Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 1 / 13 Written by Checked by Approved by Dongle PL Test Manual 결 작 성 검 토 승 인 / / / 재 2016. 11. 21. KN-연-062 (13.10.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 2 / 13 Written by Checked by Approved by Document Revision History No 1 Description -. initial KN-연-062 (13.10.18)-0 Author BJ KIM Page REV. NO 1.0 Revised Date 2016.11.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 3 / 13 Written by Checked by Approved by INDEX DOCUMENT REVISION HISTORY ........................................................................................................................ 2 1. DONGLE-PL TEST USING THE POWER SUPPLY .................................................................................... 4 2.
Document NO. Project Code Project Name Subject 1. KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 4 / 13 Written by Checked by Approved by Dongle-PL Test using the Power Supply 1-1. Dongle-PL Test using the Power Supply - Dongle PL Board is powered by a Power Supply. current consumption check using the Power Supply - Power Supply settings DC15V, 1A - Dongle-PLs average power consumption is under 0.3W.
Document NO. Project Code Project Name Subject 1-6. KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 5 / 13 Written by Checked by Approved by Open the RF Test Program to download to Dongle PL. MG245X-KMW_IQVIEWER_V22_PA_Rev02.H00 MG245X-KMW_IQVIEWER_V22_PA_Rev02.H01 - 1-7. Download only choose H00 file extension. Download to LCS Node. < Download complete message > 1-8. Change into Operating Mode 2. IQ NxN Test Setting 2-1.
KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Document NO. Project Code Project Name Subject Revision NO. P1.0 Revised Date 2016.11.21 Page 6 / 13 Written by Checked by Approved by < PC’s IP > 2-3. Execute IQsignal for Zigbee. And Setting Parameter as under figure. < IQsignal for Zigbee Program Parameter Setting > 2-4. 3. Connect USB to Serial Cable to Z_Deg port(J2). TX Test 3-1. Connect IQ NXN's RF1 channel to RF output(MCX) using the RF Cable.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 7 / 13 Written by Checked by Approved by < Tera Term’s Serial Port setting > - Press 'H' key on the keyboard to display the test menu as below.. < KMW TEST MENU > - Press 'C' key on the keyboard and select channel. < For example selected 11 channel.> - if press 'M' on the keyboard, Tx will be sent Modulation with IFS. KN-연-062 (13.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 8 / 13 Written by Checked by Approved by 3-2. Implement Tx test using the IQsignal for Zigbee Program. - Measure Antenna: HW-2450D-MSMA2 HANWOOL TECH ( SEGA Antenna ) -Trigger type : signal trigger -.Triger level : -25dBm - External Atten : 10dBm < Dongle-PL Position (Use SEGA Antenna) > KN-연-062 (13.10.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Page Revised Date 2016.11.21 9 / 13 Written by Checked by Approved by < Tx test measure > - Compare with the following items to check for defects Req'd Spec Remark Transmit Power ≥3dBm [6.9.5]IEEE802.15.4-2006 Spectrum PSD mask 확인 Transmit Center Frequency Tolerance ±40ppm [6.9.4]IEEE802.15.4-2006 Error Vector Magnitude ≤35% [6.9.3]IEEE802.15.4-2006 [6.5.3.
Document NO. Project Code Project Name Subject - KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 10 / 13 Written by Checked by Approved by RX Test 4-1. Execute 'vector signal analyzer' as under figure. 4-2. Connect IQnxn's RF2 Channel to device's output. 4-3. Open the 'zigbee_psdu20.mod' file. 4-4. Execute ‘Tera Term’ And then Setting port. ( 3-2.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 11 / 13 Written by Checked by Approved by 4-6. If press '2' on the keyboard, can be check transmitted result. < Tera Term Rx count Output Screen > - Compare with the following items to check for defects Req'd Spec Receiver Sensitivity ≥-75dBm Remark [6.5.3.3]IEEE802.15.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 12 / 13 Written by Checked by Approved by FCC compliance Information FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 13 / 13 Written by Checked by Approved by This device is intended only for OEM integrators under the following conditions: 1)The transmitter module may not be co-located with any other transmitter or antenna, 2)OEM shall not supply any tool or info to the end-user regarding to Regulatory Domain change.