a module solution provider Jorjin Certification Sample User Manual WG7831DELF
a module solution provider Software lnstallation (1) Executive TI Wireless Tools HDK2.0.
a module solution provider Transfer Description - 1 Jumper insertion position for the red box
a module solution provider Transfer Description - 2 BT Test Connection USB WIFI Test Connection USB
a module solution provider Transfer Description - 3 BT ON : R28 BT OFF : R31 WIFI ON : R29 WIFI OFF : R32
a module solution provider WG7831DELFA Reference Schematics
a module solution provider COM PORT Set 1. Install TI Wireless Tools 2. When the hardware is connected to the PC, it is possible to find the port number for communication. Under the Device Manager, select Ports (Com & LPT). 3. Run “RTTT” to start WiFi test software. The USB ports are Com7 and Com8. Normally, the first port, Com7, is the communication port, while the next port, Com8, is the debug port.
a module solution provider WIFI RTTT SET – 1 (Set time the first operation) (1)Select WL18XX (2) SET COM PORT (3) SET Baud Rate ( 921600 ) (4) SET Board Type : HDK
a module solution provider Set path WIFI RTTT SET – 2 (Set time the first operation) Firmware file : C:\Program Files (x86)\Texas Instruments\Wireless Tools\RTTT\Clients\TrioScope\18xx\wl18xx-fw-mc.bin INI file : C:\Program Files (x86)\Texas Instruments\Wireless Tools\RTTT\Clients\TrioScope\18xx\INI Files\WL8_INI_2ANT.ini TS DLL : C:\Program Files (x86)\Texas Instruments\Wireless Tools\RTTT\Clients\TrioScope\18xx\ts18x.
a module solution provider WIFI RTTT SET – 3 Press Connect PC Will change of connect
a module solution provider WIFI RTTT SET – 4 Press “Load” Read Firmware Read Success
a module solution provider WIFI RTTT SET – 5 Select TX or RX SET channel Select Channel BW Set ANT Select Modulate and data rate SET Power Start TX ON/OFF
a module solution provider WIFI RTTT SET – 6 NOTE: Chain 1 Express DUT ANT2, Chain 2 EXpressDUT ANT1 Select dBm, Do not select dBPsat Click SoC Limits, Power Limit Will be locked the Dut settings.
a module solution provider BT HCI Set – 1 (Set time the first operation) (1) Execution HCI_Tester (2) Select View Options (3) SET COM PORT and Baud Rate
a module solution provider BT HCI Set – 2 (Set time the first operation) (1) Add NEW XML檔
a module solution provider BT HCI Set – 3 (Set time the first operation) (1) Select NEW (3) Select “ServicePack_18xx_3P1.
a module solution provider BT HCI Set – 4 (1) File Open, Select “ServicePack_18xx_3p1_switch3w_Xtal.
a module solution provider (1) (2) (3) (4) (5) BT HCI Set – 5 Select File New, CON_TX_TESTER.
a module solution provider CON_TX_TESTER.
a module solution provider CON_TX_TESTER.
a module solution provider The transmitter module certification label 「本產品內含射頻模組: TTTTcccczzzzAI
a module solution provider WARNINGS, RESTRICTIONS AND DISCLAIMERS Your Sole Responsibility and Risk. You acknowledge, represent and agree that: 1.You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes. 2.
a module solution provider WARNINGS, RESTRICTIONS AND DISCLAIMERS 6. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
a module solution provider WARNINGS, RESTRICTIONS AND DISCLAIMERS 9. End Product Labeling When the module is installed in the host device, the FCC/IC ID label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily re-moved.