PRELIMINARY DRAFT PremierWave XC HSPA+ User Guide Part Number 900-678-R Revision A May 2013 PRELIMINARY DRAFT
PRELIMINARY DRAFT Copyright & Trademark © 2013 Lantronix, Inc. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix. Lantronix® registered trademark of Lantronix, Inc. DeviceInstaller and PremierWave© are trademark of Lantronix, Inc. Windows® and Internet Explorer® are registered trademarks of Microsoft Corporation. Mozilla® and Firefox® are registered trademarks of the Mozilla Foundation.
PRELIMINARY DRAFT Table of Contents List of Figures _____________________________________________________________ 9 List of Tables _____________________________________________________________ 10 1: Using This Guide 12 Purpose and Audience _____________________________________________________ 12 Summary of Chapters ______________________________________________________ 12 Additional Documentation ___________________________________________________ 13 2: Introduction 14 Key Features ___________________
PRELIMINARY DRAFT 6: Network Settings 32 Network 1 (eth0) Interface Settings ____________________________________________ 32 To Configure Network Interface Settings ____________________________________ 33 To View Network Interface Status _________________________________________ 33 Network 1 (Link) Settings ___________________________________________________ 34 To Configure Network Link Settings ________________________________________ 34 Network 1 (Failover) ______________________________________________
PRELIMINARY DRAFT To Configure Tunnel Accept Mode Settings __________________________________ 51 Connect Mode ________________________________________________________ 51 To Configure Tunnel Connect Mode Settings ________________________________ 52 Disconnect Mode ______________________________________________________ 52 To Configure Tunnel Disconnect Mode Settings ______________________________ 53 Modem Emulation ______________________________________________________ 53 To Configure Tunnel Modem Emulation S
PRELIMINARY DRAFT SSH Client Users ______________________________________________________ 68 To Configure SSH Settings ______________________________________________ 69 SSL Settings _____________________________________________________________ 69 Certificate and Key Generation ___________________________________________ 69 To Create a New Credential ______________________________________________ 70 Certificate Upload Settings _______________________________________________71 To Configure an Existing SSL Cre
PRELIMINARY DRAFT To View Thread Information ______________________________________________ 81 Clock ___________________________________________________________________ 81 To Specify Clock Setting Method __________________________________________ 82 System Settings __________________________________________________________ 82 To Reboot or Restore Factory Defaults _____________________________________ 82 Discovery and Query Port ___________________________________________________ 83 To Configure Discovery __
PRELIMINARY DRAFT 17: Branding the PremierWave XC HSPA+ 96 Web Manager Customization ________________________________________________ 96 Short and Long Name Customization __________________________________________ 97 To Customize Short or Long Names _______________________________________ 97 Appendix A: Technical Specifications 98 Network _________________________________________________________________ 98 Cellular ______________________________________________________________ 98 Ethernet _____________
PRELIMINARY DRAFT List of Figures Figure 2-1 PremierWave XC HSPA+Product Label ______________________________________ 17 Figure 3-1 PremierWave XC HSPA+ Top/Front View_____________________________________ 19 Figure 3-2 PremierWave Male DB9 DTE Serial Ports ____________________________________ 20 Figure 3-3 PremierWave Pinout Configuration for RS-232 _________________________________ 20 Figure 3-4 PremierWave Pinout Configuration for Full Duplex RS-422/485 (4-wire ______________ 20 Figure 3-5 PremierWave Pin
PRELIMINARY DRAFT List of Tables Table 3-6 PremierWave LEDs and Descriptions ________________________________________ 21 Table 3-7 Cellular Signal Strength Indicator ___________________________________________ 21 Table 3-8 Diagnostic LED Indications ________________________________________________ 22 Table 3-9 PremierWave Bottom/Back Panel View _______________________________________ 23 Table 3-10 PremierWave XC HSPA+ Connections (Side) _________________________________ 23 Table 6-1 Network Interface Settin
PRELIMINARY DRAFT Table 12-1 SSH Server Host Keys ___________________________________________________ 66 Table 12-2 SSH Client Known Hosts _________________________________________________ 67 Table 12-3 SSH Server Authorized Users _____________________________________________ 68 Table 12-4 SSH Client Users _______________________________________________________ 68 Table 12-5 Certificate and Key Generation Settings _____________________________________ 70 Table 12-6 Upload Certificate Settings ______________
PRELIMINARY DRAFT 1: Using This Guide Purpose and Audience This guide provides the information needed to configure, use, and update the PremierWave XC HSPA+. It is intended for software developers and system integrators who are installing this product into their designs. Summary of Chapters The remaining chapters in this guide include: Chapter Description 2: Introduction Main features of the product and the protocols it supports. Includes technical specifications.
PRELIMINARY DRAFT Caution: 1: Using This Guide To avoid electric shock and for the device to work properly, do not allow cleaning solution to get inside the device, specifically the interface port connectors, power connector, or power cord. Do not immerse the device in any liquid. Additional Documentation Visit the Lantronix Web site at www.lantronix.com/support/documentation for the latest documentation and the following additional documentation.
