User & Installation Manual LT-3100S GMDSS Satellite Communications System Document Number: 95-101817 Rev. 1.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 This Document is of © copyright to Lars Thrane A/S. It contains proprietary information, which is disclosed for information purposes only. The contents of this document shall not in whole or in part be used for any other purpose without prior permission from Lars Thrane A/S. Disclaimer Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Lars Thrane A/S.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Safety Instructions for the Installer The following safety instructions must be observed during all phases of operation, installation, service and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture and intended use of the equipment. Lars Thrane A/S assumes no liability for the customer's failure to comply with these requirements.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Safety Instructions for the Operator The following safety instructions must be observed during all phases of operation, installation, service and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture and intended use of the equipment. Lars Thrane A/S assumes no liability for the customer's failure to comply with these requirements.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 IMPORTANT – FCC Compliance Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 About this manual Intended readers This is a User & Installation Manual for LT-3100S GMDSS Satellite Communications System, or LT-3100S GMDSS System. The manual is primarily intended for installers and service personnel. Personnel installing or servicing the system should be professionals with technical expertise, properly trained, and likewise authorized. All safety instructions and guidelines in this manual must be observed.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Software versions This manual is applicable to the following software: Software Versions Description LT-3100S GMDSS System Version 1.01 Table 1: Software Versions Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Record of Revisions Rev. Description Release Date 1.00 Original document. November 4, 2019 PT 1.01 GMDSS user functions November 19, 2019 KK, PT 1.02 Added FCC compliance notes, Part 80 (page iv) January 8, 2020 Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Table of Contents Introduction ...................................................................................................................................................... 1 Unpacking (in-the-box) ..................................................................................................................................... 2 Inspection .........................................................................................................
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Non-priority messaging .............................................................................................................................. 43 Position of vessel ........................................................................................................................................ 44 Bridge Alert Management ..........................................................................................................................
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Introduction Introduction Congratulations on your purchase of the LT-3100S GMDSS Satellite Communications system! The LT-3100S GMDSS Satellite Communications System is a maritime satellite communication product from Lars Thrane A/S. The LT-3100S GMDSS system is designed for the professional market (deep sea, fishing, and workboats), but can be used for the leisure market as well.
LT-3100S GMDSS User & Installation Manual Rev. 1.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Accessories Accessories GMDSS parts The following GMDSS parts are not part of the basic system and must be ordered separately: • • • 51-101814 LT-3140S Interface Unit 51-101815 LT-3150S Alarm Panel (incl. 25m cable) 51-101816 LT-3160S Printer Adapter (incl. 25m cable) SSAS parts The following SSAS parts are not part of the basic system and must be ordered separately: • • 91-102073 SSAS Alert Button (incl. 50m cable) 91-102074 SSAS Test Button (incl.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 System Overview System Overview The LT-3100S GMDSS Satellite Communications System is a standalone communication product, which is using the Iridium® satellite constellation. The LT-3100S GMDSS system is working on the new Iridium® NEXT satellites. An overview of the LT-3100S GMDSS system is illustrated in Figure 1. Figure 1: LT-3100S GMDSS system - components and interfaces.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 NOTE: Lars Thrane A/S System Overview The LT-3100S GMDSS system will be released to customers with the initial software version 1.01. Software version 1.01 includes support for all GMDSS services. Additional none GMDSS services might be added in later software releases. Please contact Lars Thrane A/S for details about future software releases and features: support@thrane.eu www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting Installation and Mounting LT-3110S Control Unit The LT-3110S Control Unit is the master unit in the system, supporting all external interfaces and the operational user interface. The LT-3110S Control Unit is designed for indoor mounting. See the specifications in App. B - Specifications on page 58. Figure 2: LT-3110S Control Unit (front view).
