INSTALLATION INSTRUCTIONS IN-LINE SMART KIT Installation Instructions For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca INSTRUCTIONS D’INSTALLATION VENTILATEUR DÉPORTÉ INTELLIGENT Instructions d’installation Au Canada, pour assistance, installation ou service, composer le 1-800-807-6777 ou visiter notre site Web à www.whirlpool.
TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY .................................................................2 INSTALLATION REQUIREMENTS ................................................4 Tools and Parts ............................................................................4 Location Requirements................................................................4 Venting Requirements..................................................................5 Electrical Requirements ...................
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. ■ Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
INSTALLATION REQUIREMENTS ■ 1 - T10 Torx®† adapter Tools and Parts ■ 1 - T20® Torx® adapter Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. ■ 1 - Plastic wire clip ■ 4 - 5 x 45 mm mounting screws ■ 3 - 2.
Venting Requirements ■ Vent system must terminate to the outdoors. ■ Do not terminate the vent system in an attic or other enclosed area. ■ Do not use 4" (10.2 cm) laundry-type wall caps. ■ Use round, metal venting only. Rigid metal venting is recommended. Plastic or metal foil venting is not recommended. ■ The length of the vent system and the number of elbows should be kept to a minimum to provide efficient performance.
Electrical Requirements Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Install In-Line Smart Kit KVWB40DS Series Range Hoods Remove Blower Motor from Range Hood Housing 4. Using the T10 Torx® adapter, remove the 4 screws from the blower motor cover plate. Remove the cover plate from the motor and set it aside. WARNING C Electrical Shock Hazard B Disconnect power before servicing. A Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power. A. Blower motor cover plate B. Screws (4) C.
7. Push on the blower motor to disengage the two spring tabs from the keyhole slots in the top of the range hood housing. 3. Install the vent transition without a backdraft damper to the bottom of the in-line base. Use the T10 Torx® adapter and install 2 - 3.5 x 9.5 mm mounting screws to secure the transition to the base. A B C A A. Keyhole slots 8. Remove the blower motor from the range hood housing and set it aside. 9. Reinstall the 2 insulation retainers and 2 screws to the range hood housing.
8. Connect the 9-pin connector from the blower motor to the 9-pin connector inside the in-line base. Install In-Line Smart Kit The In-Line Smart Kit must be installed to a secure structure of the roof, ceiling, wall, or floor. The In-Line Smart Kit may also be installed into a new or existing frame construction. WARNING Excessive Weight Hazard 9. Slide the in-line housing inside the in-line base. Align the mounting holes in the in-line housing to the mounting holes in the in-line base.
Complete Installation Determine and make all necessary cuts and drill holes for the vent system. IMPORTANT: When cutting or drilling into the ceiling or wall, be sure to not damage electrical wiring or other hidden utilities. 1. Install the range hood in its final location. Use the Installation Instructions provided with the range hood. 2. Determine the location where the ¹⁄₂" (13 mm) wiring conduit will be routed through the ceiling or wall to connect the InLine Smart Kit and the range hood. 3.
Make Electrical Connection WARNING Connect Range Hood and In-Line Smart Kit 1. Measure the distance between the In-Line Smart Kit and the range hood terminal box. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. A Failure to do so can result in death or electrical shock. Connect Range Hood 1. Connect the 9-pin pigtail electrical connector provided with the In-Line Smart Kit to the 9-pin electrical connector inside the range hood. E A.
Electrical Connection Range Hood Connect In-Line Smart Kit Electrical Connection In-Line Smart Kit 1. Use a UL listed or CSA approved wire connector to connect the black wires together. 2. Use a UL listed or CSA approved wire connector to connect the white wires together. 3. Use a UL listed or CSA approved wire connector to connect the red wires together. 4. Use a UL listed or CSA approved wire connector to connect the blue wires together. 5.
