80905_Rev. 1.
Contents 1. What is IPAS? 3 2. Caution / Warning for Safety 4 3. Components / Names of Parts 5 4. Specifications 6 5. Installation 7 6. Setting 8 ~ 10 · [IND] Danger / Caution Area Distance Setting 8 · [IND] Volume Control 8 · [IND] Setting Initialization 8 · [IND] How to Set the Distance 9 · [PT] Alarm type Setting 10 · [PT] Volume Control 10 7.
1. What is IPAS? KIGIS IPAS is an intelligent proximity alert safety and assistant system that prevents collisions by signaling dangers in 2 way communication to both drivers and pedestrians when pedestrians approach to a vehicle or vehicles approach to other vehicles in industrial working site. It is easy to install without causing any damages to the vehicle, and compared to other products, the outstanding proximity detection is an advantage that KIGIS IPAS only offers. "Watch Out.
2. Caution/Warning for Safety Caution! ※ Failure to observe the precautions in this manual may result in damage to the product or your property. DC 12/24V Use only DC 12/24V. For vehicles with DC 36/48V, be sure to connect SMPS module to use DC 12/24V. Otherwise, this may cause trouble. Do not place the product near flammable materials, stoves, candles, or fire. This may cause fire and product deformation. Do not intentionally immerse the product in water or wash it in running water.
3. Components/Names of Parts Components Vehicle Tag(VT) Indicator Pedestrian Tag(PT) Helmet Holder High Speed Charging Cable(PT) User Manual Fuse Cable Harness(6m) Open Wire Adapter Cable ※ Tag may not be recharged with general charging cable. ※ It is strongly recommended that the tag should be installed on epaulet or arm band due to communication problem in case of installation at waist or in pocket.
4. Specifications Specifications Vehicle Tag(VT) Indicator Pedestrian Tag(PT) Product Image Power Electrical Feature 12/24V DC Input(9/32Vdc) 12/24V DC Input(9/32Vdc) - Current 300mA 500mA - Interface CAN Bus 2.0 CAN Bus 2.
5. Installation Caution! It is highly recommended to install IPAS with the power off. Turn on the power after connecting all products. Vehicle Tag(VT) Cable Harness(6m) or Open Wire Adapter Cable 5m or 3m Indicator Cigar Jack Adapter * Normal operation : Green Flash ON after turning on the power. * Caution! Wind up cable terminals to properly connect them. Disregarding this caution, it may cause a malfunction caused by liquid matters.
6. Setting - Indicator Danger / Caution Area Distance Setting ※ I n a condition of normal operation ① Press and hold SET 1 and SET 2 buttons simultaneously for 2 seconds or more. ② Set the desired Danger Area distance by operating the SET 1 and SET 2 buttons. (Refer to "How to set the distance" on the following page) ③ Press STOP to complete the Danger Area setting. ④ When the green LED is on, set the distance to the Caution Area.
6. Setting - Indicator How to Set the Distance Distance setting can be set to even distance [2 / 4 / 6 / 8 / 10m] or odd distance [1 / 3 / 5 / 7 / 9m]. The default setting is even distance. SET 1 button : Distance -2 m STOP button : OK SET 2 button : Distance + 2m 2m space per LED lamp [ ON OFF ] : 2m or 1m : 4m or 3m : 6m or 5m : 8m or 7m : 10m or 9m * Odd distance [1 / 3 / 5 / 7 / 9m] change : Press and hold SET 1 button + STOP button at the same time.
6. Setting - Pedestrian Tags Alarm type Setting ① Press and hold the power button to turn on the power. (Charging is required if the red LED is on.) Press Power button 1 time > Sound Press Power button 1 more time > Vibration ④ Press and hold the menu button to complete the setup. Press Power button 1 more time > Sound + Vibration > (Sound + Vibration) ③P ress the power button to set the desired alarm type. ( Please refer to the alarm system below.
7. How to use Indicator Instruction that a driver must know Situation LED Lamp Status When a pedestrian(PT) trespass on the Caution Area When a pedestrian(PT) trespass on the Danger Area Alarm Mute Alarm Repeating "Watch Out" Red / Green Light flashes gradually Repeating "Danger" Press STOP Button 1 Time Even though alarm ismuted (double clikc), in case that pedestrian escapes the set Danger / Caution Area and reenters them, the alarm will go off again.
7.
8. Check list before reporting failure Question Reason Solution You can access the menu after turning on the power. If you press and hold the power button for 2 seconds, the green LED will blink. Press and hold the menu button for 2 seconds afterward. There is a red It is a signal indicating low voltage when the remaining battery power is less than 4 LED on the PT. hours. Please charge it. When it is 100% charged, the green LED will turn on.
ME MO
WARRANTY Warranty Term 1 year from the purchase date Product Name Model Name Place of Purchase Date of Purchase Name of Customer Phone Number * Service information 1. If a performance or functional failure occurs while proper using during the warranty period, the repair service is free of charge. 2. When the repair service is required, please present the warranty card with all information filled in. 3. The following cases will be charged for the repair regardless of warranty period.
T h in k Sm a rt , Work Safe Distributor(or purchasing store) Manufacturer * Any inquiry about the purchased product is contactable to distributor(or purchasing store) at below line. KYUNGWOO SYSTECH, INC. 4F, Daeryung Post Tower 5, 68, Digital-ro 9-gil, Geumcheon-gu, Seoul, 08512, Republic of Korea Tel. +82-2-985-8085 Fax. +82-2-985-8087 E mail. info@kigistec.com www.kyungwoo.com / www.kigistec.