Cut Sheet

Table Of Contents
for current information see: www.lapptannehill.com • 800.633.6339
ÖLFLEX
®
Tray-rated cable
Unshielded construction
VNTC
®
is a registered trademark of General Cable.
If not otherwise specied, all values relating to the product are nominal values.
Photographs are not to scale and are not true representations of the products in question.
Industrial plant expansions; automotive plants; tray wiring; anywhere VNTC
®
cables are used
Recommended applications
Complete the installation
SKINTOP
®
strain relief
page 492
EPIC
®
connectors
page 284
Application advantage
Shielded construction
ÖLFLEX
®
TRAY II/TRAY II CY
Extremely oil-resistant & exible tray cable with UL & CSA; unshielded & shielded
LAPP KABEL ÖLFLEX
®
TRAY II
LAPP KABEL ÖLFLEX
®
TRAY II CY
Technical data
Minimum bend radius:
- for installation:
- < 1 AWG: 4 x cable diameter
- ≥ 1 AWG: 6 x cable diameter
- shielded: 6 x cable diameter
Temperature range:
- UL/CSA TC: -25°C to +90°C
- for stationary use: -40°C to +105°C
- for exible use: -25°C to +105°C
Nominal voltage:
- UL/CSA TC: 600V
- UL WTTC/CSA AWM: 1000V
Test voltage:
- up to 1 AWG: 2000V
- 1 AWG & larger: 4000V
Conductor stranding:
- 18 - 6 AWG: Class 5 ne wire*
- 4 - 2 AWG: Class K ne wire
- 1 AWG - 500 KCMIL: stranded wire
* 18 AWG meets only Class 5 cross section and DC resistance
Color code: b lack with white printing,
plus green/yellow ground
Approvals: UL: TC-ER per UL 1277
MTW per UL 1063
WTTC per UL 2277
submersible pump (14 - 2 AWG)
PLTC-ER per UL 13 (18 - 12 AWG)
ITC-ER per UL 2250 (18 - 12 AWG)
DP-1 per UL 1690
AWM 20886 (18 - 2 AWG)
Attributes: UL Oil Res I/II
75°C wet; 90°C dry
sunlight resistant
direct burial
NFPA 79
NEC: Class 1 Division 2 per NEC Article 501
Canada: c(UL) CIC/TC FT4 (18 - 4/0 AWG)
CSA AWM I/II A/B FT4
Additional: t orsion rated for wind market
(± 90°/m) & (± 150°/m)
(18 - 2 AWG)
CE & RoHS
MSHA: P-07-KA050016-MSHA
(shielded only)
Cable attributes page 648
OIL
OR-03
FLAME
FR-03
MOTION
WT-02
MECH.
MP-03
Oil-resistant pressure-extruded jacket improves exibility
Easier to pull than standard tray cables; lower labor costs
UL TC-ER reduces material costs; no conduit is needed
Black numbered conductors for easy identication
Improved shielding eectiveness
Conductors: nely stranded bare copper
Insulation: specially formulated PVC/nylon
Shielding: foil tape; tinned copper braid (70% coverage)
Jacket: specially formulated thermoplastic polymer; black
Conductors: nely stranded bare copper
Insulation: specially formulated PVC/nylon
Jacket: specially formulated thermoplastic polymer; black
ÖLFLEX
®
TRAY II is an industrial grade tray cable with superior oil performance
for long cable life. It has a pressure-extruded jacket and ne copper stranding
for excellent exibility, making it much easier to pull through tray. With UL
TC-ER approval, no conduit is needed so you can reduce material costs along
with saving on labor. ÖLFLEX
®
TRAY II CY is designed with foil tape and tinned
copper braid shield for improved eectiveness.
FIRE
PROTECTION
Approvals

Summary of content (2 pages)