Rev. 3.0.2 Item no.
1. Important safety instructions 1. Important safety instructions Before using the device, be sure to carefully read the Safety Instructions. Keep this document with the device at all times. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Read these instructions. Keep these instructions Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Do not block any ventilation openings.
3. Warnings To completely disconnect this equipment from the AC mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power supply cord shall remain readily operable. Français: Pour démonter complètement l’équipement de l’alimentation générale, démonter le câble d’alimentation de son réceptacle. La prise d’alimentation restera aisément fonctionnelle. To reduce risk of fire or electric shock, do not expose this apparatus to rain or moisture.
EMC 2006/95/EC 2014/30/EU EN55032, Class A, EN55103-1, E4. E4 PLM+ SERIES Quick Start Guide rev 3.0.
PLM+ SERIES Quick Start Guide rev 3.0.
1. 安全に関する注意事項 1. 安全に関する注意事項 本装置を使用する前に、必ず安全のための注意事項をご一読ください。この書類は、常に装置と一緒に保管してください。 1. 注意事項をお読みください。 2. 注意事項の書類は手の届くところに保管しておいてください。 3. 全ての警告をお守りください。 4. 全ての指示に従ってください。 5. 本機器は水の近くで使用しないでください。 6. 掃除には、乾いた布のみを使用してください。 7. 22. ネットワーク・ケーブルを使用する場合、US National Differences 16.3 項は、VW -1 の難燃対応品を使用することを義務づけています。 2. 規格 換気口は塞がないようにしてください。製造者の指示に従って設置し 本機器は、E M C(E uropean E lectro-M agnetic C ompatibility: E U 電磁両立性)指令 2014/30/EU および 低電圧指令 2014/35/EU の必須要求事項に準拠して います。 てください。 8.
3. 警告 機器を電源から完全に遮断するには、電源プラグをコンセントから抜いてくだ 3.4.3 電波障害 さい。電源ケーブルの電源プラグは常に容易に抜き差しできるようにしてくだ 本装置のサンプルは European Electro M agnetic Compatibility(EM C)directive さい。 の制限事項に適合するための試験に合格しています。また、本装置は FCC 基準 Français: Pour démonter complètement l’équipement de l’alimentation Part 15 に準ずる Clas s B デジタル機器の制限事項に適合するための試験に合 générale, démonter le câble d’alimentation de son réceptacle. La prise d’alimentation restera aisément fonctionnelle.
1. Instructions de sécurité importantes 1. Instructions de sécurité importantes Avant d'utiliser l'appareil, veillez à lire attentivement les instructions de sécurité. Conservez constamment ce document avec l'appareil. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Lisez ces instructions. Conservez ces instructions. Tenez compte de tous les avertissements. Suivez toutes les instructions. N’utilisez pas cet appareil avec de l’eau à proximité.
3. Avertissements Pour totalement isoler l’équipement de l’alimentation secteur, débranchez le cordon d’alimentation de son embase. La fiche secteur du cordon d’alimentation doit rester accessible. Pour réduire les risques d’incendie et de choc électrique, n’exposez pas cet appareil à la pluie ou à l’humidité. N’exposez pas ce système/appareil au ruissellement ni aux éclaboussures et assurez-vous qu’aucun objet contenant du liquide, tel qu’un vase, n’est placé sur l’appareil.
1. Wichtige Sicherheitshinweise 1. Wichtige Sicherheitshinweise Lesen Sie bitte diese Sicherheitsanweisungen sorgfältig, bevor Sie das Gerät verwenden. Bewahren Sie dieses Dokument bitte jederzeit zusammen mit dem Gerät auf. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Bitte lesen Sie diese Anweisungen. Bitte bewahren Sie diese Anweisungen auf. Beachten Sie alle Warnhinweise. Folgen Sie bitte allen Anweisungen. Verwenden Sie dieses Gerät nicht in der Nähe von Wasser.
3. Warnungen Um das Gerät vollständig vom Stromnetz zu trennen, müssen Sie den Netzstecker des Gerätes aus der Steckdose ziehen. Der Netzstecker des Gerätes sollte jederzeit zugänglich sein. Français: Pour démonter complètement l’équipement de l’alimentation générale, démonter le câble d’alimentation de son réceptacle. La prise d’alimentation restera aisément fonctionnelle.
1. Instrucciones importantes de seguridad 1. Instrucciones importantes de seguridad Antes de usar este aparato, asegúrese de leer completamente estas Instrucciones de seguridad. Conserve este documento junto con el dispositivo. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Lea estas instrucciones. Conserve estas instrucciones Cumpla con lo indicado en los avisos. Siga todas las instrucciones. No utilice este aparato cerca del agua. Límpielo solo con un trapo seco.
3. Precaución Para desconectar este aparato completamente de la corriente eléctrica, extraiga el enchufe del cable de alimentación de la salida de corriente. Por este motivo, coloque el cable de forma que siempre pueda acceder a él. Français: Pour démonter complètement l’équipement de l’alimentation générale, démonter le câble d’alimentation de son réceptacle. La prise d’alimentation restera aisément fonctionnelle.
4. Table of Contents 4. Table of Contents 1. Important safety instructions 3 2. Approvals 3 3. Warnings 3 3.1. Explanation of warning symbols 3 3.2. Warnings 3 3.3. Caution 4 3.4. User responsibility 4 3.4.1. Mains connection grounding 4 3.4.2. Speaker output hazard on amplifiers 4 3.4.3. Radio interference 4 3.4.4. Speaker damage 4 3.4.5. Maintenance 4 5. Introduction 17 5.1. Welcome 17 6. Feature summary 17 6.1. Amplifier Platform Features 17 6.2.
4. Table of Contents 9. Operating voltage 9.1. Low voltage country considerations 20 21 10. Grounding 22 11. Product overview 22 11.1. Front panel 22 11.2. Rear panel 24 12. Signal flow and processing 26 13. Quick Start Tutorial 27 13.1. Network setup 27 13.1.1. Network connections / topology 27 13.1.2. Network configuration 27 13.2. Software installation and firmware update 28 13.2.1. Lake Controller software suite 28 13.2.2. CAFÉ software 28 13.2.3. Firmware update 28 13.3.
5. Introduction 5. Introduction 5.1. Welcome Thank you for choosing the Lab.gruppen PLM+ Series for your sound reinforcement needs. We are confident that you will be pleased with the performance, unique features, configuration flexibility, reliability, and long-term durability offered by this product. For fast installation and use of this product, your welcome package includes this printed copy of the PLM+ Series Quick Start Guide.
7. Installation 6.2.
7. Installation 7.2. Mounting PLM+ is made for mounting in 19 inch racks. Four screw holes are available for attachment of the amplifier to the racks front rack rail. This device has no top or bottom vents; therefore, units may be stacked directly on top of one another. Sufficient space should be available at the rear to accommodate connectors and cables. In addition, allowance must be made for cable or loom bends within a rack. 7.2.1.
8. Cooling and fan operation 8. Cooling and fan operation PLM+ devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or lids are placed at the front or rear of the rack. Never attempt to reverse the airflow.
9. Operating voltage 9.1. Low voltage country considerations Although the PLM+ Series has a wide range of operating mains voltage, some considerations can be applicable for low voltage regions. PLM+ performs well throughout the specified nominal voltage range but has slightly better efficiency at higher voltages. For regions with nominal voltage below 140 V, one could consider connecting the amplifier in a three-phase delta or two phase split-phase configuration.
10. Grounding 10. Grounding Use correctly-shielded balanced audio input connections to minimize hum and interference. PLM+ Series must be grounded (earthed) with the safety ground pin to the mains distribution system. NEVER disconnect the earth (ground) pin on the mains cable (AC power cord). 11. Product overview 11.1. Front panel Additional information on operations using front panel controls is available in the full PLM+ Series Operation Manual.
11. Product overview Mute Enable – Selection of MUTE ENABLE allows dynamic function buttons to operate as Mute controls for the module inputs and power output channels. The MUTE ENABLE button flashes when the mode is selected; a subsequent press deselects the mode. If left activated, MUTE ENABLE mode will automatically disable two minutes after last mute action. 5 Meter – Successive presses of the METER button scroll through meter views: Amp, Temperature, Input and Module meters, returning to Home.
11. Product overview 11.2. Rear panel 3 1 INPUT 1 SPEAKER OUTPUTS 2 INPUT 2 INPUT 3 INPUT 1-2 INPUT 4 5 INPUT 3-4 1Gbps PRIM 6 ACT 1Gbps SEC LINK ACT LINK 3/0 . 100-240V 2400-2950W 50-60Hz CH 3 BRIDGE BRIDGE CH 1 7 CH 2 CH 4 ANALOG WITH ISO-FLOAT TM PIN 1: SCRN 2: POS 3: NEG SWITCHED 100/1000 Base-TX AES/EBU Made in Sweden CLASS 3 WIRING Ser.
11. Product overview Ethernet and Power Connectors 5 Primary Network Connector – The primary Neutrik RJ45 etherCON® connection provides integration into an Ethernet control network which may include other Lake Processors and the Lake Controller software. Network connection permits full control of all functions along with real-time metering from a remote position. This device supports the Dante audio networking protocol for multichannel, high-definition digital audio over the same Ethernet connection.
12. Signal flow and processing 12. Signal flow and processing The table below depicts the audio signal flow for a PLM+ device.
13. Quick Start Tutorial 13. Quick Start Tutorial This section will describe how to get started with associated software and set up a basic system for operation. 13.1. Network setup 13.1.1. Network connections / topology Each frame has two network ports; a primary and a secondary. See the below diagram for a typical network topology using the primary ports. By default, the secondary ports are configured in dual redundancy mode to support a second redundant network.