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting The LT-3110S Control Unit interfaces are described in Interfaces on page 23. The LT-3110S Control Unit, front and backside view, are illustrated in Figure 2 and Figure 3. Figure 3: LT-3110S Control Unit (backside view). The LT-3110S Control Unit user interface, display and buttons, are described in User Interface (UI) on page 30.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting The Bracket Mount and Flush Mount for the LT-3110S Control Unit are illustrated in Figure 4 and Figure 5. Figure 4: Bracket Mount, Control Unit. Lars Thrane A/S Figure 5: Flush Mount, Control Unit. www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting LT-3120 Handset The LT-3120 Handset is the primary voice interface for the LT-3100S GMDSS system. The LT-3120 Handset must be connected on the front of the LT-3110S Control Unit. The connector is illustrated in Figure 2 on page 6. Figure 6: LT-3120 Handset (front view). The LT-3120 Handset is connected to the LT-3110S Control Unit via a 5-pin proprietary angle connector. The spiral cord, fixed to the LT-3120 Handset is ~ 0.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting LT-3121 Cradle The LT-3121 Cradle is used together with the LT-3120 Handset. The LT-3121 Cradle should be mounted next to the LT-3110S Control Unit, supporting the LT-3120 Handset. The LT-3121 Cradle specifications are available in App. B - Specifications on page 58. Figure 9: LT-3121 Cradle (front view).
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting LT-3130 Antenna Unit The LT-3130 Antenna Unit is designed for outdoor mounting and connected to the LT-3110S Control Unit via a coaxial cable. The LT-3130 Antenna Unit specifications are available in App. B - Specifications on page 58. The LT-3130 Antenna Unit has an N connector (female) mounted, centered at the bottom of the antenna. Figure 10: LT-3130 Antenna Unit.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting In order to avoid breaking the LT-3130 Antenna Unit N-connector (female), it is important not to use tooling when connecting and fastening the coaxial cable N-connector (male) to the antenna unit. The coaxial cable N-connector thread nut must be fastened only by using handcraft. Figure 11: Connecting coaxial cable N-connector to the LT-3130 Antenna Unit.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting WARNING: The safety distance from the LT-3130 Antenna Unit, is 0.1 m (0.3 ft), in order to comply with the regional regulations. IMPORTANT: Due to the adjacency of the Iridium and Inmarsat frequency bands, the LT-3100 Satellite Communications System may not co-operate in the proximity of active Inmarsat equipment. The LT-3130 Antenna Unit must be installed outside the radar main beam.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting The LT-3130 Antenna Unit shall me mounted minimum 1 m from MF-HF, VHF, and UHF antennas. Figure 13: LT-3130 Antenna Unit – Separation to MF-HF, VHF, and UHF antennas. NOTE: The LT-3130 Antenna Unit must be installed with a 360° clear view of the sky.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting LT-3140S Interface Unit The LT-3140S Interface Unit is designed for indoor mounting and is connected directly to the LT-3110S Control Unit via an Ethernet cable. The LT-3140S Interface Unit specifications are available in App. B Specifications on page 58. Figure 15: LT-3140S Interface Unit (without front cover). The LT-3140S Interface Unit without front cover is illustrated in Figure 30 on page 28.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting LT-3150S Alarm Panel The LT-3150S Alarm Panel is designed for indoor mounting and connected to the LT-3140S Interface Unit via a proprietary 4-wire CAN cable. The LT-3150S Alarm Panel specifications are available in App. B Specifications on page 58. Figure 16: LT-3150S Alarm Panel The LT-3150S Alarm Panel consist of the following human interface functions: DISTRESS button, DIM button, and speaker.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting The LT-3150S Alarm Panel must be flush mounted. A bracket mount is delivered together with the LT-3150S Alarm Panel. The LT-3150S Alarm Panel with the bracket mount is illustrated in Figure 17. Figure 17: LT-3150S Alarm Panel (backside view). The LT-3150S Alarm Panel can be released from the bracket mount by using a release tool as illustrated in Figure 19 and Figure 18.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting LT-3160S Printer Adapter The LT-3160S Printer Adapter is designed for indoor mounting and connected to the LT-3140S Interface Unit via a proprietary 4-wire CAN cable. The LT-3160S Printer Adapter specifications are available in App. B Specifications on page 58.