KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD HDO Fixture User Manual UPDATE: 14 Aug.2020 VERSION:V1.0.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD TABLE OF CONTENTS 1. LEGAL NOTICES .....................................................................................................................................4 2. WARRANTY .............................................................................................................................................5 3. SECURITY SUMMARY ............................................................................................................................
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 10.1 START-UP AND STANDBY INTERFACE ..................................................................................................26 10.2 HEATING INTERFACE ...........................................................................................................................26 10.3 KEEP WARM INTERFACE .....................................................................................................................27 10.4 COMPLETION INTERFACE ..............
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 1. LEGAL NOTICES The information in this document is subjected to change without notice. Kunshan Myzy Fixture Technology Co., Ltd. makes no warranty for any kind with regard to this manual, including, but no limited to the implies of warranties of merchantability and fitness for a particular purpose. Kunshan Myzy Fixture Technology Co., Ltd.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 2. WARRANTY All Myzy fixtures are warranted against defects in material and workmanship for a period of one year after date of shipment. Myzy agrees to repair or replace any assembly or component found to be defective, under normal use during this period.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 3. SECURITY SUMMARY The following general safety precautions must be observed at all stages of operation, service, and maintenance testing fixtures. Failure to comply with these precautions or the use of specific warnings given elsewhere in this manual will violate safety standards for the design, manufacture, and testing of fixtures. If the customer fails to comply with these requirements, Myzy will not be held responsible.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD STORAGE When the tester is no longer in use, please pack it properly and store it in a good environment. 1 Indoor Temperature 23℃±3 ℃ 2 Indoor Humidity 45%~60% 3 Places that do not receive direct sunlight 4 Keep away from water and oil stains 5 Keep away from areas containing volatile components or corrosive gases 6 Store in a dust-free place as much as possible. 7 Avoid subjecting the fixture to vibration shocks above 0.5G.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 4. REVISION HISTORY Date Version Change Note 14.08.2020 v1.0.0 Complete this manual 20.08.2020 v1.0.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 5. INTRODUCTION 5.1 Function This is a manual disassembling HDO Fixture, Model: MZ20-FT012-01. The fixture is mainly composed of HDO Main Fixture, Main Box and specific Hot Pockets. It is an automatic heating controlled and manual disassembly of the phone display for defective products, and achieve fast and high yield rate of product repair and dismantling. 5.2 Main Purpose This fixture is automatically heat controlled universal display opener for iPhone. 5.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 5.5 Fixture Overview 5.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 5.7 HDO (Heat Display Opener) 5.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 5.9 Suction Cup Assembly 5.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 5.11 Toggle CAM 5.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 6. ILLUSTRATION OF FIXTURE PARTS 6.1 Main Fixture 6.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 6.3 HDO Key Module 6.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 6.5 North Bar Module 6.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 6.7 Main Box 6.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 7. SAFETY REGULATIONS • The fixture to be operate by one person, the operator and all users must be trained qualified to used the fixture. • Before start up, please ensure all the power cables are proper connection. • Operators cannot leave the workplace at will. • During operation process, if encountered the fixture abnormality, please press the Emergency Stop Switch. • Do not simply change the relevant parameters of the fixture.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 7.1 Warning Signs Description Do not touch hazardous power sources. Do not put your fingers into the HDO fixture while it is operating. Beware with the hot copper bar.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 7.2 Safety Device When the temperature is abnormal, you can press the emergency stop switch, the device will immediately cut off the entire fixture power.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 8.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 9. OPERATION PROCEDURES STEP1. PRE-START PREPARATION(FIXTURE + HOT POCKETS + DUT) STEP2.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD STEP3. FIXING OF MOBILE PHONE STEP4.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD STEP5. SUCTION CUP PRESSES DOWN STEP6.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD STEP7. TAKEOUT THE HOT POCKET STEP8.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 10. SOFTWARE INTERFACE AND ERROR CODES 10.1 Start-up and Standby Interface After powering on the unit, the unit self-tests with no abnormalities, then the North Bar begins to warm up to 50 degrees and the LCD displays as shown below. 10.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 10.3 Keep warm interface When the North Bar and Hot Pocket heat up to a steady state, the timer starts counting down. ( Note: Do not turn the knob at this time, otherwise an E01 error will be reported ) 10.4 Completion Interface When the countdown is over the buzzer will be activated, indicating that the operator can release the knob to start the disassembly screen. The fixture will display a 15mins countdown to remind the operator to take out the hot pocket.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 10.5 ERROR CODE AND TROUBLE SHOOTINGS ERR.Code Description Solution E01 Turn the knob during the heating process Restart the fixture and follow the procedure. E02 Hot Pocket has not removed the within 15min. Restart the fixture and follow the procedure.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 11. MAINTENANCE Note: Turn off the power before perform maintenance and do not operate until the heating bar temperature drops below 35°C. PURPOSE The test fixture is performed by a precise mechanical movement, which must be regularly maintained in order to guarantee the normal use of the fixture. Items Method Daily Monthly Clean the hot pocket and HP Track before power on. Lint-free cloths Ensure the emergency stop switch is functioning well.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 12. CONSUMABLE PART LIST No. Part No.
KUNSHAN MYZY FIXTURE TECHNOLOGY CO.,LTD 13. SPARE PART LIST No. Part No. Description Brand Safety inventory 1 0105-99-032995 RFID Antenna Myzy 1pc / Site 2 0105-17-032956 Power supply MeanWell 1pc / Site 3 0305-14-010871 PCB Board Myzy 1set / Site 4 0105-07-032963 LCD Screen TaoJingChi 1pc / Site 5 0105-27-008856 Buzzer Myzy 1pc / Site Remark N/A 14.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.