`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 12 Install new tamper seals over two screws using the plastic sleeve provided (optional). Figure 6.20 Rockwell/Equimeter/Sensus: center test dial, counter installed, or index 13 Utilize the RF Buster to verify module is transmitting, hold RF Buster with magnet side to the top upper left quadrant of the module plastic and hold the button until 10 beeps are received. See Appendix C, Using the RF Buster for more information.
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 1 Follow the steps in ʺTo Begin C&I Meter Module Installationʺ on page 6‐1. 2 Remove the tamper caps and index cover from the original meter. Remove all of the original gasket material. Clean the gasket surface on the meter with a wire brush and gasket scraper. 3 Open the package containing the Meter Module, screws, and battery. Figure 6.22 Sprague/Actaris: screw kit 4 Open the bag containing the battery. Carefully remove the battery.
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 10 Install the new gasket (if required) and index cover to the front of the index. Handle the index carefully. The torque requirement is 30‐40 inch pounds. The screws go through the index cover and bracket, and fasten into the meter. Ensure that the counter is aligned with proving dial (on top). Figure 6.23 Sprague/Actaris: installing Index cover 11 Install new tamper seals. Figure 6.
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 12 Utilize the RF Buster to verify module is transmitting, hold RF Buster with magnet side to the top upper left quadrant of the module plastic and hold the button until 10 beeps are received. See Appendix C, Using the RF Buster for more information. Figure 6.25 Sprague/Actaris: meter with module installed 13 Clean up any debris from the retrofit and installation processes and tie any loose cables with tie wraps.
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå Schlumberger/Actaris Meter Module Installation Figure 6.26 Schlumberger/Actaris: before installation Only Schlumberger meters with the taller base (shown above) can accommodate Cellnet Meter Modules. Meters with the shorter base (shown below) will need to be retrofitted with a taller index bracket prior to module retrofit. Figure 6.
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 2 Remove the tamper caps and index cover from the original meter. Remove the gasket if it is unserviceable. Clean the work areas with a wire brush or scraper as needed. Figure 6.28 Schlumberger/Actaris: Index cover removed 3 Open the package containing the Meter Module, screws, and battery. 4 Open the bag containing the battery. Carefully remove the battery. 5 Open the Meter Module, taking care to avoid pulling on the cables.
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 10 Attach the bracket and Meter Module to the meter. Note the order of installation: index cover, bracket, tamper cap, and screw. The torque requirement is 30‐40 inch pounds. Figure 6.29 Schlumberger/Actaris: meter with bracket and meter module 11 Install new tamper caps over the screws using the plastic sleeves provided.
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ SJNV
`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå Notes: SJOM `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
CHAPTER 7 CELLNET PULSE RECORDER METER MODULE INSTALLATION TOOLS AND EQUIPMENT This section outlines the necessary tools and equipment for installing a Cellnet Pulse Recorder. Equipment The following table contains all required equipment: Image Table 7.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå Image Description açï=`çêåáåÖ=lpJO=páäáÅçåÉ=`äÉ~åÉê=Eçê=Éèìáî~äÉåíF jpap=~î~áä~ÄäÉ=~í=ïïïKÇçïÅçêåáåÖKÅçãK mfkJfkJqlou oÉèìáêÉë=~=qlou=ÇêáîÉê=ëáòÉ=qNM=ïáíÜ=~=ÜçäÉ=Ñçê=íÜÉ=mfk ^ÇÇáíáçå~ä=Å~ÄäÉ péÉÅáÑáÅ~íáçåW=OOJ^td=pçäáÇ=`çééÉê `çäçêëW=oÉÇLdêÉÉåL_ä~Åâ ms`=g~ÅâÉí t~ääJãçìåí=háí=mkW=QRJMMVM çê OJPÒ=máéÉJjçìåí=háí=QRJMMUM pÅêÉïë=Ñçê=ãÉíÉê=áåÇÉñÉë TJO `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå Tools The following table contains all required tools: Image j~ÖåÉí= äçÅ~íÉÇ=çå= íçé=äÉÑí Table 7.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå SAFETY AND ENVIRONMENT Prerequisite Training Installers should be instructed in the following safety elements as well as any site‐ specific safety issues: • Hazard Communication (Employee Right to Know) • Lifting • Safe driving • Use of hand tools • Confined space Preliminary Checks The installer should already be able to operate the HandHeld computer.