Cut Sheet
for current information see: www.lappusa.com • www.lappcanada.com102
ÖLFLEX
®
Flexible cable for drives, motors & assemblies
Application advantage
Construction
ECOLAB
®
is a registered trademark of Ecolab, Inc.
Recommended SKINTOP
®
assumes minimal OD variance. Additional congurations are available; please see our SKINTOP
®
section.
If not otherwise specied, all values relating to the product are nominal values. Photographs are not to scale and are not true representations of the products in question.
Recommended applications
Complete the installation
SKINTOP
®
MS-SC
page 522
EPIC
®
ULTRA HB
page 404
Approvals
VFD cable
Technical data
Minimum bend radius: 7.5 x cable diameter
Temperature range:
- UL/CSA TC: -25°C to +90°C
- for stationary use: -40°C to +105°C
- for exible use: -25°C to +105°C
Nominal voltage:
- UL/CSA TC: 600V
- UL WTTC: 1000V
- UL Flexible Motor Supply: 1000V
- UL/CSA AWM: 1000V
Test voltage: 2000V
Peak voltage: 7500V
Conductor stranding:
- 16 - 6 AWG: Class 5 ne wire
- 4 AWG: Class K ne wire
Color code: b lack with white numbers,
plus green/yellow ground and
one black pair with white numbers
Approvals: UL: TC-ER per UL 1277
MTW per UL 1063
WTTC per UL 2277
AWM 20886
Attributes: UL Oil Res I/II
75°C wet; 90°C dry
-40°C cold bend; -25°C cold impact
sunlight resistant
NFPA 79
NEC: C lass 1 Division 2 per NEC Article 501
Canada: c(UL) CIC/TC FT4
CSA AWM I/II A/B 1000V FT4
Additional: MSHA P-07-KA050011-MSHA
CE & RoHS
Cable attributes page 648
OIL
OR-03
FLAME
FR-03
MOTION
FL-01
MECH.
MP-03
• LAPP Surge Guard insulation system
• UL TC-ER & c(UL) CIC TC approved
• Double-shielded for extra protection
• Contains pair for brake or temperature sensor
• Resistant to a wide range of disinfecting solutions used
in the food, beverage, chemical and related industries,
according to ECOLAB
®
PM 40-1 test procedure
VFD drive and motor connections with temperature sensors or brake
mechanisms; web presses; HVAC; on/o, slow down/speed up applications
ÖLFLEX
®
VFD with Signal is an extremely oil- and UV-resistant shielded motor power
cable for VFD drives, with an additional pair for brake or temperature sensor. It is
designed with LAPP Surge Guard insulation, which includes a semiconductive layer
made to withstand nonlinear power distortions associated with VFD drives and to
disperse increases in voltage. It is resistant to a wide range of disinfecting solutions
used in the food, beverage, chemical and related industries.
Conductors: nely stranded tinned copper
Insulation: LAPP Surge Guard insulation system
Shielding: barrier tape; triple layer foil tape (100% coverage);
tinned copper braid (85% coverage)
Jacket: specially formulated thermoplastic polymer; black
ÖLFLEX
®
VFD with Signal
Flexible VFD cable with a control pair; 600V/1000V; UL & c(UL) TC-ER approval
LAPP KABEL ÖLFLEX
®
VFD with Signal
Part
number
Number of
conductors
Nominal
outer diameter
Copper
weight
Approx.
weight
SKINTOP
®
MS-SC
SKINTOP
®
MS-M BRUSH
incl. ground in mm lbs/mft lbs/mft PG thread metric thread
16 AWG (1.5 mm²)
7416048 4 + (18 AWG) 0.519 13.2 88 180 53112240 53112676
14 AWG (2.5 mm²)
7414048 4 + (18 AWG) 0.573 14.6 118 216 53112250 53112676
7414044 4 + (14 AWG) 0.600 15.2 141 254 53112250 53112676
12 AWG (4 mm²)
7412048 4 + (18 AWG) 0.632 16.1 162 286 53112250 53112677
7412044 4 + (14 AWG) 0.662 16.8 187 326 53112250 53112677
Part
number
Number of
conductors
Nominal
outer diameter
Copper
weight
Approx.
weight
SKINTOP
®
MS-SC
SKINTOP
®
MS-M BRUSH
incl. ground in mm lbs/mft lbs/mft PG thread metric thread
10 AWG (6 mm²)
7410044 4 + (14 AWG) 0.745 18.9 260 406 53112260 53112677
8 AWG (10 mm²)
7408044 4 + (14 AWG) 0.896 22.8 375 617 53112260 53112678
6 AWG (16 mm²)
7406044 4 + (14 AWG) 1.026 26.1 472 848 53112270 53112678
4 AWG (21 mm²)
7404044 4 + (14 AWG) 1.324 33.6 643 12 51 — 53112679
( ) = shielded pair
FIRE