4. Using the T10 Torx® adapter, remove the 4 screws from the blower motor cover plate. Remove the cover plate from the motor and set it aside. 7. Push on the blower motor to disengage the 2 spring tabs from the keyhole slots in the top of the range hood housing. C A A A. Keyhole slots B A. Blower motor cover plate B. Screws (4) C. Range hood 5. Disconnect the blower motor from the range hood wiring. Press the top and bottom clip of the 9-pin electrical connector to disconnect. 8.
11. Install the metal terminal box supplied with the In-Line Smart Kit to the top of the range hood using 2 - 3.5 x 6.5 mm mounting screws. 3. Install the vent transition without a backdraft damper to the bottom of the in-line base. Use the T10 Torx® adapter and install 2 - 3.5 x 9.5 mm mounting screws to secure the transition to the base. A B C A. In-line base B. Vent transition (without backdraft damper) C. 3.5 x 9.5 mm screws (2) 12. Reinstall the blower motor cover plate and bottom panel.
8. Connect the 9-pin connector from the blower motor to the 9-pin connector inside the in-line base. Install In-Line Smart Kit The In-Line Smart Kit must be installed to a secure structure of the roof, ceiling, wall, or floor. The In-Line Smart Kit may also be installed into a new or existing frame construction. WARNING Excessive Weight Hazard 9. Slide the in-line housing inside the in-line base. Align the mounting holes in the in-line housing to the mounting holes in the in-line base.
Complete Installation Determine and make all necessary cuts and drill holes for the vent system. IMPORTANT: When cutting or drilling into the ceiling or wall, be sure to not damage electrical wiring or other hidden utilities. 1. Install the range hood in its final location. Use the Installation Instructions provided with the range hood. 2. Determine the location where the ¹⁄₂" (13 mm) wiring conduit will be routed through the ceiling or wall to connect the InLine Smart Kit and the range hood. 3.
Make Electrical Connection WARNING 4. Connect together the set of 8 wires in the range hood terminal box. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. Connect Range Hood and In-Line Smart Kit Connect In-Line Smart Kit 1. Measure the distance between the In-Line Smart Kit and the range hood terminal box. A A. Distance between in-line smart kit and the range hood terminal box 2.
Install In-Line Smart Kit JXW85DS, JXI85DS, KVWB60DS, and KVIB60DS Series Range Hoods Remove Blower Motor from Range Hood Housing WARNING 4. Using the T10 Torx® adapter remove the screws securing the filter retainer panel to the range hood. See the following illustrations for screw locations and numbers. JXW85DS and JXI85DS Range Hoods A Electrical Shock Hazard B Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
5. Disconnect the blower motor from the range hood wiring. Using a flat blade screwdriver, and press down on the top clip of the 9-pin electrical connector while pressing the bottom clip. Unplug the blower motor from the 9-pin connector. 8. Using the T20® Torx® adapter with a long extension, remove the 4 screws that secure the blower motor to the range hood housing and set them aside. A 6. Using the T10 Torx® adapter, remove the screw that secures the temperature sensor to the bottom rear panel. B C A.
14. Remove the 2 electrical knockouts from the top of the range hood electrical box and install a UL listed or CSA approved plastic strain relief into the front knockout. 15. Remove the 9-pin connector inside the range hood electrical box. Insert a flat-blade screwdriver into the lateral clips while removing the connector (see the following illustration). 16. Cut the wire tie that is closest to the 9-pin electrical connector. A 18.
22. Install the metal terminal box suppled with the In-Line Smart Kit to the top of the range hood electrical box. Use 2 - 3.5 x 6.5 mm screws to secure the terminal box. A 3. Install the vent transition without a backdraft damper to the bottom of the in-line base. Use the T10 Torx® adapter and install 2 - 3.5 x 9.5 mm mounting screws to secure the transition to the base. B A B C C A. In-line base B. Vent transition (without backdraft damper) C. 3.5 x 9.5 mm screws (2) A. 3.5 x 6.5 mm screws (2) B.
8. Connect the 9-pin connector from the blower motor to the 9-pin connector inside the in-line base. Install In-Line Smart Kit The In-Line Smart Kit must be installed to a secure structure of the roof, ceiling, wall, or floor. The In-Line Smart Kit may also be installed into a new or existing frame construction. WARNING Excessive Weight Hazard 9. Slide the in-line housing inside the in-line base. Align the mounting holes in the in-line housing to the mounting holes in the in-line base.