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå FCC INFORMATION See Appendix F, CPR Information, for more information. INSTALLING THE CELLNET PULSE RECORDER The following includes information about installing the CPR endpoint. Mounting the CPR The CPR endpoint should be mounted above ground, outdoors, facing the nearest concentrator. Identifying the Register for Installation Refer to the Gas Module Compatibility Chart for compatibility and specific parts needed.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå CPR ships with a female Molex connector at the loose end of the communication cable. b Before proceeding with splicing, use the Wire Cutter and Stripper to cut the Molex connector off of the CPR Pulse Input Connector (identified by white wire). CPR Pulse Input Connector with white wire Figure 7.2 Molex Connector (as shipped) c TJS Splice wires from CPR to PRECO switch. Match colors carefully, according to the table below.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå Table 7.3 Wire Color Matching PRECO Wire color/CPR Wire Color Encoder Register PRECO blue to green extension to CPR white blue white red red white black PRECO red to red extension to CPR red PRECO white to black extension to CPR black Connect only three wires using the color matching above. 4 See Appendix A: Crimping Wires, for instructions on crimping wires.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 4 Connect the battery to the CPR. 5 Dress the wires and crimp inside the CPR enclosure as shown. Crimped Wires CPR Serial/Power Connector Tie Wrap Battery Connector Figure 7.4 CPR Battery Connector Connected to CPR Proceed to ʺTesting the Endpointʺ on page 7‐8. TESTING THE ENDPOINT After you have completed the installation process, test the installation by passing an RF Buster magnet near the CPR’s sensor.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå 2 Press and hold the button on the RF Buster. Position the RF Buster less than six inches away from the left side of the CPR. The RF Buster makes audible beeps and the LED flashes to confirm transmission of the RF packets from the endpoint. Do not use a cell phone or any other RF device while conducting this test. 3 If the RF Buster detects packets within one minute, the installation is good.
`ÉääåÉí=mìäëÉ=oÉÅçêÇÉê=jÉíÉê=jçÇìäÉ=fåëí~ää~íáçå TJNM `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
CHAPTER 8 METER EXCHANGE OR MODULE RETROFIT CONCLUSION Prior to leaving the premise, verify that all debris from the retrofit and/or exchange process is cleaned and removed. Leave a door hanger tag with any appropriate information filled in. RETURNING MATERIAL At the end of the day, installers will return to the Cross Dock with all equipment and any new meters or modules that were not installed. Each installer must account for every meter they were assigned.
jÉíÉê=bñÅÜ~åÖÉ=çê=jçÇìäÉ=oÉíêçÑáí=`çåÅäìëáçå Notes: UJO `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
CHAPTER 9 GAS METER PREPARATION PROGRAM (GPREP) The Gas Meter Preparation Program (GPrep) is a software tool that facilitates Cellnet processes. It also runs with water CPR modules. The data captured by GPrep is sent to RIMS to update the Cellnet and utilities databases.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF processes. This chapter assumes that the user fully understands these O&M processes, and at which steps in these processes GPrep captures data and programs it into Cellnet modules. GPrep requires selective functionality depending on the site where it is in use, so there are administrative privileges for configuring options during software installation and setup.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF REQUIRED TOOLS The following is a list of required tools to operate GPrep, along with a PC / operating system recommendation: • Desktop PC with Windows 2000 or higher (Windows NT is not recommended when using a laptop computer since there are sometimes problems configuring the ports) • Copy of GPrep v. 2.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF • If this is an upgrade, then you can use the existing GPREP.INI file to modify any configuration parameters as necessary. b Edit the GPREP.INI file using Notepad or any other ASCII file editor. c Follow the instructions in that file to specify the required pattern for Meter IDs, file(s) for logging operations, menu selections that are available to the operator and the maximum memory used to track previous log file associations.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF ; Disables "Re-Program Old" and "MRB" selections, leaving "Inspect", ; "Program New" and "Index Read" modes enabled. ; ----------------------------------------------------------------------------; Operator Port selections are controled by variables: ; ; COM1, COM2, COM3 and COM4 ; ; Setting any of these to "No" disables the menu item. The default is "Yes".
