Data Sheet

DATA SHEET
2170011
RG 11 A/U outdoor
valid from :
13.07.2010
elaborated by:
TE-K: A. Khan / H. Pfeffer
Document: DB2170011EN page 1 of 1
Nr.: 0019/0894
Application
Coaxial cable for receiver installations in radio communication, video- and computer systems as well as the entire
field of commercial radio-frequency technology and electronics. The low attenuation of this 75 Ohms coaxial
cable allows high range transmissions. Electrical properties of RG 11 A/U accord. to MIL-C 17 F. Cable design
accord. to MIL-C 17 F with outer sheath additional. The outer sheath can easily stripped off from the inner
sheath.
The cable is intended for limited flexible use and for static laying inside and outside as well as for underground
burial.
Design
Inner conductor stranded tinned copper wires, 0.9 mm
2
(7 x 0.4), appr. 1.2 mm
Insulation PE (polyethylene) 7.3 mm
Outer conductor bare copper braid, coverage nom. 92 %
inner sheath PVC, black, UV resistant, flame retardant, 10.3 ± 0.18 mm
Outer sheath PVC, black, UV resistant, flame retardant, 12.1 ± 0.2 mm
Electrical properties at 20°C
DC resistance inner conductor
max./km
21.5
Insulation resistance
min. Gxkm
5
Capacitance at 1 kHz nom. nF/km
67
Nominal velocity of propagation %
66
Impedance
75 ± 3
Acc. to M 17/6
Attenuation at 1 MHz dB/100m
nom. 0.7
5 MHz dB/100m
nom. 1.6
10 MHz dB/ 100m
nom. 2.2
20 MHz dB/100m
nom. 3.2
50 MHz dB/100m
nom. 5.0
100 MHz dB /100m
nom. 7.5
200 MHz dB/100m
nom. 11
400 MHz dB/100m
nom. 16 max. 17
1 GHz dB/100m
nom. 30 max. 30.84
2 GHz dB/100m
nom. 43
HF voltage, peak value (not for power purposes)
max. kV
3.5
Working voltage
(nominal voltage)
50 Hz U
eff
kV
5
Test voltage U
eff
kV
10
Mechanical and thermal properties
Weight approx. kg/km
170
Minimum bending radius fixed installation mm
65
repeated bendings mm
175
Permissible temperatur range fixed installation °C
- 40 bis + 80
moved °C
- 10 bis + 80
Fire load kWh/m
0.88
Flame propagation flame retardant to IEC 60332-1-2
RoHS directive This cable confirms to RoHS directive (2002/95/EG)