PRELIMINARY DRAFT 2: Introduction PremierWave XC HSPA+ is a multi-port device server offering ethernet and cellular connectivity for remote access and easy management of machines or equipment over the network and across the internet. Key Features Power Supply: 9-30VDC input voltage through locking barrel connector. 12V wall cube power supply included with unit. Controller: 32-bit ARM9 microprocessor running at 400 megahertz (Mhz) with 16 Kilobytes (KB) Data Cache and 16 KB of Instruction Cache.
PRELIMINARY DRAFT 2: Introduction ARP, HTTP, HTTPS, SMTP AUTH, SNMP v1/v2c/v3, Modbus TCP, UDP/IP, TCP/IP, SSH, SSL, TLS, RSS, UPnP, ICMP, BOOTP, DHCP, Auto IP, Telnet, SNTP, FTP, FTPS, DNS, TFTP, XML and Syslog for network communications and management. TFTP for uploading/downloading files. FTP and HTTP/HTTPS web server for firmware upgrades and uploading/downloading files.
PRELIMINARY DRAFT 2: Introduction Addresses and Port Numbers Hardware Address The hardware address is also referred to as the Ethernet address, physical address, or MAC address. Sample hardware address: 00-80-A3-14-1B-18 00:80:A3:14:1B:18 IP Address Every device connected to an IP network must have a unique IP address. This address references the specific unit.
PRELIMINARY DRAFT 2: Introduction Figure 2-1 PremierWave XC HSPA+Product Label Data Code Part Number Revision Serial Number IMEI Text Country of Origin PremierWave XC HSPA+ User Guide PRELIMINARY DRAFT 17
PRELIMINARY DRAFT 3: Installation of PremierWave XC HSPA+ This chapter describes how to install the PremierWave XC HSPA+ device server.
PRELIMINARY DRAFT 3: Installation of PremierWave XC HSPA+ Figure 3-1 PremierWave XC HSPA+ Top/Front View Signal Strength LEDs Diagnostic LED The PremierWave has two male DB9 serial ports that support RS-232/422/485. Figure 3-2 shows the front view of the device. The default serial port settings are 9600 baud, 8 bits, no parity, 1 stop bit, no flow control.
PRELIMINARY DRAFT 3: Installation of PremierWave XC HSPA+ Figure 3-2 PremierWave Male DB9 DTE Serial Ports Serial 1 Serial 2 Reset Button USB Port Figure 3-3 PremierWave Pinout Configuration for RS-232 Figure 3-4 PremierWave Pinout Configuration for Full Duplex RS-422/485 (4-wire Figure 3-5 PremierWave Pinout Configuration for Half Duplex RS-422/485 (2-wire) PremierWave XC HSPA+ User Guide PRELIMINARY DRAFT 20
PRELIMINARY DRAFT 3: Installation of PremierWave XC HSPA+ Ethernet LEDs The Ethernet Port has two LEDs that indicate the status of the connection as follows: Left LED Green ON 100Mbps Link Green Blink 100Mbps Activity Amber ON 10Mbps Link Amber Blink 10Mbps Activity Right LED Green ON Full Duplex OFF Half Duplex The Ethernet port can connect to an Ethernet (10 Mbps) or Fast Ethernet (100 Mbps) network.
PRELIMINARY DRAFT 3: Installation of PremierWave XC HSPA+ Table 3-8 Diagnostic LED Indications Fault Conditions Blink Pattern No Ethernet link when eth0 is enabled Long, long, short, short, 2 seconds off, continuous No cellular link (no BSSID detected) when wlan0 is enabled Long, long, long, short, short, 2 seconds off, continuous No IP obtained from cellular when wlan0 is enabled and the bridge mode is disabled.
PRELIMINARY DRAFT 3: Installation of PremierWave XC HSPA+ Back Panel On the PremierWave is a Power 1 Plug and RJ-45 Ethernet port as shown in Table 3-9. Table 3-9 PremierWave Bottom/Back Panel View Relay IN2 Relay Antenna Ethernet (RX Diversity) IN1 CM2 CM1 Terminal Block Barrel Antenna Power (6-pin) Plug Power Table 3-10 PremierWave XC HSPA+ Connections (Side) Connector Description Relay Output Outputs Support 1A 24V Inputs Inputs accept voltage 0 to 30 VDC.
PRELIMINARY DRAFT 3: Installation of PremierWave XC HSPA+ Perform the following steps to install your device: 1. With the power unplugged, insert your SIM card. 2. Connect an RJ-45 Ethernet cable between the unit and your Ethernet network. 3. Connect the antennas to the SMA connectors on the back. Do note that the safe distance due to RF exposure from antenna is 20 cm. Note: Antennas must be installed prior to powering on the unit. Do not remove or connect the antennas while the unit power is on. 4.
PRELIMINARY DRAFT 4: Using DeviceInstaller This chapter covers the steps for locating a PremierWave XC HSPA+ unit and viewing its properties and device details. DeviceInstaller is a free utility program provided by Lantronix that discovers, configures, upgrades and manages Lantronix Device Servers. Notes: For instructions on using DeviceInstaller to configure the IP address and related settings or for more advanced features, see the DeviceInstaller Online Help.
