Quick Reference Guide

Wireless Charger
10 Watts Max.)
USB Type-C Charger
(30W & 60W Max.)
USB Type-A Charger
(DC 5V 2.1A and 2.4A Max.)
Tamper-Resistant AC Receptacle
(AC 120V 8A Max. per receptacle)
Plug in to a grounded
AC outlet only
Kensington® NanoSaver™
Lock Slot
Please contact with National Lighting Corp. at (888)428-6886 or www.NationalLighting.com for more information.
Scepter Quick Reference Guide Version: 1.0
Model: DOCK163129W
Rating: AC 120V, 60Hz, 12A
Specifications: 3 x Qi wireless rapid chargers,
3 x Tamper-resistant AC receptacles,
2 x USB Type-A charging ports,
1 x 30W USB Type-C charging port,
1 x 60W USB Type-C charging port.
CAUTION: To prevent the risk of fire and electric shock,
please be sure to read all instructions before installing
or using this unit.
DOCK-1600 SERIES
QUICK REFERENCE GUIDE
Storable temperature (non-operating): -30 °C to 70 °C Typical value: 25 °C
Operating temperature Limits: -20 °C to 40 °C Typical value: 25 °C
Storage Humidity (non-operating): 5% to 90% RH (Non condensation)
Operating Humidity Limits: 10% to 90% RH (Non condensation)
Storage Altitude (non-operating): 0 to +2000m above the sea level
Operating Altitude (non-operating): 0 to +2000m above the sea level
Supports USB PD3.0 charging standard
Support PPS charging standard
Support QC2.0 / 3.0 charging standard
5.0 Support USB DCP BC1.2 charging standard
Support Apple 5W / 10W / 12W USB charging standard
Support AFC charging standard
Supports FCP charging standard
USB output charging can reach 60W maximum.
Wireless charging module can wirelessly charge mobile phones at a distance of 0-6mm. The maximum power can reach 10W
- Indoor use only
- Do not use with extension cord(s)
- Do not plug a device or devices into receptacles that exceed a total of 9.7A (1164 watts)
- Do not open or attempt to open the unit for any reason
WARNING:
To reduce the risk of fire, electric shock or injury to persons:
FCC Statement:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies
with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
ISED RSS Warning/ISED RF Exposure Statement
ISED RSS Warning:
This device complies with Innovation, Science and Economic
Development Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'ISED applicables
aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set
forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the
radiator & your body.This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
Le rayonnement de la classe b repecte ISED fixaient un
environnement non contrôlés. Installation et mise en œuvre de
ce matériel devrait avec échangeur distance minimale entre 20
cm ton corps.Lanceurs ou ne peuvent pas coexister cette
antenne ou capteurs avec d’autres.

Summary of content (1 pages)