Product Card

This document is not contractual - Kohler Co. reserves
the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.
GBD5-05004 (KH440) 03/17
KH440
Engine type
P158LE
Alternator type KH01483T
Performance class
G3
GENERAL CHARACTERISTICS
Frequency (Hz)
Voltage (V)
Standard control panel
POWER
ESP PRP
Voltage
kWe kVA kWe kVA
Standby Amps
DIMENSIONS COMPACT VERSION
Length (mm) 3470
Width (mm) 1500
Height (mm) 1829
Dry weight (kg) 2942
Tank capacity (L) 500
DIMENSIONS SOUNDPROOFED VERSION
Commercial reference of the enclosure M229
Length (mm) 5031
Width (mm) 1560
Height (mm) 2435
Dry weight (kg) 4125
Tank capacity (L) 500
Acoustic pressure level @1m in dB(A) 85
Sound power level guaranteed (Lwa) 105
DESCRIPTIVE
Kohler Co. Provides one-source responsibility for the
generating system and accessories
A one-year limited warranty covers all systems and
components
Mechanically welded chassis with antivibration
suspension
Main line circuit breaker
POWER DEFINITION
PRP : Prime Power is available for an unlimited number of annual
operating hours in variable load applications, in accordance with ISO
8528-1. ESP : The standby power rating is applicable for supplying
emergency power in variable load applications in accordance with ISO
8528-1. Overload is not allowed
TERMS OF USE
According to the standard, the nominal power assigned by the genset is
given for 25°C Air Intlet Temperature, of a barometric pressure of 100
kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions
in your installation, refer to the derating table.
ASSOCIATED UNCERTAINTY
For the generator sets used indoor, where the acoustic pressure levels
depend on the installation conditions, it is not possible to specify the
ambient noise level in the operating and maintenance instructions.
You will also find in our operating and maintenance instructions a
warning concerning the air noise dangers and the need to implement
appropriate preventive measures.
Radiator for core temperature of 48/50°C max with
mechanical fan
Protective grille for fan and rotating parts (CE option)
9 dB(A) silencer supplied separately
Charger DC starting battery with electrolyte
24 V charge alternator and starter
Optional control panel
Optional control panel
50
400/230
DEC4000
APM802
M80
Acoustic pressure level @7m in dB(A) 75
415/240 350
437
318
397
608
400/230 350
437
318
397
631
380/220 350
437
318
397
664
Delivered with oil and coolant -30°C
Manual for use and installation
The generator set and its components are prototype-
tested, factory-built, and production-tested
Electronic governor