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting Bracket Mount, Antenna Unit The Bracket Mount (1.5” to 2.5” tube), Antenna Unit installation options are illustrated in Figure 21 to Figure 24. Figure 22: Bracket Mount (1.5” to 2.5” tube), Antenna Unit – vertical tube mount. Figure 21: Bracket Mount (1.5” to 2.5” tube), Antenna Unit – vertical tube mount. Bracket mount installation procedure: 1. Fasten the bracket mount to a tube (max. 2.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting Figure 23: Bracket Mount (1.5” to 2.5” tube), Antenna Unit – horizontal tube mount. The Bracket Mount (1.5” to 2.5” tube), Antenna Unit can support tubes in the interval 1.5” to 2.5”. The torques are specified in Figure 17. The bracket mount, V-bolts, and nuts are all made of A4 stainless steel Figure 24: Bracket Mount (1.5” to 2.5” tube), Antenna Unit – horizontal tube mount. Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Installation and Mounting Pole Mount, Antenna Unit The Pole Mount (1.5” tube), Antenna Unit is illustrated in Figure 25 to Figure 27. Figure 25: Pole Mount (1.5” tube), Antenna Unit. Pole mount installation procedure: 1. 2. 3. 4.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Figure 26: Pole Mount (1.5” tube), Antenna Unit. NOTE: Lars Thrane A/S Installation and Mounting Figure 27: Pole Mount (1.5” tube), Antenna Unit. The Pole Mount (1.5” tube), Antenna Unit only support a 1.5” tube. The pinot screws (antenna and pole lock) torques are specified in Figure 26 and Figure 27. The pole mount is made of milled aluminum (anodized). The pinot screws are made of A4 stainless steel. www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Interfaces Interfaces LT-3110S Control Unit This section will describe all the external interfaces to the LT-3110S Control Unit, including the coaxial cable interface to the LT-3130 Antenna Unit. DC input The LT-3100S GMDSS system is designed to be used on 12 VDC and 24 VDC power buses (nominal). External DC power to the LT-3100S GMDSS system is provided by connecting the proprietary 91-102118 power cable, 3m - delivered by Lars Thrane A/S.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 NOTE: Interfaces The LT-3110S Control Unit must be powered off when inserting, changing, or removing the SIM card. The SIM card is hidden behind the rubber dust cover on the back side of the LT3110S Control Unit. Figure 28 is showing an Iridium GMDSS SIM card. The format is Mini-SIM (2FF) 25 x 15 mm. The SIM card must be removed from the full-sized card carrier by breaking the Mini-SIM out.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Interfaces Ethernet (RJ45) The LT-3110S Control Unit has an Ethernet LAN (RJ-45) interface, supporting service & maintenance or connection to the LT-3140S Interface Unit. The Ethernet interface can be used to access the built-in web server, which is further described in Web server on page 49. The LT-3110S Control Unit will automatically request and obtain an IP address when connected to a Local Area Network (LAN) with a DHCP server (e.g. a router).
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Interfaces LT-3130 Antenna Unit The LT-3110S Control Unit and the LT-3130 Antenna Unit must be connected using a coaxial cable. Both the control unit and the antenna unit has a N connector (female) mounted. This section will specify the requirements to the coaxial cable. The minimum set of requirements are specified in Table 5 and Figure 29. Cable impedance Maximum signal loss Maximum DC resistance 50 Ω 47.7 dB/100 m @ 1.5 GHz See Figure 29.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Interfaces In Figure 29 two different input voltages (12 VDC and 24 VDC) illustrate the maximum length of the coaxial cable as a function of the DC cable resistance. NOTE: The DC cable resistance that is illustrated in Figure 29 and used to calculate the maximum cable length is the sum of the DC inner conductor resistance and the DC outer conductor resistance.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Interfaces LT-3140S Interface Unit The LT-3140S Interface Unit is designed for indoor mounting and connected to the LT-3110S Control Unit via an Ethernet cable. The LT-3140S Interface Unit specifications are available in App. B - Specifications on page 58. Cable strain relief must be used for securing all cables connected to the LT-3140S Interface Unit. Figure 30: LT-3140S Interface Unit.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Interfaces NOTE: 3 x spare Ethernet interfaces are available on the LT-3140S Interface Unit to support future information protocols. It is possible to support the LT-3100S GMDSS system by connecting an external PC to one of the free Ethernet ports on the LT-3140S Interface Unit (e.g. for software updating the system or downloading a diagnostic report).