PRELIMINARY DRAFT 4: Using DeviceInstaller Current Settings Description Group Configurable field. Enter a group to categorize the . Double-click the field, type in the value, and press Enter to complete. This group name is local to this PC and is not visible on other PCs or laptops using DeviceInstaller. Comments Configurable field. Enter comments for the . Double-click the field, type in the value, and press Enter to complete.
PRELIMINARY DRAFT 5: Configuration Using Web Manager This chapter describes how to configure PremierWave using Web Manager, the Lantronix browser-based configuration tool. The unit’s configuration is stored in nonvolatile memory and is retained without power. All changes take effect immediately, unless otherwise noted.
PRELIMINARY DRAFT 5: Configuration Using Web Manager Device Status Page The Device Status page is the first to appear after you log into Web Manager. The Device Status page also appears when you click Status in Web Manager. Figure 5-1 PremierWave XC HSPA+ Home Pages Note: The Logout button is available on any web page. Logging out of the web page forces re-authentication the next time the web page is accessed.
PRELIMINARY DRAFT 5: Configuration Using Web Manager Web Manager Components The layout of a typical Web Manager page is below.
PRELIMINARY DRAFT 5: Configuration Using Web Manager Web Manager pages have these sections: The menu bar appears at the left side of the page. The menu bar lists the names of the pages available. To bring up a page, click it in the menu bar. Links near the top of many pages, such as the one in the example above, enable you to link to additional pages. On some pages, you must also select the item you are configuring, such as a tunnel.
PRELIMINARY DRAFT 5: Configuration Using Web Manager Web Manager Page (continued) Description See Page Discovery Allows you to view and modify the configuration and statistics for device discovery. 83 DNS Shows the current configuration of the DNS subsystem and the DNS cache. 59 Email Shows email statistics and lets you clear the email log, configure email settings, and send an email.
PRELIMINARY DRAFT 6: Network Settings The Network Settings show the status of the Ethernet interface/link and let you configure the settings on the device. Interface settings are related to the configuration of the IP and related protocols. Link settings are related to the physical link connection, which carries the IP traffic. The PremierWave contains one network interface. The Ethernet interface is also called interface 1 or eth0. Notes: Some settings require a reboot to take effect.
PRELIMINARY DRAFT Network Interface Settings (continued) Description Default Gateway Enter the IP address of the router for this network. 6: Network Settings Note: This setting will be used if Static IP is active (both DHCP and BOOTP are Disabled). Hostname Enter the hostname for the interface. It must begin with a letter or number, continue with a sequence of letters, numbers, or hyphens, and end with a letter or number.
PRELIMINARY DRAFT 6: Network Settings To view Ethernet (eth0) Status, click Network on the menu and select Network 1 -> Interface -> Status. Network 1 (Link) Settings Physical link parameters can be configured for an Ethernet (eth0) Network Interface (see Table 6-2). Table 6-2 Network 1 (eth0) Link Settings Network 1 Ethernet (eth0) Link Settings Description Speed Select the Ethernet link speed.
PRELIMINARY DRAFT 6: Network Settings Network 1 (Failover) PremierWave XC HSPA+ provides basic Ethernet to Cellular failover, in the form of a "dead remote host reachability" mechanism (essentially a ping against a known host). If the remote host is determined to be not reachable, the device will failover to the cellular interface. If the remote host is determined to be reachable, the device will failback to the Ethernet interface.
PRELIMINARY DRAFT 6: Network Settings Network 2 (Cellular Interface) Settings Description Connection Mode The Always On connection mode keeps the device always connected to the cellular network. The On Demand connection mode leaves the link quiescent until an application attempts to make use of the cellular network connection. Be aware that in this mode, the first attempt to initiate a connection from the device server may fail, since a new IP address may need to be negotiated.
PRELIMINARY DRAFT 6: Network Settings To Configure Link Settings Using Web Manager To modify network 2 cellular interface information, click Network on the menu and select Network 2 > Link > Configuration. Using the CLI To enter the link command level: enable -> if 2 -> link Using XML Include in your file: Gateway PremierWave XC HSPA+ can be configured as a cellular gateway with DHCP server functionality.
PRELIMINARY DRAFT 6: Network Settings To Configure Gateway WAN Settings Using Web Manager To modify gateway WAN information, click Gateway on the menu and select Configuration > WAN.
PRELIMINARY DRAFT 6: Network Settings Using the CLI To enter the gateway command level: enable -> config -> gateway -> port forwarding rule Using XML Include in your file: Static Routes Allows the user to add routes to the device routing table. Static Route Settings Description Enabled Enables the static route Delete Deletes the static route Name User friendly name for the route.
PRELIMINARY DRAFT 6: Network Settings DHCP Server Allows the user to configure the device as a DHCP server. Table 6-7 DHCP Settings DHCP Settings Description State Enable or Disable the DHCP server Enabled: DHCP server is enabled Disabled: DHCP server is disabled. Start IP Address Start IP Address of address pool End IP Address End IP Address of address pool Lease time Duration for which lease is initially assigned. Clients must renew after this duration.