Complete Installation Determine and make all necessary cuts and drill holes for the vent system. IMPORTANT: When cutting or drilling into the ceiling or wall, be sure to not damage electrical wiring or other hidden utilities. 1. Install the range hood in its final location. Use the Installation Instructions provided with the range hood. 2. Determine the location where the ¹⁄₂" (13 mm) wiring conduit will be routed through the ceiling or wall to connect the InLine Smart Kit and the range hood. 3.
Make Electrical Connection WARNING 5. Connect together the set of 8 wires in the range hood terminal box. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. Connect Range Hood and In-Line Smart Kit Connect In-Line Smart Kit 1. Install the UL listed or CSA approved strain reliefs (3) in the range hood and In-Line Smart Kit electrical knockouts. 2.
Install In-Line Smart Kit WVW75UC and WV175UC Series Range Hoods Remove Blower Motor from Range Hood Housing WARNING 5. Remove the 2 screws securing the insulating retainer to the blower motor and set them aside. 6. Disconnect the blower motor from the range hood wiring. Using a flat blade screwdriver, and press down on the top clip of the 9-pin electrical connector while pressing the bottom clip. Unplug the blower motor from the 9-pin connector. Electrical Shock Hazard Disconnect power before servicing.
9. Remove the 2 electrical knockouts from the top of the range hood electrical box and install a UL listed or CSA approved plastic strain relief into the front knockout. 10. Remove the 9-pin connector inside the range hood electrical box. Insert a flat-blade screwdriver into the lateral clips while removing the connector (see the following illustration). 11. Cut the wire tie that is closest to the 9-pin electrical connector. A 13.
17. Install the metal terminal box suppled with the In-Line Smart Kit to the top of the range hood electrical box. Use 2 - 3.5 x 6.5 mm screws to secure the terminal box. A 3. Install the vent transition without a backdraft damper to the bottom of the in-line base. Use the T10 Torx® adapter and install 2 - 3.5 x 9.5 mm mounting screws to secure the transition to the base. B A B C C A. In-line base B. Vent transition (without backdraft damper) C. 3.5 x 9.5 mm screws (2) A. 3.5 x 6.5 mm screws (2) B.
8. Connect the 9-pin connector from the blower motor to the 9-pin connector inside the in-line base. Install In-Line Smart Kit The In-Line Smart Kit must be installed to a secure structure of the roof, ceiling, wall, or floor. The In-Line Smart Kit may also be installed into a new or existing frame construction. WARNING Excessive Weight Hazard 9. Slide the in-line housing inside the in-line base. Align the mounting holes in the in-line housing to the mounting holes in the in-line base.
Complete Installation Determine and make all necessary cuts and drill holes for the vent system. IMPORTANT: When cutting or drilling into the ceiling or wall, be sure to not damage electrical wiring or other hidden utilities. 1. Install the range hood in its final location. Use the Installation Instructions provided with the range hood. 2. Determine the location where the ¹⁄₂" (13 mm) wiring conduit will be routed through the ceiling or wall to connect the InLine Smart Kit and the range hood. 3.
Make Electrical Connection WARNING 5. Connect together the set of 8 wires in the range hood terminal box. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. Connect Range Hood and In-Line Smart Kit Connect In-Line Smart Kit 1. Install the UL listed or CSA approved strain reliefs (3) in the range hood and In-Line Smart Kit electrical knockouts. 2.
WIRING DIAGRAM 1 BU GY BK RD M WH YL BR 3 4 5 6 7 8 9 BU GY BK RD WH YL BR YL/GN YL/GN YL/GN 2 SE14CA 31
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres.
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS SUIVANTES : ■ Utiliser cet appareil uniquement dans les applications envisagées par le fabricant. Pour toute question, contacter le fabricant.
EXIGENCES D’INSTALLATION Outillage et pièces Rassembler les outils et pièces nécessaires avant d’entreprendre l’installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous.
