Intrinsyc Open-QTM 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide [Document: ICS-01RND1278-TN-068 Revision: 1.1] NOTICE TO PERSONS RECEIVING THIS DRAWING AND/OR TECHNICAL INFORMATION INTRINSYC Technologies Corp. claims proprietary rights to the material disclosed hereon.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 Identification Document Title Intrinsyc Open-QTM 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Document Number ICS-01RND1278-TN-068 Version 1.1 Date May 15, 2019 History REVISION 1.0 1.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 Table of Contents 1. INTRODUCTION...................................................................................3 2. APPLICABLE MODULE .......................................................................3 3. ADDITIONAL REGULATORY CONFORMANCE TESTING AND/OR SUBMISSIONS REQUIRED BY THE INTEGRATOR .....................................3 4. COMPLIANT/ALLOWABLE TX POWER SETTINGS .................
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 1. INTRODUCTION This document describes the steps that the OEM integrator must follow when designing and manufacturing a system utilizing the Open-QTM 626 SOM Transmitter Module. Failing to follow the instructions in this document may invalidate the FCC and IC (Industry Canada) certifications and authorizations of the Module for use in the U.S. and Canada.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 5. ALLOWABLE ANTENNAS TO USE WITH THE RADIO MODULE The module is certified for use with certain antennas as described in this section. Allowed Antenna Types: 1. Dipole antenna Table 1 Allowed Maximum Gain (dBi) Dipole, Including Cable Loss 2.4~2.5GHz 3.32 4.9~5.8GHz 6.11 The required antenna impedance is 50 ohms.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 6. ANTENNA PLACEMENT AND RF SAFETY The FCC and other countries’ regulatory bodies impose strict conditions and limitations on the RF exposure levels of end products. Acceptable RF exposure levels for this Module depend on transmit power, the location of the transmitting antenna(s) inside the host system and the expected separation of the transmitting antennas to the end user.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 7. SIMULTANEOUS TRANSMISSION WITH OTHER INTEGRATED OR PLUG-IN RADIOS The FCC and IC impose conditions and limitations when additional radio(s) are co-located in the same host system as the Module with capability to transmit simultaneously.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 The FCC requires a logo signifying emission compliance on the outside of the host system. The OEM integrator is responsible to perform FCC Part 15 Class B digital emissions testing on the end system with the radio Module installed. The FCC logo below should not be affixed unless the OEM integrator has obtained the necessary Part 15 approval, e.g., selfdeclaration of conformity.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 10. REQUIRED LABELING ON THE MODULE 10.1 FCC and Industry Canada Labelling on the Module The OEM integrator must ensure that the FCC ID and IC number is affixed on the Module or in a User/Installation Manual along with other country certification numbers and logos as described herein. Note: the original Module manufacturer may affix regulatory labeling at time of Module manufacturing.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 11.2 Industry Canada Requirements for End User Manual / Installation Manual Industry Canada Statements This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 (iii)the maximum antenna gain permitted for devices in the bands 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and non point-to-point operation as appropriate. (iv) Users should also be advised that high power radars are allocated as primary users (i.e.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 3. The transmitter module may not be co-located with any other transmitter or antenna. As long as the conditions above are met, further transmitter tests will not be required. However, the OEM integrator is still responsible for testing the end product and any additional compliance requirements required with this module installed.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 Manuel d'information à l'utilisateur final L'intégrateur OEM doit être conscient de ne pas fournir des informations à l'utilisateur final quant à la façon d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final qui intègre ce module.
Intrinsyc Open-Q™ 626 (APQ8053) SOM Module Certification Technical Note 68: OEM Integrator Guide Rev. 1.1 12. OEM INTEGRATOR CHECKLIST The OEM Integrator will integrate the Module in the host systems in accordance with the instruction specified in this document and the documents referenced herein. The OEM Integrator will ensure the Module is integrated in a host system using only antennas that are of the same type and having equal or less antenna gain as described in this document.