PRELIMINARY DRAFT 7: Cellular The Cellular page displays the configuration and status for the Cellular module. Cellular Settings Description PIN Lock Enable to prevent unauthorized use of the SIM card. PIN Enter PIN combination to enable PIN Lock. Caution: If you enter the PIN incorrectly 3 times, the SIM card will lock, and you will need a PIN Unblocking Key (PUK) to unlock your SIM card. PUK is required to unlock SIM cards that have become locked following 3 successive incorrect PIN entries.
PRELIMINARY DRAFT 8: Action Settings Actions can be configured for alarms and reports available in the PremierWave. Alarms and Reports PremierWave XC HSPA+ updates the action settings page to display and configure the alarms. The following alarm and report acations are available in PremierWave XC HSPA+: Eth0 Link State Change Wwan0 Link State Change Digital Input 1 State Change Digital Input 2 State Change One or more types of “action” can be configured and triggered when an event occurs.
PRELIMINARY DRAFT 8: Action Settings Action Settings Description HTTP Post Use HTTP Post post to configured HTTP server. The URL appears behind the HTTP server IP address or hostname. E.g. http://some_http_server/some_url The IP Address or hostname is the HTTP server to connect to. Port number is the port which HTTP server is listening on. Use Protocol to connect to HTTP server. HTTPS is a SSL encrypted communication channel and SSL Trusted Authorities must be setup withHTTP server SSL certificate.
PRELIMINARY DRAFT 8: Action Settings Digital Input Table 8-2 contain additional configuration options for Digital Input 1 and Digital Input 2 settings: Table 8-2 Digital Input Settings Digital Input Settings Description Title Fill in Title to customize how the digital input status will appear in the CLI, Web Manager, and XML status. Leave Title blank for the default title of "Digital Input N", where N is the digital input number. Normal State Select Normal State to "Low" or "High".
PRELIMINARY DRAFT 9: Line and Tunnel Settings The PremierWavehas two tunnels through which you may view statistics or configure the Accept Mode. The Modbus configuration page allows configuration of Modbus servers listening on the TCP ports. The PremierWave contains two lines . All lines use standard RS232/RS485 serial ports.
PRELIMINARY DRAFT Line Settings (continued) 9: Line and Tunnel Settings Description Data Bits Set the number of data bits for the Line. The default is 8. Stop Bits Set the number of stop bits for the Line. The default is 1. Flow Control Set the flow control for the Line. The default is None. Xon Char Set Xon Char to be used when Flow Control is set to Software. Prefix decimal with \ or prefix hexadecimal with 0x or prefix a single control character .
PRELIMINARY DRAFT 9: Line and Tunnel Settings Using Web Manager To configure a specific line, click Line in the menu and select Line 1 -> Configuration (Table 9-1). To configure a specific line in Command Mode, click Line in the menu and select Line 1 -> Command Mode (Table 9-2).
PRELIMINARY DRAFT 9: Line and Tunnel Settings Table 9-3 Tunnel Serial Settings Tunnel Serial Settings Description Line Settings Line Settings information here is display only. Go to the section, To Configure Line Settings to modify these settings. Protocol Protocol information here is display only. Go to the section, To Configure Line Settings to modify these settings. DTR Select the conditions in which the Data Terminal Ready (DTR) control signal on the serial line are asserted.
PRELIMINARY DRAFT Tunnel Packing Mode Settings (continued) 9: Line and Tunnel Settings Description Timeout Set the timeout value, in milliseconds, after the first character is received on the serial line, before data is sent on the network. Valid range is 1 to 30000 milliseconds. Default is 1000. Send Character Enter Control Characters in any of the following forms: J 0xA (hexadecimal) \10 (decimal) If used, the Send Character is a single printable character or a control character tha
PRELIMINARY DRAFT Tunnel Accept Mode Settings (continued) 9: Line and Tunnel Settings Description Local Port Set the port number for use as the network local port. The default local port number: Protocol Tunnel 1 : 10001 Tunnel 2 : 10002 Select the protocol type for use with Accept Mode: SSH SSL TCP (default protocol) TCP AES Telnet Credentials Specifies the name of the set of RSA and/or DSA certificates and keys to be used for an SSL connection.
PRELIMINARY DRAFT 9: Line and Tunnel Settings To Configure Tunnel Accept Mode Settings Using Web Manager To configure the Accept Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Accept Mode.
PRELIMINARY DRAFT Tunnel Connect Mode Settings (continued) 9: Line and Tunnel Settings Description Host 1 Click on the displayed information to expand it for editing. If is displayed, clicking it will allow you to configure a new host. At least one Host is required to enable Connect Mode as this information is necessary to connect to that host. Reconnect Timer Set the value of the reconnect timeout (in milliseconds) for outgoing connections established by the device.