Exigences concernant l’évacuation ■ Le système doit évacuer l’air à l’extérieur. ■ Ne pas terminer le circuit d’évacuation dans un grenier ou dans un autre espace clos. ■ Ne pas utiliser une bouche de décharge murale de 4" (10,2 cm) normalement utilisée pour un équipement de buanderie. ■ Utiliser un conduit métallique cylindrique uniquement. Un conduit d’évacuation en métal rigide est recommandé. Ne pas utiliser de conduit de plastique ou métallique souple extensible.
Spécifications électriques Observer les dispositions de tous les codes et règlements en vigueur. S’assurer que l’installation électrique est correcte et qu’elle satisfait aux exigences de la plus récente édition de la norme National Electrical Code, ANSI/NFPA 70, ou de la norme CSA C22. 1-94, Code canadien de l’électricité, partie 1 et C22.2 No 0M91 (dernière édition) et de tous les codes et règlements en vigueur.
Installation du ventilateur déporté intelligent Hottes série KVWB40DS Dépose du moteur du ventilateur de la caisse de la hotte 4. À l’aide de l’adaptateur Torx® T10, ôter les 4 vis du couvercle du moteur du ventilateur. Retirer le couvercle du moteur et le mettre de côté. AVERTISSEMENT C Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche.
7. Pousser le moteur du ventilateur pour dégager les deux languettes à ressort des orifices en trou de serrure situés en haut de la caisse de la hotte. 3. Installer le raccord de transition sans clapet anti-reflux du côté inférieur de la base du ventilateur déporté. À l’aide de l’adaptateur Torx® T10, poser 2 vis de 3,5 x 9,5 mm pour fixer le raccord de transition à la base. A B C A. Base du ventilateur déporté B. Raccord de transition (sans clapet anti-reflux) C. Vis de 3,5 x 9,5 mm (2) A A.
8. Brancher le connecteur à 9 broches du moteur du ventilateur à son homologue à l’intérieur de la base du ventilateur déporté. Installation du ventilateur déporté intelligent Le ventilateur déporté intelligent doit être fixé à une structure bien solide de la toiture, du plafond, du mur ou du sol. Il est également possible d’installer le ventilateur déporté intelligent dans une structure spécialement montée ou existante. AVERTISSEMENT Risque du poids excessif 9.
Achever l’installation Déterminer et exécuter les découpes et trous nécessaires au passage du circuit d’évacuation. IMPORTANT : Lors des opérations de découpe et de perçage dans un mur ou un plafond, veiller à ne pas endommager les câblages électriques ou autres canalisations dissimulées. 1. Installer la hotte à son emplacement définitif. Pour ce faire, consulter les instructions d’installation fournies avec la hotte. 2.
Raccordement électrique AVERTISSEMENT Raccordement de la hotte et du ventilateur déporté intelligent 1. Mesurer la distance entre le ventilateur déporté intelligent et le boîtier de raccordement de la hotte. Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche. A Le non-respect de ces instructions peut causer un décès ou un choc électrique. Raccordement de la hotte 1.
Raccordement électrique de la hotte Raccordement du ventilateur déporté intelligent Raccordement électrique du ventilateur déporté intelligent 1. Utiliser un connecteur de fils (homologation UL ou CSA) pour raccorder les deux conducteurs noirs. 2. Utiliser un connecteur de fils (homologation UL ou CSA) pour raccorder les deux conducteurs blancs. 3. Utiliser un connecteur de fils (homologation UL ou CSA) pour raccorder les deux conducteurs rouges. 4.
4. À l’aide de l’adaptateur Torx® T10, ôter les 4 vis du couvercle du moteur du ventilateur. Retirer le couvercle du moteur et le mettre de côté. 7. Pousser le moteur du ventilateur pour dégager les deux languettes à ressort des orifices en trou de serrure situés en haut de la caisse de la hotte. C A A B A. Orifices en trou de serrure A. Couvercle du moteur du ventilateur B. Vis (4) C. Hotte 5. Déconnecter le moteur du ventilateur du câblage de la hotte.