LT-3100S GMDSS User & Installation Manual Rev. 1.02 User Interface (UI) User Interface (UI) The LT-3100S GMDSS system is controlled from the LT-3110S Control Unit, which is the interface for operating and configuring the system. The control unit has a 4.3” TFT-LCD display, supporting day and night modes. The layout of the display and buttons is illustrated in Figure 31. Figure 31: Control Unit (front view) – user interface display and buttons.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 • • User Interface (UI) Navigation buttons: The navigation buttons (BACK, arrows, and ENTER) are used for navigation purposes in the menu layout. In context of user input or when making selections, the BACK button will erase input or cancel editing respectfully, the ENTER button will end input or apply selection respectfully.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 User Interface (UI) Network Status – Slot 1 The LT-3100 system has no satellite signal and is not registered on the Iridium® Network. The LT-3100 system has satellite signal = 0 and is registered on the Iridium® Network. The LT-3100 system has satellite signal = 1 and registered on the Iridium® Network. The LT-3100 system has satellite signal = 5 and registered on the Iridium® Network.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 User Interface (UI) Audio – Slot 4 The microphone on the handset is muted. Table 12: LT-3110S Control Unit - UI audio Input Mode – Slot 5 The numeric keypad can be used to enter a phone number or numeric number. The numeric keypad can be used to enter text. The first letter of a sentence will be in upper case. The numeric keypad can be used to enter text. All letters will be in lower case. The numeric keypad can be used to enter text.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 User Interface (UI) BAM Status – Slot 7 Active – unacknowledged warning Active – silenced warning Active – acknowledged warning Active – responsibility transferred warning Rectified – unacknowledged warning Active caution Table 14: LT-3110S Control Unit - UI BAM status Menu system The LT-3100S GMDSS system’s main menu is accessed by pressing the MENU button on the keypad. The user will be presented with a layout as illustrated in Figure 34.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Sub-menus GMDSS Phone Settings System User Interface (UI) Entries MSI Inbox MSI Setup RCC List RCC Messages Position Setup Distress Alert Setup SES Information System Test Contacts Messages Call History Data History Phone Usage Audio Display Date & Time Phone Setup Network Bluetooth (not for SOLAS) Tracking Security SIP Status GNSS Status Alert List System Information Power Supply Reset Options Table 15: LT-3110S Control Unit, sub-menu layout.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 User Interface (UI) System status The LT-3100S GMDSS system installation and mounting is described in the previous sections. After the LT3100S GMDSS system has been installed and properly connected, the system will automatically start-up and register on the Iridium® Network.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 User Interface (UI) Additional user information is available in the system and represented as a system text or as an icon in the status bar. Table 17 is listing the system text and describing the status of the LT-3100S GMDSS system.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system Using the system Distress Alert Initiating a Distress Alert The Distress Alert function can be activated using the DISTRESS button on the LT-3110S Control Unit or from the DISTRESS button on the LT-3150S Alarm Panel. The procedure for activating the Distress Alert function is the same for both buttons: 1. Lift the red lid marked DISTRESS 2.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system Canceling a Distress Alert To cancel a Distress Alert, press the Cancel Distress soft key. The system will then notify the preferred RCC the Distress Alert has been canceled. Maritime Safety Information (MSI) Receiving MSI The system automatically receives MSI messages and, depending on the priority of the message, will notify the user with an audible signal.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system The system automatically receives priority messages from an RCC and, depending on the priority of the message, will notify the user with an audible signal. To read received priority messages go to MENU -> GMDSS -> RCC Messages, select a message and press ENTER to see its message body. Non-priority voice call The LT-3100S GMDSS system must be properly installed, connected, and configured before trying to establish a phone call.