Cut Sheet
for current information see: www.lapptannehill.com • 800.633.6339
ÖLFLEX
®
Tray-rated cable
Unshielded construction
VNTC
®
is a registered trademark of General Cable.
If not otherwise specied, all values relating to the product are nominal values.
Photographs are not to scale and are not true representations of the products in question.
Industrial plant expansions; automotive plants; tray wiring; anywhere VNTC
®
cables are used
Recommended applications
Complete the installation
SKINTOP
®
strain relief
page 492
EPIC
®
connectors
page 284
Application advantage
Shielded construction
ÖLFLEX
®
TRAY II/TRAY II CY
Extremely oil-resistant & exible tray cable with UL & CSA; unshielded & shielded
LAPP KABEL ÖLFLEX
®
TRAY II
LAPP KABEL ÖLFLEX
®
TRAY II CY
Technical data
Minimum bend radius:
- for installation:
- < 1 AWG: 4 x cable diameter
- ≥ 1 AWG: 6 x cable diameter
- shielded: 6 x cable diameter
Temperature range:
- UL/CSA TC: -25°C to +90°C
- for stationary use: -40°C to +105°C
- for exible use: -25°C to +105°C
Nominal voltage:
- UL/CSA TC: 600V
- UL WTTC/CSA AWM: 1000V
Test voltage:
- up to 1 AWG: 2000V
- 1 AWG & larger: 4000V
Conductor stranding:
- 18 - 6 AWG: Class 5 ne wire*
- 4 - 2 AWG: Class K ne wire
- 1 AWG - 500 KCMIL: stranded wire
* 18 AWG meets only Class 5 cross section and DC resistance
Color code: b lack with white printing,
plus green/yellow ground
Approvals: UL: TC-ER per UL 1277
MTW per UL 1063
WTTC per UL 2277
submersible pump (14 - 2 AWG)
PLTC-ER per UL 13 (18 - 12 AWG)
ITC-ER per UL 2250 (18 - 12 AWG)
DP-1 per UL 1690
AWM 20886 (18 - 2 AWG)
Attributes: UL Oil Res I/II
75°C wet; 90°C dry
sunlight resistant
direct burial
NFPA 79
NEC: Class 1 Division 2 per NEC Article 501
Canada: c(UL) CIC/TC FT4 (18 - 4/0 AWG)
CSA AWM I/II A/B FT4
Additional: t orsion rated for wind market
(± 90°/m) & (± 150°/m)
(18 - 2 AWG)
CE & RoHS
MSHA: P-07-KA050016-MSHA
(shielded only)
Cable attributes page 648
OIL
OR-03
FLAME
FR-03
MOTION
WT-02
MECH.
MP-03
• Oil-resistant pressure-extruded jacket improves exibility
• Easier to pull than standard tray cables; lower labor costs
• UL TC-ER reduces material costs; no conduit is needed
• Black numbered conductors for easy identication
• Improved shielding eectiveness
Conductors: nely stranded bare copper
Insulation: specially formulated PVC/nylon
Shielding: foil tape; tinned copper braid (70% coverage)
Jacket: specially formulated thermoplastic polymer; black
Conductors: nely stranded bare copper
Insulation: specially formulated PVC/nylon
Jacket: specially formulated thermoplastic polymer; black
ÖLFLEX
®
TRAY II is an industrial grade tray cable with superior oil performance
for long cable life. It has a pressure-extruded jacket and ne copper stranding
for excellent exibility, making it much easier to pull through tray. With UL
TC-ER approval, no conduit is needed so you can reduce material costs along
with saving on labor. ÖLFLEX
®
TRAY II CY is designed with foil tape and tinned
copper braid shield for improved eectiveness.
FIRE
PROTECTION
Approvals