Specification
Features
•
Brass construction
•
Fixture-mount design
•
Intended for urinal installations with 3/4″ spud
coupling connection
•
Non-hold open piston technology for accurate
activation
•
Retrofit models require a control stop and vacuum
breaker
•
1.0 gpf (3.8 lpf) flow rate [K-13518 and K-13518-RF]
•
0.5 gpf (1.9 lpf) flow rate [K-13519 and K-13519-RF]
Codes/Standards Applicable
Specified model meets or exceeds the following:
•
ADA
•
ASSE 1037
•
CSA B125.3
•
ICC/ANSI A117.1
•
CSA B64
•
CSA B651
•
OBC
EXPOSED FLUSHOMETER
K-13518
ALSO K-13518-RF, K-13519,
K-13519-RF
OBC
ADA CSA B651
Colors/Finishes
•
CP: Polished Chrome
Specified Model
Model Description Colors/Finishes
K-13518 Exposed flushometer - 1.0 gpf (3.8 lpf), washout ❑ CP
K-13518-RF Exposed flushometer (retrofit) - 1.0 gpf (3.8 lpf), washout ❑ CP
K-13519 Exposed flushometer - 0.5 gpf (1.9 lpf), washout ❑ CP
K-13519-RF Exposed flushometer (retrofit) - 0.5 gpf (1.9 lpf), washout ❑ CP
Product Specification
The exposed manual flushometer shall be made of brass construction. Flushometer shall feature non-hold open piston
technology for accurate activation. Flushometer shall have a fixture-mount design. Flushometer is intended for urinal
installations with a 3/4″ spud coupling connection, and retrofit models require a control stop and vacuum breaker. Flushometer
shall have a 1.0 gpf (3.8 lpf) flow rate [K-13518 and K-13518-RF] or 0.5 gpf (1.9 lpf) flow rate [K-13519 and K-13519-RF].
Exposed manual flushometer shall be Kohler Model K-_____-CP.
Page 1 of 2
1151510-4-
C
USA/Canada: 1-800-4KOHLER
(1-800-456-4537)