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system a. Lift the handset out of the cradle or b. Press the off-hook button (green handset button) 3. The LT-3100S GMDSS system will now establish a connection to the dialed number Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system Off-hook mode: In off-hook mode, the user starts to place the LT-3100S GMDSS system into off-hook mode (ready tone available). The off-hook mode can be obtained in two ways: lifting the handset out of the cradle or pressing the green off-hook button, prior to typing any digits of the called number.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system The voice call connection can be described with the following states: • • • State 1: Type in number State 2: “Connecting…” State 3: “Duration: MM:SS” – (if call is successfully connected) where MM are minutes and SS are seconds. The “Connecting…” and “Duration: MM:SS” states are illustrated in Figure 38 and Figure 39.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system Position of vessel The system is configured to default use the built-in GNSS receiver (automatic mode) for determining the current position of the vessel.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system highest priority (see Table 18 on page 46). It is not possible to hide or suppress the BAM icon in the status bar. Alert list Once the user has become aware an alert has been raised, the user can navigate to the alert list (MENU -> System -> Alert List) to find further information about the alert conditions. NOTE: For quick access to the alert list, long press (≥ 1 s) the MENU button at any time.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Priority Icon State Condition Audible signal Active – unacknowledged Alert condition present. Alert not acknowledged. Yes Active – silenced Alert condition present. Alert not acknowledged, but audible signal has been silenced by the operator. No Active – acknowledged Alert condition present. Alert acknowledged by the operator. No Active – responsibility transferred Alert condition present.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Using the system Alert acknowledgement Alerts of priority warning must be acknowledged by the user. When an alert is both acknowledged and rectified it disappears from the alert list. Cautions cannot be acknowledged and thus disappear as soon as they are rectified.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 NOTE: Using the system Alerts of priority caution cannot be acknowledged and therefore cannot have their responsibility transferred. The alert text and alert description of an alert is presented on the CAM system. For some alerts, additional information must be presented in order to allow user acknowledgement of the alert.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Web server Web server The LT-3110S Control Unit has a built-in webserver, which can be accessed from the Ethernet (RJ45) interface from the back side of the control unit. A PC must be connected to the control unit, either directly by connecting an Ethernet cable between a PC and the LT-3110S Control Unit, or by connecting the LT3110S Control Unit to a Local Area Network (LAN), to where the PC is connected.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Web server Figure 43: LT-3110S Control Unit – built-in web server (Configuration). Under Configuration, the following web pages are available: • • • • • • • • • Authentication GMDSS Network Bluetooth (only available if none SOLAS vessel) Data SIP Tracking GNSS and NMEA output Reset The functionality of the Dashboard, Software update, and Diagnostic report web pages are described in further details in this version of the User & Installation Manual.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Web server Dashboard The dashboard is showing details about the main units, which forms the Satcom system: the LT-3110S Control Unit, the LT-3130 Antenna Unit, the LT-3140S Interface Unit, the LT-3150S Alarm Panel, and the LT3160S Printer Adapter. If the antenna unit is connected properly to the control unit, then the antenna unit will be visible on the web server dashboard, as illustrated in Figure 42. Otherwise only the control unit will be visible.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Web server Accessing the built-in web server To access the built-in web server of the LT-3110S Control Unit, please complete the following steps: 1. Connect the LT-3110S Control Unit directly to a PC using an Ethernet cable, or connect the LT3110S Control Unit to a Local Area Network (LAN), where a PC is connected. 2. Identify the IP address that is assigned to the LT-3110S Control Unit.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Service & Repair Service & Repair This section describes what the end-user must do in case of required service or repair. NOTE: The LT-3100S GMDSS system does not require any scheduled maintenance or service. Make sure that the product is installed, as described in this manual, before making contact to the distributor or dealer for further assistance.