Data Sheet

DATA SHEET
2170008
RG 62 A/U
valid from :
12. 06. 2008
elaborated by:
TE-K: A. Khan / H. Pfeffer
Document: DB2170008EN page 1 of 1
Nr.: 0019/0894
Application
Coaxial cable for EDP- and computer systems as well as the entire field of commercial radio-frequency
technology and electronics. Cable design and electrical properties of RG 62 A/U according to MIL-C 17 F.
Designation according to MIL-C 17 F : M 17/30 – RG 62.
The cable is intended for static laying in dry and damp interiors and outdoor.
Design
Inner conductor solid bare copper-clad steel wire, 0.64 ± 0.025 mm
Insulation polyethylene air space, (helix of PE-thread with a PE tube over it).
3.71 ± 0.13 mm
Outer conductor bare copper braid, coverage nom. 96 %
Sheath PVC, black, UV resistant, flame retardant,
outer diameter approx. 6.15 ± 0.18 mm
Electrical properties at 20°C
DC resistance inner conductor
max./km
144
Insulation resistance
min. Gxkm
10
Capacitance at 1 kHz nom. nF/km
42
Nominal velocity of propagation %
83
Impedance
93 ± 5
Acc. to M 17/30
Attenuation at 1 MHz dB/100m
nom. 1.0
5 MHz dB/100m
nom. 2.3
10 MHz dB/100m
nom. 3.0
20 MHz dB/100m
nom. 3.9
50 MHz dB/100m
nom. 6.1
100 MHz dB/100m
nom. 9
200 MHz dB/100m
nom. 13
400 MHz dB/100m
nom. 19 max. 26.24
800 MHz dB/100m
nom. 30
1 GHz dB/100m
nom. 35 max. 42.65
2 GHz dB/100m
nom. 49
HF voltage, peak value (not for power purposes)
max.kV
0.75
Working voltage (nominal voltage)
50 Hz U
eff
kV
0.8
Test voltage U
eff
kV
2
Mechanical and thermal properties
Weight approx. kg/km
57
Minimum bending radius fixed installation mm
30
repeated bendings mm
120
Permissible temperature range fixed installation °C
- 40 bis + 80
moved °C
- 10 bis + 80
Fire load kWh/m
0.14
Flame propagation flame retardant to IEC 60332-1-2
RoHS directive This cable confirms to RoHS directive (2002/95/EG)

Summary of content (1 pages)