Current Draw & Thermal Dissipation

LUCIA® 240/2M
Item no. CDTD-LUCIA2402M - 03.12.2015
Current Draw and Thermal Dissipation
LUCIA: Localized Utility Compact Intelligent Amplification
W WW.LABGRUPPEN.COM
The following tables contain information on measured current consumption as well as calculated heat dissipation during what we see as
the most extreme sustained normal operation (1/8 rated power).
LUCIA 240/2M
Level Load Output power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC In Out Dissipated BTU/hr kCal/hr
Standby w. remote Power Off.
230 0.032 0.88 0 1 3 1
120 0.027 0.77 0 1 3 1
100 0.028 0.76 0 1 3 1
Power on, Idling
230 0.14 14.8 0 15 51 13
120 0.21 13.4 0 13 46 12
100 0.25 14.1 0 14 48 12
Pink Pseudo
Noise (1/8)
16 Ω / Ch. 60 x 2
230 0.31 37. 3 15 22 76 19
120 0.48 35.1 15 20 69 17
100 0.60 35.1 15 20 69 17
8 Ω / Ch. 120 x 2
230 0.45 56.6 30 27 91 23
120 0.71 54.6 30 25 84 21
100 0.83 55.6 30 26 87 22
4 Ω / Ch. 120 x 2
230 0.47 5 8.1 30 28 96 24
120 0.75 57.1 30 27 92 23
100 0.86 57. 8 30 28 95 24
2 Ω / Ch. 120 x 2
230 0.49 62.0 30 32 109 28
120 0.77 59.3 30 29 100 25
100 0.93 62.1 30 32 110 28
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.