tamper switch is triggered In the network: Send Notification report, and the LED will be blink 0.5 second. Not in the network: Only the LED will be blink 0.5 second. 6.2 Caution: This device complies with Part 15 of the FCC rules.
Installer Icon Type 0x0C06 (ICON_TY PE_SPECIFIC_SENSOR_NOTIFICATION_A CCESS_CONTROL) User Icon Type 0x0C06 (ICON_TY PE_SPECIFIC_SENSOR_NOTIFICATION_A CCESS_CONTROL) Association Command Class Motion Sensor supports 2 association groups and max 5 nodes for each group.
Wake Up Interval Capabilities Report CC Parameter Value WAKEUP_PAR_DEFAULT_SLEEP_TIME 0x0E10 WAKEUP_PAR_MAX_SLEEP_TIME 0x28DE80 WAKEUP_PAR_MIN_SLEEP_TIME 0x3C WAKEUP_PAR_SLEEP_STEP 0x3C Manufacturer Specific Report Parameter Value Manufacturer ID 1 0x03 Manufacturer ID 2 0x00 Product Type ID 1 0x03 Product Type ID 2 EU 0x00 NA 0x01 Product ID 1 0x00 Product ID 2 0x26 Configuration Set Command Class Command Format 7 6 5 4 3 2 1 0 Command Class = COMMAND_CLASS_CONFIGURATION Co
0x0C (12) 0x0D (13) 0x0E (14) 0x0F (15) Setup the PIR detects functionality. 0 = Disable the PIR 1 = Enable the PIR Setup the wait time of PIR for clear the motion. Valid values: 0x05~0x3BC4 When the Motion Sensor is triggered, if this parameter is 0x01 then it will send Basic set command to group 1. 0 = Don't send. 1 = Send. PIR triggers the correspondence between the value of the Basic set and the PIR state.
FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment.