Certification Exhibit FCC ID: TEB-HUNTSU825 FCC Rule Part: 15.247 ACS Project Number: 12-0333 Manufacturer: Landis+Gyr Technologies, LLC Model: 0825 5015 B.U.
Draft 5.8.
Draft 5.8.13 Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr.
5.8.13 GridstreamDraft RF S4e Endpoint with ZigBee Data Sheet General The Gridstream RF S4e endpoint is designed to accommodate Landis+Gyr S4e poly-phase meters for use in commercial and light industrial services. The S4e Advanced Function meter is an Active Energy kWh/kW/TOU Meter. The meter features Digital Multiplication Measurement Technique, meets ANSI standards for performance and utilizes ANSI C12.19 protocol (between meter and AMR device). Can be deployed with or without ZigBee. Figure 1.
Draft 5.8.13 Gridstream RF S4e Endpoint with ZigBee Data Sheet Landis+Gyr Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
Draft 5.8.13 Landis+Gyr Gridstream RF S4e Endpoint with ZigBee Data Sheet Le présent émetteur radio (5931A-HUNTSU825) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
Draft 5.8.13 Gridstream RF S4e Endpoint with ZigBee Data Sheet Landis+Gyr Communication Module Specifications Table -1. Gridstream RF S4e Communications Module Specifications Category Compatible Meters Specification Value or Range Landis+Gyr S4e Supported Meter Forms RF ZigBee Standards Compliance 6 Class Form Class 3S 20 16SE 320 5S/45S 20 16/15K 480 6S/36S 20 9S/8S 20 2S 200 12S 200 16S/15S 200 25S 200 12SE 320 Voltage 10.5-13.
Draft 5.8.13 Landis+Gyr Gridstream RF S4e Endpoint with ZigBee Data Sheet Table -1.
Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Publication: 98-1245 Rev AA LANDIS+GYR CONFIDENTIAL INFORMATION
Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr.
Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Overview This publication outlines the procedure for remote passive antenna installation on Gridstream RF Electric Endpoints. Figure 1. Remote Passive Antenna This antenna couples radio frequency energy from a Landis+Gyr Gridstream RF Electric Endpoint's 902-928 MHz antenna into a coax cable connected to a remote antenna located at an optimal location for better connection to the Gridstream RF network. Coupling loss (including the 2.5 ft.
Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Required Materials The following materials are required to complete a remote antenna installation.
Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Performance Table 1. Performance Parameter Minimum Frequency 902 Typical Maximum Units 928 MHz 9 dB Coupling Loss 5 Polarization Linear VSWR 1.78:1 Impedance 50 ohm Input RL 11 dB Condition Final antenna assembly on FOCUS AX: modular Final antenna assembly on FOCUS AX: modular General Installation Guidelines Determine the optimum location for remote antenna installation.
Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Gridstream RF Enhanced FOCUS AX/AX-SD Mounting Procedure NOTE: The passive antenna should be mounted within 5 mm (0.25") of the indicated location to achieve specified performance. 1. Clean the meter cover where the flex antenna will be installed. Wipe the cover mounting area with an alcohol wipe and let the area dry for one minute before proceeding with the installation. 2.
Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Gridstream RF Enhanced S4e Mounting Procedure NOTE: The passive antenna should be mounted within 5 mm (0.25") of the indicated location to achieve specified performance. 1. Clean the meter cover where the flex antenna will be installed. Wipe the cover area with an alcohol wipe and let the area dry one minute before proceeding with the installation. 2.
Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Align the antenna center point on the meter housing at the 2:30 o’clock position, 1.5 cm clockwise past the nub on the outer meter cover Figure 5. Installation On Gridstream RF Enhanced S4e Meters Gridstream RF Integrated FOCUS AX/AX-SD Mounting Procedure NOTE: The passive antenna should be mounted within 5 mm (0.25") of the indicated location to achieve specified performance. 1.
Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide 6. Install the remote antenna at the location indicated by the link assessment performed. If a link assessment tool is not available, select a location that provides the best line of sight to the nearest collector. 7. Once installed to the antenna, wrap the connector using cold flow tape. Tape should be wrapped tightly and in a continuous manner. The tape should cover the cable one inch past the end of the connector. 8.
Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Antenna Brackets and Antenna Mounting Figure 8. Typical Remote Antenna Brackets 10 NOTE: To mount these brackets, use screw and bolt hardware that is approved by the local utility.
Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Grommet installed here, use RTV to Seal the meter can. Figure 9.