PRELIMINARY DRAFT 9: Line and Tunnel Settings Table 9-7 Tunnel Disconnect Mode Settings Tunnel Disconnect Mode Settings Description Stop Character Enter the Stop Character which when received on the Serial Line, disconnects the tunnel. The Stop Character may be designated as a single printable character or as a control character. Control characters may be input in any of the following forms: J or 0xA(hexadercimal) or \10 (decimal).
PRELIMINARY DRAFT Tunnel Modem Emulation Settings (continued) Echo Commands Description Set whether characters read on the Serial Line will be echoed, while the Line is in Modem Command Mode. Choices are: Verbose Response Enabled Disabled (default) Select a representation for the Modem Response Codes sent out on the Serial Line. Choices are: Error Unknown Commands Enabled Disabled (default) Set whether Modem Response Codes are sent out on the Serial Line.
PRELIMINARY DRAFT 9: Line and Tunnel Settings Relay Output Note: When relay is energized/turned on, the relay is closed connecting both relay ports on the IO connector through the relay. When the relay is turned off, the signal path is open, disconnecting the relay ports on the IO connector. Table 9-9 Relay Output Settings Input Settings Description State Select On or Off whether to display the configuration and status for the Relays.
PRELIMINARY DRAFT 10: Terminal and Host Settings Predefined connections are available via telnet, ssh, or a serial port. A user can choose one of the presented options and the device automatically makes the predefined connection. Either the Telnet, SSH, or serial port connection can present the CLI or the Login Connect Menu. By default, the CLI is presented when the device is accessed.
PRELIMINARY DRAFT 10: Terminal and Host Settings To Configure the Terminal Network Connection Using Web Manager To configure the Terminal on Network, click Terminal on the menu and select Network -> Configuration. To configure the Terminal on Network, click Line 1 on the menu and select Network -> Configuration. To configure the Terminal on Network, click Line 2 on the menu and select Network -> Configuration.
PRELIMINARY DRAFT 10: Terminal and Host Settings Host Configuration Table 10-2 Host Configuration Host Settings Description Name Enter a name for the host. This name appears on the Login Connect Menu. To leave a host out of the menu, leave this field blank. Protocol Select the protocol to use to connect to the host. Choices are: Telnet SSH Note: SSH keys must be loaded or created on the SSH page for the SSH protocol to work. SSH Username Appears if you selected SSH as the protocol.
PRELIMINARY DRAFT 11: Services Settings DNS Settings This section describes the active run-time settings for the domain name system (DNS) protocol. The primary and secondary DNS addresses come from the active interface. The static addresses from the Network Interface configuration settings may be overridden by DHCP. Note: The blue text in the XML command strings of this chapter are to be replaced with a user-specified name.
PRELIMINARY DRAFT 11: Services Settings To Configure FTP Settings Using Web Manager To configure FTP, click FTP in the menu. Using the CLI To enter the FTP command level: enable -> config -> ftp Using XML Include in your file: Syslog Settings The Syslog information shows the current configuration and statistics of the syslog. Here you can configure the syslog host and the severity of the events to log.
PRELIMINARY DRAFT 11: Services Settings Using XML Include in your file: HTTP Settings Hypertext Transfer Protocol (HTTP) is the transport protocol for communicating hypertext documents on the Internet. HTTP defines how messages are formatted and transmitted. It also defines the actions web servers and browsers should take in response to different commands. HTTP Authentication enables the requirement of usernames and passwords for access to the device.
PRELIMINARY DRAFT 11: Services Settings HTTP Settings (continued) Description Log Format Set the log format string for the HTTP server.
PRELIMINARY DRAFT 11: Services Settings To Configure HTTP Authentication Using Web Manager To configure HTTP Authentication, click HTTP in the menu and select Authentication. Using the CLI To enter the HTTP command level: enable -> config -> http Using XML Include in your file: RSS Settings Really Simple Syndication (RSS) (sometimes referred to as Rich Site Summary) is a method of feeding online content to Web users.
PRELIMINARY DRAFT 11: Services Settings SNMP Settings Simple Network management Protocol (SNMP) settings may be viewed and configured in this section. Table 11-7 SNMP Settings RSS Settings Description System Location Specify a system location for the SNMP setting. Primary Destination Specify SNMP trap primary destination. Secondary Destination Specify SNMP trap secondary destination. Community Specify SNMP trap community.
PRELIMINARY DRAFT 11: Services Settings Outbound SMS Table 11-9 Outbound SMS Settings Outbound SMS Settings Description Message Center Default Displays the Message Center number as configured in the SIM. Number Message Center Override Number Enter a number to override the existing Message Center number. Band Select a band from the drop-down menu: GSM only GPRS only GSM preferred GPRS preferred. Number Enter the Recipient Number.
PRELIMINARY DRAFT 12: Security Settings The PremierWave XC HSPA+ device supports Secure Shell (SSH) and Secure Sockets Layer (SSL). SSH is a network protocol for securely accessing a remote device. SSH provides a secure, encrypted communication channel between two hosts over a network. It provides authentication and message integrity services. Secure Sockets Layer (SSL) is a protocol that manages data transmission security over the Internet.