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes Appendixes App. A - Bridge Alert Management (BAM) Alert generating functions The LT-3100S GMDSS system contains the following functions capable of raising alerts. Name Can be deactivated GMDSS No Responsible for all GMDSS services (Distress Alert, Distress Alert Relay, MSI, priority voice, priority messaging). It is not possible to deactivate this function. Positioning Yes Responsible for monitoring automatic (GNSS) and manual position.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes List of alerts ID: 3013 Title: Doubtful pos Description: GMDSS update manual position What to do: Update the manual position as described in Position of vessel on page 44. Conditions: Raised in manual position mode if manually set position is older than 4 hours. Rectified upon update of manual position. Cleared to normal if position mode is set to automatic.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 ID: 3122 Title: Distress Rx Description: Incoming distress. Check GMDSS display What to do: Read the received Distress Alert Relay (see Maritime Safety Information (MSI) on page 39). Conditions: Raised when a Distress Alert Relay message is received. Rectified when all Distress Alert Relay messages have been read. Escalation: Repeated as a warning after 30 s.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 ID: 3123 Title: Safety Rx Description: Check new received safety message What to do: Read the received priority message (see Priority messaging on page 39). Conditions: Raised when a safety priority message is received. Rectified when all priority messages of severity safety have been read. ID: 10003 Title: Lost service Description: Missing SIM card.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. B - Specifications LT-3100S GMDSS Satellite Communications System Certification & standards Maritime CE, FCC, ISED, RCM, MED (Wheelmark), RoHS 2, Iridium® Vibration, operational IEC 60945 (sine) & proprietary Maritime Random profile Vibration, survival Proprietary Maritime Random profile Vibration, shock Proprietary Maritime profile (20 g, 11 ms) Compass Safe Distance, std. 0.85 m (2.8 ft) TBC Compass Safe Distance, steer. 0.65 m (2.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. B - Specifications (continued) LT-3140S Interface Unit Power consumption: operating mode, max Power consumption: sleep mode, max Weight Dimensions Temperature, operational IP rating, dust and water Interfaces Input voltage 7.90 W 0.08 W 0.71 kg (1.57 lbs) 227.0 x 186.0 x 40.0 mm (8.94 x 7.32 x 1.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. C - Outline Drawing: LT-3110S Control Unit Figure 45: Outline Drawing: LT-3110S Control Unit Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. D - Outline Drawing: Bracket Mount, Control Unit Figure 46: Outline Drawing: Bracket Mount, Control Unit Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. E - Outline Drawing: Flush Mount, Control Unit Figure 47: Outline Drawing: Flush Mount, Control Unit Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. F - Outline Drawing: LT-3130 Antenna Unit Figure 48: Outline Drawing: LT-3130 Antenna Unit Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. G - Outline Drawing: LT-3140S Interface Unit Figure 49: Outline Drawing: LT-3140S Interface Unit Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. H - Outline Drawing: LT-3150S Alarm Panel Figure 50: Outline Drawing: LT-3150S Alarm Panel Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. I - Outline Drawing: LT-3160S Printer Adapter Figure 51: Outline Drawing: LT-3160S Printer Adapter Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. J - Outline Drawing: Pole Mount, Antenna Unit NOTE: The Pole Mount (1.5” tube), Antenna Unit interfaces to a tube of maximum 1.5” (38.1 mm), measured outer diameter. The total weight of the Pole Mount is 0.18 kg (0.40 lbs). Figure 52: Outline Drawing: Pole Mount (1.5” tube), Antenna Unit Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. K - Outline Drawing: Bracket Mount, Antenna Unit NOTE: The Bracket Mount (1.5” to 2.5” tube), Antenna Unit interfaces to a tube of maximum 2.5” (63.5 mm), measured outer diameter. The total weight of the Bracket Mount is 0.68 kg (1.50 lbs). Figure 53: Outline Drawing: Bracket Mount (1.5” to 2.5” tube), Antenna Unit Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. L - Outline Drawing: LT-3120 Handset Figure 54: Outline Drawing: LT-3120 Handset Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. M - Outline Drawing: LT-3121 Cradle Figure 55: Outline Drawing: LT-3121 Cradle Lars Thrane A/S www.thrane.
LT-3100S GMDSS User & Installation Manual Rev. 1.02 Appendixes App. N - EU Declaration of Conformity Not available yet (pending BABT approval) Lars Thrane A/S www.thrane.
Lars Thrane A/S Skovlytoften 33 2840 Holte Denmark www.thrane.