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF ; ; Examples: ; ; InspectLog=c:\gprep\inspect.txt - inspect.txt in the gprep directory on drive C: ; InspectLog=inspect.txt - inspect.txt in the GPrep program directory ; InspectLog=inspect - inspect.txt in the GPrep program directory ; InspectLog=- Do not write an inspection log file ; ----------------------------------------------------------------------------; MRBLog is the full path and file name for logging each time a module is ; inspected in MRB Mode.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF MeterConstant0=0.020000 RolloverPoint3=100000 MeterConstant3=1.000000 RolloverPoint2=100000 MeterConstant2=0.100000 MeterConstant4=0.250000 ProgramMode=Yes ProgramDial=Yes RolloverPoint=100000 MeterConstant=1.000000 LastFile=WCPR.SET [Control] meterID=????????? DeviceID=????? RGAS=yes CIGD=yes CIGR=yes CPRANT=yes CPRAWT=yes CPRCWT=yes WCPR=yes Inspect=yes ProgramNew=yes ProgramOld=yes MRBMode=yes IndexRead=N ProgramLog=c:\programlog.txt inspectLog=c:\inspectlog.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF MeterConstant8=.112 MeterConstant9=1.0 RollOverPointCount=6 RollOverPoint1=100 RollOverPoint2=1,000 RollOverPoint3=10,000 RollOverPoint4=100,000 RollOverPoint5=100,00000 RollOverPoint6=100,000000 [CPRANT] MeterConstantCount=10 MeterConstant1=.01 MeterConstant2=.01121 MeterConstant3=.02 MeterConstant4=.0225 MeterConstant5=.05 MeterConstant6=.0562 MeterConstant7=.1 MeterConstant8=.112 MeterConstant9=1.0 MeterConstant10=2.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF RollOverPoint5=100,0000 [CIGD] MeterConstantCount=5 MeterConstant1=.05 MeterConstant2=.0562 MeterConstant3=.1 MeterConstant4=.112 MeterConstant5=1.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF USING GPREP This section details the steps taken by the end user to operate GPrep on a daily basis. This set of procedures assumes the following: • Your GPrep administrator has configured the .ini file. • You have basic knowledge of the process that you are trying to perform and understand at which step of the process you need to use GPrep.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF Logging On The Log On window displays when you launch the program. Enter your name and location in the appropriate fields. All tasks you perform for a given meter type (module inspection, new module programming and old module reprogramming, MRB and index read) will be recorded. Figure 9.3 Log On screen Accessing the Main Menu The main menu screen displays after you log on. Figure 9.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF • Inspect: Verifies that the programmed LAN Address has the same value as the Power LAN Address label. In addition, “Inspect” permits validating the other pre‐configured operational parameters. Discrepancies are noted through message windows and the results of inspections are captured in associated files. The unique meter ID format for a given utility is defined in the “.ini” file.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF Figure 9.5 Choose ResGas as the meter type Figure 9.6 Indicate the Program Type Figure 9.7 Modes to choose from are “Inspect” or “Program New” • Control: provides the capability to log on and off. The program setting remains the same when a new operator logs on. • Help: provides a description of GPrep functionality for each mode of operation (not yet fully implemented).
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF MODULE INSPECTION This feature is most commonly used when receiving meters from the factory with Cellnet modules already installed (OEM Meters) or when receiving Cellnet modules from Cellnet’s manufacturer. Different utilities use different sampling procedures. Cellnet recommends that the meter shop verify a percentage of inbound modules to ensure that the LAN Address that is programmed into the module matches the LAN Address on the outside of the module housing.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF The lower section, “ current parameters”, displays the operational parameters and module programmed values. 2 Connect the shooter cable to the module programming port. The following screen displays. Figure 9.9 “Inspect Mode” Screen With Module Plugged In GPrep automatically reads and displays the current parameters programmed into the module.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF 3 Scan (enter) the Module ID in LAN Address field. Figure 9.10 “Inspect Mode” With Power LAN Scanned In GPrep compares the Module ID entered in this field with the LAN Address programmed into the module. If the populated field matches the programmed value, a message displays “address verified”.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF MODULE PROGRAMMING There are two modes for programming the modules. Program New is used when a module is installed on a new meter with an index that reads zero, and Re‐ program old is used for programming a module that is being installed on a meter that has an index with a value other than zero. This value is programmed into the module to log in the starting read for a meter to be installed.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF 2 Connect the 1‐Way Programming Cable or shooter cable to the module programming port. The following screen displays. Figure 9.12 “Program New” Screen with Module Plugged In GPrep automatically reads and displays the current parameters programmed into the module. If the Meter Type selected on the menu bar does not match the module type under test, GPrep displays a dialog box indicating “wrong module Type” and a blinking “Module reject” message.