PRELIMINARY DRAFT 12: Security Settings RSS Settings (continued) Description Public Key Enter the path and name of the existing public key you want to upload. In WebManager, you can also browse to the public key to be uploaded. Key Type Select a key type to use for the new key: Bit Size RSA DSA Select a bit length for the new key: 512 768 1024 Note: SSH Keys from other programs may be converted to the required PremierWave format. Use Open SSH to perform the conversion.
PRELIMINARY DRAFT 12: Security Settings Table 12-3 SSH Server Authorized Users RSS Settings Description Username Enter a new username or edit an existing one. Password Enter a new password or edit an existing one. Public RSA Key Enter the path and name of the existing public RSA key you want to use with this user. In WebManager, you can also browse to the public RSA key to be uploaded. If authentication is successful with the key, no password is required.
PRELIMINARY DRAFT RSS Settings (continued) Bit Size 12: Security Settings Description Select the bit length of the new key: 512 768 1024 Using a larger Bit Size takes more time to generate the key. Approximate times are: 1 second for a 512 bit RSA key 1 second for a 768 bit RSA key 1 second for a 1024 bit RSA key 2 seconds for a 512 bit DSA key 2 seconds for a 768 bit DSA key 20 seconds for a 1024 bit DSA key Note: Some SSH clients require RSA host keys to be at least 1024 bits long.
PRELIMINARY DRAFT 12: Security Settings Table 12-5 Certificate and Key Generation Settings Certificate Generation Settings Description Country (2 Letter Code) Enter the 2-letter country code to be assigned to the new self-signed certificate. Examples: US for United States and CA for Canada State/Province Enter the state or province to be assigned to the new self-signed certificate. Locality (City) Enter the city or locality to be assigned to the new self-signed certificate.
PRELIMINARY DRAFT 12: Security Settings Certificate Upload Settings SSL certificates identify the PremierWave to peers. Certificate and key pairs can be uploaded to the PremierWave through either the CLI or XML import mechanisms. Certificates can be identified on the PremierWave by a name provided at upload time. Table 12-6 Upload Certificate Settings Upload Certificate Settings Description New Certificate SSL certificate to be uploaded. RSA or DSA certificates are allowed.
PRELIMINARY DRAFT 12: Security Settings Trusted Authorities One or more authority certificates are needed to verify a peer's identity. These certificates do not require a private key. Table 12-7 Trusted Authority Settings Trusted Authorities Settings Description Authority SSL authority certificate. RSA or DSA certificates are allowed. The format of the authority certificate can be PEM or PKCS7. PEM files must start with “-----BEGIN CERTIFICATE-----” and end with “----END CERTIFICATE-----”.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings Filesystem Settings Use the file system to list, view, add, remove, and transfer files. The PremierWave uses a flash file system to store files. File Display It is possible to view the list of existing files, and to view their contents in the ASCII or hexadecimal formats. Table 13-1 File Display Settings File Display Commands Description ls Displays a list of files on the PremierWave, and their respective sizes.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings File Modification The PremierWave allows for the creation and removal of files on its filesystem. Table 13-2 File Modification Settings File Modification Commands Description rm Removes the specified file from the file system. touch Creates the specified file as an empty file. cp Creates a copy of a file. mkdir Creates a directory on the file system. rmdir Removes a directory from the file system.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings To Transfer or Modify Filesystem Files Using Web Manager To create a new file or directory, upload an existing file, copy or move a file, click Filesystem in the menu and select Browse. Using the CLI To enter the Filesystem command level: enable -> filesystem Using XML Not applicable. Protocol Stack Settings There are various low level network stack specific items that are available for configuration.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings ICMP Settings Table 13-5 ICMP Network Stack Settings Protocol Stack ICMP Settings Description State The State selection is used to turn on/off processing of ICMP messages. This includes both incoming and outgoing messages. Choose Enabled or Disabled. To Configure ICMP Network Stack Settings Using Web Manager To configure ICMP protocol settings, click Protocol Stack in the menu and select ICMP.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings SMTP Settings Table 13-7 SMTP Network Stack Settings Protocol Stack SMTP Description Settings From Address Enter the From Address here. This is an email address and is required. If you wish to direct oubtound email messages through a mail server, put your client email address here. Server Address Enter the Server Address to direct outbound email messages through a mail server. Server Port Enter the SMTP server port number.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings Diagnostics The PremierWave has several tools for diagnostics and statistics. Various options allow for the configuration or viewing of IP socket information, ping, traceroute, memory, and processes. Hardware To View Hardware Information Using Web Manager To view hardware information, click Diagnostics in the menu and select Hardware.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings To Ping a Remote Host Using Web Manager To ping a Remote Host, click Diagnostics in the menu and select Ping. Using the CLI To enter the command level: enable, ping Using XML Not applicable. Traceroute Here you can trace a packet from the PremierWave to an Internet host, showing how many hops the packet requires to reach the host and how long each hop takes.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings Max Length Set the maximum length of the log.txt file. Note: This setting becomes available when Filesystem is selected. To Configure the Diagnostic Log Output Using Web Manager To configure the Diagnostic Log output, click Diagnostics in the menu and select Log.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings Using the CLI To enter the command level: enable, show processes Using XML Include in your file: Threads The PremierWave Threads information shows details of threads in the ltrx_evo task which can be useful for technical experts in debugging. To View Thread Information Using Web Manager To view thread information, click Diagnostics in the menu and select Threads.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings To Specify Clock Setting Method Using Web Manager To view thread information, click Clock in the menu. Using the CLI To enter the command level: enable -> config -> clock Using the XML Include in your file: System Settings The PremierWave System settings allow for rebooting the device, restoring factory defaults, uploading new firmware and updating a system’s short and long name.
