Laney Series Mixer Amps MODEL : CD640 CD850S USER MANUAL
Intended to alert the user to the presence of uninstalled "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. Caution: Risk of electrical shock - DO NOT OPEN! Caution: To reduce the risk of electrical shock, do not remove cover. No user servicable parts inside.
Concept 1 THANK YOU We at Laney are extremely pleased that you have decided to select a Concept product for your sound requirements and we wish to reinforce your judgement by ensuring you get off to a flying start by including this comprehensive user manual to assist you in getting to know your equipment.
Concept 2 FRONT PANEL FEATURES: CD640 1 -0+ 1 2 1 3 4 5 5 1 -0+ 4 1 1 -0+ 2 3 Bass 4 5 Bass 6 3 4 8 1 4 5 1 4 8 2 1 4 5 1 4 8 1 9 4 8 10 0 4 Level Pad Level Pad 1 2 3 4 Line Line Line Line 4 8 0 6 10 7 10 Main EQ 8 9 10 +15 +3 0 Limiter Active 0dB 0dB -5 Main Bridged 10 0 5 4 6 3 6 8 9 10 0 Line2 5 4 6 3 7 1 Line1 -18 -15 60Hz 160Hz 400Hz 1KHz 2.
Concept 3 FEATURES CD640 CD640 Features - Channels 1 - 4 1 -0+ 2 1 3 4 4 5 5 1 -0+ 3 3 4 5 5 Mid 1 -0+ 3 3 4 4 Bass 4 4 MON: Controls the amount of signal sent from the channel to the ‘Monitor’ output socket, giving the user the versatility of a separate monitor mix. 5 5 6 3 7 8 2 1 9 10 0 Mon 4 5 5 FX: Controls the amount of signal sent by the individual channel to the onboard DSP section.
Concept 4 FEATURES CD640 CD640 Features - Channels 5 & 6 1 -0+ 2 1 2 4 4 5 5 1 -0+ 1 2 2 4 5 5 Mid 1 -0+ 3 3 4 4 Bass 4 5 5 6 3 7 4 MON: Controls the amount of signal sent from the channel to the ‘Monitor’ output socket, giving the user the versatility of a separate monitor mix. 8 2 1 9 10 0 Mon 4 5 6 3 7 8 2 1 9 4 5 FX: Controls the amount of signal sent by the individual channel to the onboard DSP section.
Concept 5 FEATURES CD640 CD640 Features - DSP 11 VOCAL: Selects the VOCAL effect from the onboard DSP. 11 to any channel with an FX setting of more than zero. Overall level of VOCAL DSP is controlled by the FX return controls for the MONITOR and MAIN power amp sections. Vocal 12 13 Large Hall 12 LARGE HALL: Selects the LARGE HALL reverb effect from Small Hall 14 the onboard DSP. to any channel with an FX setting of more than zero.
Concept 6 FEATURES CD640 CD640 Features - OUTPUT SECTION Monitor EQ +15 +15 +3 Power 0 18 0dB 0dB -15 4 5 6 3 19 4 8 Main EQ 6 31 8 9 10 +15 0dB 32 Phantom 48V 7 Master 1 Volume 0 +15 20 5 2 9 10 Off 3 7 0 On -10 -18 -15 60Hz 160Hz 400Hz 1KHz 2.5KHz 6KHz 16KHz FX 2 Return 1 -5 +3 0dB 0 Limiter Active -5 Main Bridged 30 -10 -15 -18 -15 60Hz 160Hz 400Hz 1KHz 2.
Concept 7 18 MONITOR EQ: 7 band graphic equalizer, for the ‘Monitor/Main’ section of the amplifier. This also acts as EQ for the line level ‘Monitor’ output socket. 19 FX RETURN: Controls the overall effects level of the on board DSP present in the monitor signal. 20 MAIN EQ: 7 band graphic equalizer, for the ‘Main’ section of the amplifier. This also acts as EQ for the line level ‘Main’ output socket. 21 FX RETURN: Controls the overall effects level of the on board DSP present in the main signal.
