LUX Led Light Meter LM-50KL HB4LM50KL001 .
CONTENTS 1. Description .................................................... 1 2. Accessories .................................................. 1 3. Safety Precaution ......................................... 1 4. Preface ......................................................... 2 5. General Specifications .................................. 3 6. Electrical Specifications ................................ 4 7. Operation ...................................................... 5 8.
LM-50KL 1. Description Measures light from visible luminaries equipped with white light LED, fluorescent, metal halide, high-pressure sodium and incandescent sources. 2. Accessories 1 1 1 1 3. Meter 9 Volt battery Manual Carrying Case Safety Precaution CAUTION Be extremely careful for the following conditions while measuring Do not operate the meter under the environment with explosive gas (material), combustible gas (material) steam or filled with dust.
LM-50KL 4. Preface The flux of light received in a unit area of a certain side being shown is popularly known as illumination. The measuring unit in both United Kingdom and America is known as footcandles light, but in Europe it is also known as meter candlelight. One foot-candles light is the illumination of light that falls on one side which is one foot away from a one foot-candlelight and exactly intersecting with the light.
LM-50KL 5. ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ General Specifications Overload Indication: LCD screen will show “OL” on the upper left-hand corner. Low battery Indication” ”. Sampling Rate: 2.5 times per second for digital display. Spectral response close to CIE luminous spectral efficiency. Cosine Angular corrected. According to JIS C 1609:1993 and CNS 5119 general A class Specifications. Measuring lights source: LED white light and all visible light.
LM-50KL 6. Electrical Specifications Display of LM-50KL 2000 count, maximum display 1999 Sensor Measuring Range of Silicon photodiode and filter 200,2000, 20000,200000 Lux 20,200,2000,20000 Footcandles Accuracy ±3% (Calibrated to standard incandescent lamp 2856∘K) 8% other visible light source Angle deviation from cosine characteristics Power Supply 10 ○ ±0.
LM-50KL 7. Operation 1. 2. Press the “ ” button to turn power on or off. Remove sensor cap and place the sensor perpendicular to the light. Select LUX or FC. When “OL” is shown on the LCD screen, press 3. 4. 5. the button for useable reading. If you want to keep the reading value on the LCD screen permanently after testing, press the 6. “ ” button. When done testing, replace the sensor cover to protect the filter and sensor.
LM-50KL ⚫ M-H (LM-50KL) Press button to Lockup data maximal value of measure data. ⚫ LX/FC (LM-50KL) Illuminance Lux or Foot candle measuring unit button.
8. LM-50KL Instrument Description of LM-50KL 1. 2. 3. 4. 5. 6. 7. 8. Display (LCD). MAX HOLD. Power Button: ON/OFF. Lux/Fc button DATA HOLD button. Range button. Photo detector. Zero Adjustment.
LM-50KL 9. ⚫ ⚫ ⚫ Attention Set for referring the testing of source of light is located at the right top end (0 degree) of the light sensor ball plane. When the meter is not in use, please keep the cap of the light sensor in its place to avoid the photo diode from wearing out. When it is not in use for a long time, please take the batteries away. And avoid keeping it in a place of high temperature and humidity.
LM-50KL 10.
LM-50KL Schools Illuminance(lux) 1500 to 300 750 to 200 300 to 75 75 to 30 10 to 2 11. Place Precision drawing or drafting, precision experimenting, library Classrooms, library reading rooms, staff rooms, gymnasia Lecture halls, assembly rooms, locker rooms, corridors, stairways and restrooms Warehouses and emergency stairways School passages Battery Replacement WARNING If the symbol ” ” appears on the LCD, please replace the battery immediately Remove the battery cover Replace the battery.