PRELIMINARY DRAFT 13: Maintenance and Diagnostics Settings Using XML Include in your file: Discovery and Query Port The current statistics and configuration options for device discovery, including Query Port are available for the PremierWave. Table 13-13 Discovery Settings Discovery Description Query Port Server State Select to enable or disable the query port server from responding to autodiscovery messages on port 0x77FE.
PRELIMINARY DRAFT 14: Advanced Settings Email Settings View and configure email alerts relating to events occurring within the system. Table 14-1 Email Configuration Email – Configuration Settings Description Configure SMTP Click this link to configure SMTP: SMTP Settings (on page 77). To Enter the email address to which the email alerts will be sent. Multiple addresses are separated by semicolon (;). Required field if an email is to be sent.
PRELIMINARY DRAFT 14: Advanced Settings Using the CLI To enter Email command level: enable -> email 1 Using XML Include in your file: Command Line Interface Settings The Command Line Interface settings allow you to control how users connect to and interact with the PremierWave's command line. It is possible to configure access via the Telnet and SSH protocols, in addition to general CLI options.
PRELIMINARY DRAFT 14: Advanced Settings Telnet Settings The telnet settings control CLI access to the PremierWave over the Telnet protocol. Table 14-3 Telnet Settings Telnet Settings Description Telnet State Enable or Disable CLI access via telnet Telnet Port Enter an alternative Telnet Port to override the default used by the CLI server. Blank the field to restore the default. Telnet Max Sessions Specify the maximum number of concurrent Telnet sessions that will be allowed.
PRELIMINARY DRAFT 14: Advanced Settings To Configure SSH Settings Using Web Manager To configure SSH settings, click CLI in the menu and select Configuration. Using the CLI To enter the SSH command level: enable -> config -> cli -> ssh Using XML Include in your file: and XML Settings The PremierWave allows for the configuration of units using an XML configuration record (XCR).
PRELIMINARY DRAFT 14: Advanced Settings XML Export Configuration Settings (continued) Description Groups to Export Check the configuration groups that are to be exported to the XML configuration record. The group list should be comma delimited and encased in double quotes. The list of available groups can be viewed with the “xcr list” command. To Export Configuration in XML Format Using Web Manager To export configuration format, click XML in the menu and select Export Configuration.
PRELIMINARY DRAFT 14: Advanced Settings Using XML Not applicable. XML: Import Configuration Here you can import a system configuration from an XML file. The XML data can be imported from a file on the file system or pasted into a CLI session. The groups to import can be specified at the command line, the default is all groups. Import Configuration from External File This import option requires entering the path and file name of the external XCR file you want to import.
PRELIMINARY DRAFT 14: Advanced Settings Using XML Not applicable.
PRELIMINARY DRAFT 15: Security in Detail Public Key Infrastructure Public key infrastructure (PKI) is based on an encryption technique that uses two keys: a public key and private key. Public keys can be used to encrypt messages which can only be decrypted using the private key. This technique is referred to as asymmetric encryption, as opposed to symmetric encryption, in which a single secret key is used by both parties.
PRELIMINARY DRAFT 15: Security in Detail through any number of intermediate authorities, ultimately to the agent that needs to prove its authenticity. Obtaining Certificates Signed certificates are typically obtained from well-known CAs, such as VeriSign. This is done by submitting a certificate request for a CA, typically for a fee.
PRELIMINARY DRAFT 15: Security in Detail Steel Belted RADIUS Steel Belted RADIUS is a commercial RADIUS server from Juniper Networks that provides a GUI administration interface. It also provides a certificate request and self-signed certificate generator. The self-signed certificate has extension .sbrpvk and is in the PKCS12 format. OpenSSL can convert this into a PEM format certificate and key: openssl pkcs12 -in sbr_certkey.sbrpvk -nodes -out sbr_certkey.pem The sbr_certkey.
PRELIMINARY DRAFT 16: Updating Firmware Obtaining Firmware Obtain the most up-to-date firmware and release notes for the unit from the Lantronix Web site (www.lantronix.com/support/downloads/) or by using anonymous FTP (ftp://ftp.lantronix.com/). Loading New Firmware through Web Manager Upload the firmware using the device web manager System page. To upload new firmware: 1. Select System in the menu bar. The System page appears. Figure 16-1 Uploading New Firmware 2.