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF either rescan or re‐enter the meter ID value in this field. Module programming can not be resumed until the meter ID field populated matches the utility specific format. Figure 9.13 Error Message Displayed when The Wrong Meter ID Format Is Entered 4 Scan (enter) the power LAN label in the LAN Address field. “GPrep” compares the value entered in this field with the LAN Address programmed in the module.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF Upon successful programming, a message “program verified” displays. GPrep also displays a green square indicator at the lower left corner of the screen showing programming has been successful. Figure 9.15 Display when parameters are verified A record of the meter and module association is automatically captured in the “program file” including the date and the operator’s name. The “Programlog” only compiles the records when successful programming is verified.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF • If a record already exist in the programlog for a scanned module Power LAN Address, GPrep displays the following message: Figure 9.17 Duplicate Power LAN Address • If you select“yes”, indicating that you entered the wrong module ID, then re‐ enter the meter ID field and Power LAN Address to correct possible mis‐ entered values. • If you select “No”, indicating the module ID has been entered correctly, GPrep displays a blinking message “route to MRB”.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF • Meter ID field • LAN Address • Dial • Roll‐over point • Meter constant These are the only fields that can be populated. 2 Connect the 1‐Way Programming Cable or shooter cable to the module programming port. The following screen displays. Figure 9.19 Re-Program Old With Module Plugged In GPrep automatically reads and displays the current parameters programmed into the module.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF this field does not match the specified utility format, a dialog window displays indicating “meter ID field contain invalid characters” and the operator is instructed to either rescan or re‐enter the meter ID value in this field. Module programming can not be resumed until the meter ID field populated matches the utility specific format. 4 Scan (enter) the Module ID in LAN Address field.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF Select the proper Meter Constant from the drop down box. You can typically determine the Meter Constant from the meter index. Upon successful programming a message “program verified” displays. GPrep also displays a green square indicator at the lower left corner of the screen showing that the programming has been successful (this is the same as the “verified” screen for Program New).
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF 3 Connect the 1‐Way Programming Cable or shooter cable to the module programming port. The following screen displays. Figure 9.22 MRB Screen with Module Plugged In If the Meter Type selected on the menu bar does not match the module type under test, GPrep displays a dialog box indicating “wrong module Type” and a blinking “Module reject” message. GPrep does not allow the operator to resume programming function.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF Figure 9.23 Error Message Displayed when Entered Value Does Not Match Programmed Value If you select “Yes”, GPrep displays a blinking message stating “Dial discrepancy” and the main screen displays that the new dial value has been logged in MRBlog. This is captured in the MRBlog as “dial Entered”. GPrep does not capture the old value that was programmed into the module. If you select “No”, GPrep prompts the operator to enter the correct value.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF MOST COMMONLY ASKED QUESTIONS 1 What does GPrep stand for? Gas TOMM Preparation 2 What is GPrep used for? GPrep is a tool that is used in the Cross Dock or meter shop to program gas or water CPR modules without the use of a handheld. It is also used to disassociate gas or water CPR modules from meters. 3 What is programmed into the module? In the ʺProgram Newʺ and ʺRe‐Program Oldʺ modes, field operating parameters are programmed into the module.
d~ë=jÉíÉê=mêÉé~ê~íáçå=mêçÖê~ã=EdmêÉéF 9 How soon does the data get updated in each system after a module is programmed? A CRON job runs nightly that picks up the data that is put on the Cellnet server and transfers it to RIMS. At a minimum there is a one day delay. 10 Why shouldn’t I take GPrep to the field? Data management becomes difficult when the PC that GPrep is being used on is not at a fixed location.
APPENDIX A ALIGNING THE NEW AMERICAN METER DRIVE DOG Cellnet modified the module wiggler in May 2005. The module wiggler now has a slightly different interface to the meter drive dog. Figure A.1 Meter Drive Dog aligned with 2 ft. module wiggler Insert one of the new protruding pins through the hole of a 2‐foot drive wiggler. Figure A.2 Meter Drive Dog aligned with 1 ft. module wiggler Insert one of the new protruding pins through the hole of a 1‐foot drive wiggler.
