Application
ÖLFLEX
ROBUST 200 cables are power cables for flexible use and fixed installation for a robust mechanical use. They are
for use in dry, damp and wet rooms. Under following to the indicate temperature range is an use outside possible. At room
temperature they are increased resistant against acids, caustics solutions and certain oils, greases, waxes of vegetable,
animal, mineral and/or synthetic basis. All materials used for these cable are halogen free.
Application range
ÖLFLEX
ROBUST 200 cables are used as flexible power cable in machine tool building, in medical technology, in laundries,
in car washing equipment, in chemical industry, in composting plants and in sewage works. They are for use in the food and
beverage industry, especially for production and processing equipment of milk and meat products.
Design
Design based on
EN 50525-2-51 resp. VDE 0285-525-2-51 / HD 21.13 S1 resp. 0281-13
Conductor fine wire strands of bare copper, acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation modified PP-compound
Core identification up to 5 cores: acc. to VDE 0293-308
from 6 cores: black with white numbers
with or without GN/YE ground conductor acc. to DIN EN 50334 resp. VDE 0293-334
Outer sheath special TPE--compound
colour: black, similar RAL 9005
Electrical properties
Nominal voltage U
0
/ U 450 / 750 V
Test voltage core / core 4000 V AC
Mechanical and thermal properties
Min. bending radius occasional flexing: 10 x outer diameter
fixed installation: 4 x outer diameter
Temperature range occasional flexing: -40 °C up to +80 °C max. conductor temp.
fixed installation: -50 °C up to +80 °C max. conductor temp.
Oil resistance TM5 acc. to EN 50363-4-1 resp. VDE 0207-363-4-1
UV-resistance acc. to EN ISO 4892-2-2006, method A (change of colour allowed),
acc. to VDE 0276-605 / HD 605 S2
Ozone resistance acc. to EN 50396 resp. VDE 0473-396, method B
Tests acc. to IEC 60811 resp. VDE 0473, VDE 0472, EN 50395, EN 50396
EC-Directives This cable is conform to the EC-Directives 2006/95/EC (Low Voltage Directive)
and 2011/65/EU (RoHS, Restriction of the use of certain hazardous substances).