Concept 8 30 AMP MODE SELECTOR SWITCH: This selects the functions of the two power amp modules within the unit, whether bridged together as one mono amp (set switch to ‘Bridge’), running in dual mono mode, as two separate front-of-house amps (set switch to ‘Main-Main’), or running as two independent amps, one for the front-of-house mix, and one for the monitors (set switch to ‘Main-Mon’). 31 MASTER VOLUME: Determines the overall level sent to the monitor out.
Concept 9 FEATURES CD850S CD850S Features - Channels 1 - 6 1 -0+ 1 2 1 2 3 3 4 4 1 -0+ 1 2 2 2 3 3 4 5 5 1 -0+ 2 2 4 5 5 4 5 6 3 7 8 2 1 10 0 4 5 7 channel to the onboard DSP section. 8 2 1 9 10 0 FX 1 - 0+ 6 LEVEL: Adjusts the channel level, enabling the user to balance levels across channels. 1 2 2 3 3 4 4 5 5 Pan 4 5 6 3 7 8 2 1 9 0 7 to the ‘Monitor’ output socket, giving the user the versatility of a separate monitor mix.
Concept 10 FEATURES CD850S CD850S Features - Channels 7/8 - 9/10 -0+ 1 1 2 1 2 3 3 4 4 -0+ 1 1 2 2 3 3 4 -0+ 1 2 2 4 5 5 5 4 6 3 7 1 5 FX: Controls the amount of signal sent by the individual 10 0 5 4 6 3 7 8 2 1 9 10 0 1 - 0+ 1 2 2 3 3 4 4 4 channel to the onboard DSP section. The overall level of effects is controlled via the FX return controls for the Main and Monitor mix. See below.
Concept 11 FEATURES CD850S 36 LEFT EQ: 7 band graphic equalizer, for the LEFT channel of the Mixer amplifier. Laney 37 RIGHT EQ: 7 band Left EQ 36 +15 +15 0dB 0dB graphic equalizer, for the Right channel of the Mixer amplifier. 38 LEFT MASTER & -15 RIGHT MASTER: Determines the overall listening level of the left and right outputs of the mixer amplifier. -15 60Hz 160Hz 400Hz 1KHz 2.5KHz 6KHz 16KHz Right EQ 37 +15 +15 0dB 0dB -15 39 LEFT SEND: Socket -15 60Hz 160Hz 400Hz 1KHz 2.
Concept 12 FEATURES CD850S 0 LEFT RETURN: Socket provided for connecting the return signal from an external device connected to the LEFT SEND. 43 AUX IN: Stereo Aux socket. 44 MONITOR OUT: Line level signal provided for connecting to an external powered monitor or connecting to an external power amplier supplying un- powered monitors. The Level of signal present at this socket is determined by the individual MONITOR level of each channel.
Concept 13 50 TAPE IN: Dual phono, line level input sockets, ideal for connecting an external tape machine, CD player, etc. to the amplifier. 51 TAPE OUT:Dual phono, line level output sockets, ideal for connecting an external recording device. 52 FX RETURN: Stereo socket for output of external effects processing devices connected to FX send. 53 FX SEND: Socket for connecting external effects devices.
Concept 14 FEATURES CD850S 59 PHANTOM POWER +48V CAUTION RISK OF ELECTRIC SHOCK - DO NOT OPEN Warning To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture. CAUTION RISK OF ELECTRIC SHOCK - DO NOT OPEN ! Warning To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture.
BLT Industries Ltd., Newlyn Road, Cradley Heath, West Midlands. B64 6BE. Tel: (0044) (0)1384 633821 Fax: (0044) (0)1384 639186 Web site: http://www.laney.co.uk In the interest of continued product development BLT Industries Ltd. reserves the right to amend product specification without prior notification.