^äáÖåáåÖ=íÜÉ=kÉï=^ãÉêáÅ~å=jÉíÉê=aêáîÉ=açÖ Notes: ^JO `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
APPENDIX B VISUAL INSPECTION OF INDEXES The American Index on far right shows signs of fading from glossy black to a grey black color, in this case the Index MUST BE EXCHANGED. Figure B.1 Fading American Index On a Sprague meter if metal rivets are found on the index plate as shown on the far left the Index MUST BE EXCHANGED. Figure B.
sáëì~ä=fåëéÉÅíáçå=çÑ=fåÇÉñÉë Notes: _JO `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
APPENDIX C USING THE RF BUSTER This Appendix provides detailed instructions on the proper use of the RF Buster. It covers the proper placement of the RF Buster to ensure activation and troubleshooting for Cellnet gas modules. REQUIRED TOOLS RF Buster ‐ part number 26‐1050 Before using the RF Buster, test it. Press the button on the RF Buster. The RF Buster’s LED lights red, and the internal speaker sounds for approximately ½ second.
rëáåÖ=íÜÉ=oc=_ìëíÉê RESIDENTIAL METER MODULES American Modules 1 Press the button with the light facing you on the lower end of the RF Buster. 2 Place the corner of the RF Buster containing the magnet by the location of the Reed Switch on the Meter Module. 3 Continue to press the button. Hold the RF Buster within about six inches of the meter. The magnet triggers ten RF transmissions from the gas module, separated by one second each transmission.
rëáåÖ=íÜÉ=oc=_ìëíÉê If the RF Buster does not detect a transmission from the module, remove the four cover screws and place the RF Buster in the proper location. While holding the Push Button, pull the cover off of the module. • If the module is functional, it transmits. • If the RF Buster does not respond, consider the module defective and follow the appropriate procedure. Figure C.
rëáåÖ=íÜÉ=oc=_ìëíÉê • If the RF Buster does not respond, consider the module defective and follow the appropriate procedure. Figure C.
rëáåÖ=íÜÉ=oc=_ìëíÉê COMMERCIAL GAS 3 METER MODULES 1 Press the button with the light facing you on the lower end of the RF Buster. 2 Place the corner of the RF Buster containing the magnet by the location of the Reed Switch on the Meter Module. 3 Continue to press the button. Hold the RF Buster within about six inches of the meter. The magnet triggers ten RF transmissions from the RF Buster, separated by one second each transmission.
rëáåÖ=íÜÉ=oc=_ìëíÉê ROOTS/ROMETS ROTARY CPR MODULE 1 Press the button with the light facing you on the lower end of the RF Buster. 2 Place the corner of the RF Buster containing the magnet by the location of the Reed Switch on the CPR. 3 Continue to press the button. Hold the RF Buster within about six inches of the CPR. The magnet triggers ten RF transmissions from the CPR, separated by one second per transmission.
APPENDIX D END OF DAY HANDHELD INSTRUCTIONS This Appendix provides detailed instructions on docking the Handheld, power requirements, and how to change the Handheld ID. This information should only be used by experienced users. DOCKING THE HANDHELD At the end of the day (and at other times for various reasons), dock the Handheld to upload meter installation data and plug it in to recharge the battery. 1 Select DOCK from the functions screen. Figure D.
båÇ=çÑ=a~ó=e~åÇÜÉäÇ=fåëíêìÅíáçåë 3 After data has been uploaded, plug Handheld into charging cable. Figure D.2 Handheld DAP charging POWER REQUIREMENTS Never allow the battery to die completely. Although the route data saves to the flash memory card, there is no EPROM memory in the Handheld. You will have to reload the code and re‐calibrate the battery. Do not remove the battery. The batteries are not made to be replaced as with the other Handheld’s.
båÇ=çÑ=a~ó=e~åÇÜÉäÇ=fåëíêìÅíáçåë HOW TO CHANGE THE HANDHELD ID Occasionally the Handheld ID may be entered incorrectly or the wrong Handheld ID may be in a Handheld because of a memory card exchange. This section tells how to change the Handheld ID to the correct number. 1 Place the Handheld in the cradle and dock it. 2 Open up the most recent version of Handheld Edit. 3 Select “Communication” then “Transfer Files” from the menu on Handheld Edit.
båÇ=çÑ=a~ó=e~åÇÜÉäÇ=fåëíêìÅíáçåë Notes: aJQ `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
APPENDIX E DIFFICULT/NON-COMPATIBLE COMMERCIAL RETROFITS This Appendix provides detailed instructions on installing commercial gas modules in difficult settings, as well as non‐compatible module installations. . INDEX BASE PLATES WITH INTEGRAL SEAL CAPS 1 Meters encountered with the index base plate (Figure E.1) require the base plate replaced with one that does not have integral “towers”. The American Meter part number for a Base Plate with no towers for Diaphragm meters is 48828P038. Refer to www.