11. Fixer le boîtier de raccordement métallique fourni avec le ventilateur déporté intelligent sur le dessus de la hotte au moyen des 2 vis de 3,5 x 6,5 mm. 3. Installer le raccord de transition sans clapet anti-reflux du côté inférieur de la base du ventilateur déporté. À l’aide de l’adaptateur Torx® T10, poser 2 vis de 3,5 x 9,5 mm pour fixer le raccord de transition à la base. A B C A. Base du ventilateur déporté B. Raccord de transition (sans clapet anti-reflux) C. Vis de 3,5 x 9,5 mm (2) 12.
8. Brancher le connecteur à 9 broches du moteur du ventilateur à son homologue à l’intérieur de la base du ventilateur déporté. Installation du ventilateur déporté intelligent Le ventilateur déporté intelligent doit être fixé à une structure bien solide de la toiture, du plafond, du mur ou du sol. Il est également possible d’installer le ventilateur déporté intelligent dans une structure spécialement montée ou existante. AVERTISSEMENT Risque du poids excessif 9.
Achever l’installation Déterminer et exécuter les découpes et trous nécessaires au passage du circuit d’évacuation. IMPORTANT : Lors des opérations de découpe et de perçage dans un mur ou un plafond, veiller à ne pas endommager les câblages électriques ou autres canalisations dissimulées. 1. Installer la hotte à son emplacement définitif. Pour ce faire, consulter les instructions d’installation fournies avec la hotte. 2.
Raccordement électrique AVERTISSEMENT 4. Connecter les 8 conducteurs dans le boîtier de raccordement de la hotte. Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche. Le non-respect de ces instructions peut causer un décès ou un choc électrique. Raccordement de la hotte et du ventilateur déporté intelligent 1.
Installation du ventilateur déporté intelligent Hottes série JXW85DS, JXI85DS, KVWB60DS et KVIB60DS Dépose du moteur du ventilateur de la caisse de la hotte AVERTISSEMENT 4. À l’aide de l’adaptateur Torx® T10, retirer les vis qui maintiennent le panneau de retenue du filtre à la hotte. Voir les illustrations suivantes pour connaître l’emplacement et le nombre de vis. Pour les hottes JXW85DS et JXI85DS A Risque de choc électrique B Déconnecter la source de courant électrique avant l'entretien.
5. Déconnecter le moteur du ventilateur du câblage de la hotte. À l’aide d’un tournevis à lame plate, appuyer sur la languette supérieure du connecteur électrique à 9 broches tout en appuyant sur sa languette inférieure. Débrancher le connecteur à 9 broches du moteur du ventilateur. 8. À l’aide de l’adaptateur Torx® T20® équipé d’une rallonge, ôter les 4 vis qui maintiennent le moteur du ventilateur à la caisse de la hotte et les mettre de côté. A ® 6.
14. Ôter les 2 opercules arrachables en haut du coffret électrique de la hotte et installer un serre-câble (homologation UL ou CSA) dans l’opercule avant. 15. Ôter le connecteur à 9 broches à l’intérieur du coffret électrique de la hotte. Insérer un tournevis à lame plate dans les languettes latérales tout en tirant le connecteur pour l’ôter (voir l’illustration suivante). 16. Couper l’attache-câble le plus proche du connecteur à 9 broches. 18.
22. Fixer le boîtier de raccordement métallique fourni avec le ventilateur déporté intelligent sur le dessus du coffret électrique de la hotte au moyen des 2 vis de 3,5 x 6,5 mm. A 3. Installer le raccord de transition sans clapet anti-reflux du côté inférieur de la base du ventilateur déporté. À l’aide de l’adaptateur Torx® T10, poser 2 vis de 3,5 x 9,5 mm pour fixer le raccord de transition à la base. B A B C C A. Base du ventilateur déporté B. Raccord de transition (sans clapet anti-reflux) C.
