D High Quality Power
Kohler home generators provide advanced voltage and
frequency regulation along with ultra-low levels of harmonic
distortion for excellent generator power quality to protect your
valuable electronics.
D Premium 5-yr/2000-hr Limited Warranty Included
Kohler is known for extraordinary reliability and performance.
Kohler’s premium limited warranty covers parts, labor, and
travel for the full warranty period.
D Powerful Performance
Exclusive Powerboostt technology provides excellent
starting power.
w
D Aluminum Enclosure
d Attractive aluminum enclosure allows installation as close
as 18 inches from your home or small business.
[
d Enclosure panels can be removed without tools to allow
easy access for maintenance and service.
D Camouflage Enclosures are available for single-phase units
(optional). Go to KohlerGenerators.com/MossyOak to view
the available patterns.
Mossy Oak is a trademark used under license from Haas Outdoors, Inc., by Kohler Co.
Standard Features
D RDC2 Controller
d One digital controller manages both the generator set and
transfer switch functions (with optional Model RXT).
d Electronic speed control responds quickly to varying
demand.
d OnCuer Plus Generator Management System for remote
monitoring is included with the generator.
D Kohler Command PRO Engine Features
d Kohler Command PROr OHV engine with hydraulic valve
lifters for reliable performance without routine valve
adjustment or lengthy break-in requirements.
D Designed for Easy Installation
d Sturdy aluminum base can be mounted on gravel or a
concrete mounting pad.
d Fuel and electrical connections through the enclosure wall
eliminate the need for stub-ups through the base.
d Customer connection terminal block located near the
controller allows easy access for field wiring.
d Designed for outdoor installation only.
d Approved for stationary standby applications in locations
served by a reliable utility source (on-grid).
D Certifications
d Meets emission regulations for U.S. Environmental
Protection Agency (EPA) with both natural gas and LPG.
d UL 2200/cUL listed.
d Accepted by the Massachusetts Board of Registration of
Plumbers and Gas Fitters.
d Meets 181 mph wind rating.
D Exercise Modes
d 90-second EcoExercise, unloaded, with system
diagnostics. Reduces fuel costs and minimizes sound
disruption.
d Unloaded weekly exercise with complete system
diagnostics (20 minutes)
d Unloaded full-speed exercise (20 minutes)
d Loaded full-speed exercise (20 minutes; Model RXT ATS
required)
d W eekly, bi- weekly, or new monthly exercise intervals.
D Model 26RCAL includes a model RXT automatic transfer
switch. See last page for more details.
Generator Ratings
Standby Ratings
Line Circuit
Breaker
Natural Gas LPG
Model Alt Voltage Ph Hz kW/kVA Amps kW/kVA Amps Amps Poles
26RCA
26RCAL
2F8 120/240 1 60 24/24 100 26/26 109 125 2
26RCA 2G8
120/208 3 60 22/27 77 22/27 77 80 3
120/240 3 60 22/27 67 22/27 67 80 3
277/480 3 60 22/27 34 22/27 34 40 3
Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration.
RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average
load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO- 3046/1, BS5514, AS2789, and DIN 6271. GENERAL
GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 2% per 5.5_C(10_F) temperature increase above 16_C(60_F).
Availability is subject to change without notice. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.
Contact your local Kohler Co. generator dealer for availability.
w Check the appliance manufacturer’s specifications for actual power requirements. Consult a Kohlerr Power Systems professional to calculate your exact residential power system requirements.
[ Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure.

Summary of content (4 pages)