aáÑÑáÅìäíLkçåJÅçãé~íáÄäÉ=`çããÉêÅá~ä=oÉíêçÑáíë Pressure Tabs Meters with Pressure tabs on the surface near the Index must be retrofitted in such a way that access to the pressure tap is not comprised. mêÉëëìêÉ=q~é=äçÅ~íáçå=mäìÖ=ãìëí= ÄÉ=êÉãçîÉÇ=~åÇ=éêÉëëìêÉ=ëÉåëçê= áåëí~ääÉÇK Figure E.2 Meters with Pressure Tabs Figure E.2 indicates the locations of the pressure tap plugs that will be found on large meters. Figure E.3 shows a meter with an installed pressure fitting, a “Pete’s Plug”.
aáÑÑáÅìäíLkçåJÅçãé~íáÄäÉ=`çããÉêÅá~ä=oÉíêçÑáíë For all of these meters the transmitter portion of the module needs to be mounted so that access is still available to the pressure tap, as shown in Figure E.4. Figure E.
aáÑÑáÅìäíLkçåJÅçãé~íáÄäÉ=`çããÉêÅá~ä=oÉíêçÑáíë Reverse Loop Installations Some meters will be installed with the piping reversed from the preferred orientation. In these cases the index is reversed to face the back of the meter. It is extremely important in these cases that the Base Plate be mounted such that the index drive from the meter be centered in the hole in the Base plate. See Figure E.5 for an example of the insert base plate mounted backwards. Figure E.
aáÑÑáÅìäíLkçåJÅçãé~íáÄäÉ=`çããÉêÅá~ä=oÉíêçÑáíë Protective Index Enclosures Cellnet Commercial Gas Modules are not compatible with meters that use protective enclosures over the indexes (Figure E.7). Figure E.
aáÑÑáÅìäíLkçåJÅçãé~íáÄäÉ=`çããÉêÅá~ä=oÉíêçÑáíë Notes: bJS `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
APPENDIX F CPR INFORMATION Use this process to crimp wires for the Cellnet Pulse Recorder. CRIMPING WIRES 1 Push the wires to be connected as far as possible into the Scotchlok connector. Figure F.1 Wires Pushed into Scotchlok Connector 2 Place the Scotchlok connector (with wires) into the jaws of the crimping tool. Figure F.2 ScotchLok Connector in Crimping Tool Jaws Always use 3M Parallel Jaw Crimping Tool 3M Model E‐ 9Y or equivalent.
`mo=fåÑçêã~íáçå 3 Crimp the Scotchlok connector by squeezing the handles until it discharges gel. Continue to apply pressure for three seconds. Figure F.3 Crimped Scotchloks Discharge Gel 4 Place two plastic cable ties on wires and tighten securely for strain relief. Remove excess cable tie with wire cutters. mä~ëíáÅ=qáÉë Figure F.
`mo=fåÑçêã~íáçå 5 For splice connections outside the CPR enclosure, insert the entire splice assembly into the silicone‐filled splice enclosure. Close the cover with leads exiting alternate sides. Figure F.5 Inserting Splice Assembly into Silicone-filled Splice Enclosure The 3M Gel splice connector is NOT reusable. Replace the splice if necessary. Cellnet strongly recommends a splice enclosure for all CPR applications.
APPENDIX G FCC AND IC COMPLIANCE FCC CLASS B This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part J5 of the FCC Rules.
FCC and IC Compliance Commercial Gas 3 meter modules include the following internal and external labeling to comply to FCC and Industry Canada requirements: • Cellnet Model: printed on a label permanently affixed and laminated to the surface of the Printed Circuit Board internal to the unit • FCC m: R7PEC6R3S2 (visible on the label on the top of the unit's main plastic housing and printed on a label permanently affixed and laminated to the surface of the Printed Circuit Board internal to the unit) • Indust
Reader’s Comment Form Cellnet Gas Meter and Module Installation Guide (CO‐0089‐GB‐07.07) Please use this form only to identify publication errors or to request changes in publications. Your comments assist us in improving our publications. Direct any requests for additional publications, technical questions about systems, changes in support, and so on, to your Cellnet sales representative.