7. Placer la caisse du ventilateur déporté (avec son moteur) à proximité de sa base. 8. Brancher le connecteur à 9 broches du moteur du ventilateur à son homologue à l’intérieur de la base du ventilateur déporté. Installation du ventilateur déporté intelligent Le ventilateur déporté intelligent doit être fixé à une structure bien solide de la toiture, du plafond, du mur ou du sol. Il est également possible d’installer le ventilateur déporté intelligent dans une structure spécialement montée ou existante.
Achever l’installation Déterminer et exécuter les découpes et trous nécessaires au passage du circuit d’évacuation. IMPORTANT : Lors des opérations de découpe et de perçage dans un mur ou un plafond, veiller à ne pas endommager les câblages électriques ou autres canalisations dissimulées. 1. Installer la hotte à son emplacement définitif. Pour ce faire, consulter les instructions d’installation fournies avec la hotte. 2.
Raccordement électrique AVERTISSEMENT 5. Connecter les 8 conducteurs dans le boîtier de raccordement de la hotte. Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche. Le non-respect de ces instructions peut causer un décès ou un choc électrique. Raccordement de la hotte et du ventilateur déporté intelligent 1.
Installation du ventilateur déporté intelligent Hottes série WVW75UC et WV175UC Dépose du moteur du ventilateur de la caisse de la hotte AVERTISSEMENT 5. Ôter les 2 vis qui maintiennent la fixation isolante au moteur du ventilateur et les mettre de côté. 6. Déconnecter le moteur du ventilateur du câblage de la hotte. À l’aide d’un tournevis plat, appuyer sur la languette supérieure du connecteur électrique à 9 broches tout en appuyant sur sa languette inférieure.
9. Ôter les 2 opercules arrachables en haut du coffret électrique de la hotte et installer un serre-câble (homologation UL ou CSA) dans l’opercule avant. 10. Ôter le connecteur à 9 broches à l’intérieur du coffret électrique de la hotte. Insérer un tournevis plat dans les languettes latérales tout en tirant le connecteur pour l’ôter (voir l’illustration suivante). 11. Couper l’attache-câble le plus proche du connecteur à 9 broches. 13.
17. Fixer le boîtier de raccordement métallique fourni avec le ventilateur déporté intelligent sur le dessus du coffret électrique de la hotte au moyen des 2 vis de 3,5 x 6,5 mm. A 3. Installer le raccord de transition sans clapet anti-reflux du côté inférieur de la base du ventilateur déporté. À l’aide de l’adaptateur Torx® T10, poser 2 vis de 3,5 x 9,5 mm pour fixer le raccord de transition à la base. B A B C C A. Base du ventilateur déporté B. Raccord de transition (sans clapet anti-reflux) C.
8. Brancher le connecteur à 9 broches du moteur du ventilateur à son homologue à l’intérieur de la base du ventilateur déporté. Installation du ventilateur déporté intelligent Le ventilateur déporté intelligent doit être fixé à une structure bien solide de la toiture, du plafond, du mur ou du sol. Il est également possible d’installer le ventilateur déporté intelligent dans une structure spécialement montée ou existante. AVERTISSEMENT Risque du poids excessif 9.
Achever l’installation Déterminer et exécuter les découpes et trous nécessaires au passage du circuit d’évacuation. IMPORTANT : Lors des opérations de découpe et de perçage dans un mur ou un plafond, veiller à ne pas endommager les câblages électriques ou autres canalisations dissimulées. 1. Installer la hotte à son emplacement définitif. Pour ce faire, consulter les instructions d’installation fournies avec la hotte. 2.
Raccordement électrique AVERTISSEMENT 5. Connecter les 8 conducteurs dans le boîtier de raccordement de la hotte. Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche. Le non-respect de ces instructions peut causer un décès ou un choc électrique. Raccordement de la hotte et du ventilateur déporté intelligent 1.
SCHÉMA DE CÂBLAGE 1 BU GRIS N R M BL JA MAR 3 4 5 6 7 8 9 BU GRIS N R BL JA MAR JA/VE JA/VE JA/VE 2 SE14CA 61
Notes 62