13. Quick Start Tutorial 13.2. Software installation and firmware update 13.2.1. Lake Controller software suite 1. The Lake controller software suite includes the Lake controller and accompanying utilities: Lake LoadLibrary and Dante discovery services. Download the Lake Controller installation from www.labgruppen.com. 2. Execute the installer and follow the on-screen instructions. This is a typical software installation where the default settings are acceptable for the vast majority of users. 13.2.2.
13. Quick Start Tutorial 13.3. System setup This tutorial provides a step-by-step guide for configuration of a typical professional loudspeaker system and provides an overview of the basic features and operation of the frame. It describes how to configure 4-channel frame for use with a generic 3-way loudspeaker system (with separate HF, MF and LF drivers), plus a separate subwoofer.
13. Quick Start Tutorial 14. The B module is already a CL1way as default and can be used to drive the sub. 15. Tap Store/Recall EXIT to return to the Modules Menu. 16. Ensuring Module A (or any other module that you want to control) is selected (yellow border), tap I/O Config. 17. The right side of the I/O CONFIG screen displays a block diagram for the Modules.
13. Quick Start Tutorial Levels Control - Drag sliders and tap mute buttons for module input and output channels. Parametric EQ control – Select filter on the top squares and adjust filter properties by dragging the controls. Sliders at the bottom control center frequency and Q (bandwidth). Gain is controlled in the main window area. Additional filters can be added by tapping the top filter objects and placing new filters on the main area.
13. Quick Start Tutorial 21. Repeat step 16 and 20 for the B module. On the Output EQ/Crossover, tap the Aux Output Functions button on the menu bar and then tap LPF Enable button. Drag the Low pass filter control object on the frequency slider just above the menu bar to an appropriate crossover frequency for the sub, e.g. 100 Hz. Output EQ control - Add LPF/HPF and EQ filters and drag to adjust. 22. Use the control options mentioned in 17 to tune your loudspeakers.
13. Quick Start Tutorial Auto RPM: The frame will automatically allocate power per output channel according to the ISVPL settings in the Lake module. If the ISVPL settings taken together allow total output higher than the capabilities of the amplifier, RPM will reduce the ISVPL limiter thresholds evenly based on a proportional reduction in dB. When RPM is active, an RPM icon will be displayed next to the “Actual ISVPL” values in the Events & Control section.
14. Faults and warnings 14.
14. Faults and warnings Category/Type Name On screen text Description Action The Under Voltage limiter is active as the mains supply is approaching the lower end of the device´s operational voltage.
14.
15. Technical Specifications 15. Technical Specifications General Processing / Network Numbers of amplifier channels Total burst power all channels (share among channels with RPM) P L M 5 K4 4 PLM 12 K4 4 P L M 2 0 K4 4 Lake / Dante 4 5000 W 120 0 0 W 20 0 0 0 W Max. Output Power (all ch.’s driven) 1) 2 ohms 2.
15. Technical Specifications Amplifier gain D i g i t a l a t te n u a to r Rear-panel interface A n a l o g i n p u ts AES inputs Output connectors Auto 10 0/10 0 0, Auto Uplink Control and monitoring inter face D et a c h a b l e m a i n s c o rd Cooling P L M 5 K4 4 22 - 44 dB, step size 0.1 dB - Inf to 0 dB, step size 0.
16. Warranty and support 16. Warranty and support 16.1. General This product is manufactured by Lab.gruppen, and it is warranted to be free from any defects caused by components or factory workmanship, under normal use and service, for a period of ten (10) years from date of purchase from an authorized Lab.gruppen dealer. If the product fails to perform as specified during the warranty period, Lab.
16. Warranty and support 16.2.2. Factory service In the event a Lab.gruppen product requires factory service, you may contact Lab.gruppen’s service department for return instructions and a Return Authorization number. Please note for product return: 1. Use the original packing. 2. Include a copy of the sales receipt, your name, return address, phone and fax number, email address and description of the defect. 3. Mark the Return Authorization number on the outside of the packing.
Notes Notes PLM+ SERIES Quick Start Guide rev 3.0.
Notes Notes 42 PLM+ SERIES Quick Start Guide rev 3.0.
Lab.gruppen adopts a policy of continuous improvement and product specification is subject to change. RPM, R.SMPS, PFC, CDM, BEL, UVL, CAFÉ, ESP, ISVPL, Iso-Float, Raised Cosine, MESA EQ, LimiterMax and LoadLibrary are trademarks of Lab.gruppen AB. All other trademarks remain the property of their respective owners. Copyright © 2017 MUSIC Group Innovation Sweden AB. All rights reserved. Item no. QSG-PLM+SERIES labgruppen.