PRELIMINARY DRAFT 16: Updating Firmware device will automatically reboot afterwards. 6. Close and reopen the web manager internet browser to view the device’s updated web pages. Note: You may need to increase HTTP Max Bytes in some cases where the browser is sending data aggressively within TCP windows size limit when file (including firmware upgrade) is uploaded from webpage. Loading New Firmware through FTP Firmware may be updated by sending the file to the PremierWave over an FTP connection.
PRELIMINARY DRAFT 17: Branding the PremierWave XC HSPA+ This chapter describes how to brand your PremierWave by using Web Manager and Command Line Interface (CLI). It contains the following sections on customization: Web Manager Customization Short and Long Name Customization Web Manager Customization Customize the Web Manager's appearance by modifying index.html, style.css, and the product logo. The style (fonts, colors, and spacing) of the Web Manager is controlled with style.css.
PRELIMINARY DRAFT 17: Branding the PremierWave XC HSPA+ Short and Long Name Customization You can customize the short and long names in your PremierWave. The names display in the CLI show command and in the System web page in the Current Configuration table. The short name is used for the show command. Both names display in the CLI Product Type field. Table 17-1 Short and Long Name Settings Name Settings Description Short Name Enter a short name for the system name.
PRELIMINARY DRAFT Appendix A: Technical Specifications Network Cellular UMTS/HSPA+ (850/800/900/1900/2100 MHz) GSM/GPRS/EDGE (850/900/1800/1900 MHz) Transfer Rates - up to 14.4 Mbps (downlink), up to 7.2Mbps (uplink) 1 Secure SIM Slot 2 x Omni-Directional Penta-band Antennas Ethernet 10BaseT and 100Base-TX Link (auto sending full and half duplex support) RJ-45 Connector with LEDs (operation and activity) 1.
PRELIMINARY DRAFT USB Connector 1 x USB Type A Host Connector (USB 2.0) I/O Interface Input Connection: Sensors/Events Voltage acceptance: 0 to 30 VDC Digital input event: User configurable Optical: 1.
PRELIMINARY DRAFT Management Web Browser (SSL option for secure login) CLI (over serial ports, Telnet, or SSH) XML Configuration Records via CLI or FTP Supports SNMP version 2c Software Lantronix Device Server Application Suite DeviceInstaller. Power Input Voltage: 9-30 VDC Power Consumption: 3.6 Watts (typical) Power Supply (100 - 240 VAC, 50-60 Hz, 12 VDC @ 1.
PRELIMINARY DRAFT Dimensions Size: 9.4 cm (3.7 in) L x 10.9 cm (4.3 in) W x 3.0 cm (1.2 in) H Weight: 0.44 kg (1.
PRELIMINARY DRAFT Appendix B: Compliance (According to ISO/IEC Guide 17050-1, 17050-2 and EN 45014) Manufacturer's Name & Address: Lantronix, Inc. 167 Technology Drive, Irvine, CA 92618 USA Product Name Model: PremierWave XC HSPA+ This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
PRELIMINARY DRAFT Appendix B: Compliance Conforms to the following standards or other normative documents: Emissions FCC 15.107:2013 FCC 15.
PRELIMINARY DRAFT Appendix B: Compliance Manufacturer's Contact: Lantronix, Inc.
PRELIMINARY DRAFT Appendix C: Technical Support If you are unable to resolve an issue using the information in this documentation, please contact Technical Support: Technical Support US Check our online knowledge base or send a question to Technical Support at http://www.lantronix.com/support. Technical Support Europe, Middle East, Africa Phone: +33 13 930 4172 Email: eu_techsupp@lantronix.com or eu_support@lantronix.
PRELIMINARY DRAFT Appendix D: Binary to Hexadecimal Conversions Many of the unit's configuration procedures require you to assemble a series of options (represented as bits) into a complete command (represented as a byte). The resulting binary value must be converted to a hexadecimal representation. Use this chapter to learn to convert binary values to hexadecimals or to look up hexadecimal values in the tables of configuration options.
PRELIMINARY DRAFT Figure D-2 Windows Scientific Calculator 4. Click Hex. The hexadecimal value appears.
PRELIMINARY DRAFT Appendix E: USB-CDC-ACM Device Driver File for Windows Hosts The following file may be used to enable Windows to recognize the USB-CDC-ACM connection to the PremierWave's USB Device port. Create the linux-cdc-acm.inf file on the Windows host somewhere using the contents provided below. When Windows prompts for a device driver for the USB connection, point it to this file.
PRELIMINARY DRAFT Appendix E: USB-CDC-ACM Device Driver File for Windows Hosts ;----------------------------------------------------------------------; Vista-64bit Sections ;----------------------------------------------------------------------[DriverInstall.NTamd64] include=mdmcpq.inf CopyFiles=DriverCopyFiles.NTamd64 AddReg=DriverInstall.NTamd64.AddReg [DriverCopyFiles.NTamd64] USBSER.sys,,,0x20 [DriverInstall.NTamd64.AddReg] HKR,,DevLoader,,*ntkern HKR,,NTMPDriver,,USBSER.