iMPORTANT: Read and save these instructions. Quick Reference Table of Contents: Pages iMPORTANT: Installer: Leave Installation instructions with the homeowner. Homeowner: Keep Installation instructions for future reference. [_- Save Installation Instructions for local electrical inspector'suse.
Mobile home installation Yoursafety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING".
IMPORTANT: Observe all governing codes and ordinances. It is the customer's responsibility: eTo contact a qualified installer. electrical • To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 -- latest edition*, or CSA Standards C22.1-g4, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and ordinances.
u (10.2 cm) 6/8" (15.9 mm) 9" (22.9 cm) Dia. 5/8 (15.9 mm) \ 16" (40.6 cm) INTERNAL BLOWER MOTOR NOTE: A 10" (2.5 cm) round vent system adapter collar attaches over this hole. Adapter collar is supplied with exterior blower. / "_./_ 9-3/8" (23.8 cm) _ _ (20,8"cm) 16" 40.6 cm '_r_ ,_ EXTERIOR-MOUNTED BLOWER MOTOR 2-1/8" 64 cm (10.5 cm) See cooktop manufacturer's instructions for cooktop cutout depth and width. A = 1/2" (12.7 mm) mln.
27-1/2" (69.9 cm)for30"(76.2 cm)vent 33-1/2" (86.1 cm)for36"(91.4 cm)vent \ -,_. \ 1-7/8" (4.8 cm) Some models require a countertop deeper than 25" (63.5 cm); see cutout dimensions chart below. 1/4" (6.4 mm) A = 1/2" 1/2" (12.7 ram) min. cooktop (12.7 min. ram) X backsplash centerline of cooktop cutout It is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts to avoid mistakes.
Vent system installed under a concrete slab using PVC sewer pipe. 6" (15.2 cm/round Venting system must terminate the outside. to Island location 6" (15.2 cm) wall Do not terminate the vent system in an attic or other enclosed area. transition PVC pipe 6" (15.2 cm/ round metal vent {15.2 cm} round PVC ;oupling slab 6" {15.2 cm/ ; round PVC i Do not use plastic or metal foil vent. &_n coupling vent 6" (15.2 cm/ round 90° PVC sewer pipe elbow Vent work needed for installation is not supplied.
6" (15.2 cm) round vent system 90 ° elbows Maximum ,_--6 ft. (1.8 m) -:_-I length I over counter support arm = 35 ft. (8.9 m) 1 - wall cap 8ft. (2.4 m) straight 2-90 ° elbows Transition =Oft. =8ft. =lOft. =4.5 ft. Length of 6" (15.2 cm) system = 22.5 ft. (6.8 m) Recommended fittings easily assemble the downdraft vent system. Remove parts packages, downdraft vent and blower box from carton and set on protective surface.
12= bracket for rear venting Excessive Disconnect Weight Hazard power. green ground screw Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury. d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown.Then reinstall screws. e. Reinstall blower in blower box with mouth of blower pointing out open side of blower box. Secure blower to blower box with 6 Phillips-head screws.
6[] Turnthe controlknobon sideof ventto checkthe operationandspeedof blower. If blowerdoesnot operate: • Checkthat filter or filters are pressedin asfar as theywill go. Checkthat circuitbreakeris not tripped or housefuse blown. Disconnectpower.Checkthat wire connectionshavebeen madecorrectly. • Reconnectpower. 7= Connectvent systemto blower.Ventsystemmustendwith a wall or roof cap.Useduct tapeto sealalljoints.
Recommended fittings standard ,__ upport leg cabinet floor. Align top of legs with pencil marks on face of downdraft vent.Tighten screws in legs. 7= 90 ° elbow = 5 ft. (1.5 m) 45 ° elbow = 2.5 f_. (0.8 m) = Attach support legs to side of downdraft vent with two screws in each leg. Do not tighten screws. Excessive = Put on gloves and safety glasses. Place cardboard or another form of protection on top of a flat surface where you can easily assemble the downdraft vent system.
[] Insertretractable downdraftvent into countertop cutout.Twopeopleare recommendedto supportthe weight of the downdraftvent duringlifting. Positiondowndraft vent so it is centeredin cutoutand parallelto edgeof cutout.Check that downdraftvent is vertical.Then attachlowersupportlegsto cabinet floor with screws. 15= microswitches ON/OFF vent box knockout \ wiring cover box ground _filter or filters depending on model 6_ ___.
Theretractable downdraftventsystemis designed to removesmoke,cookingvaporsandodorsfromthecooktoparea. Forthebestresults,theventshouldbeoperatingbeforecookingis started.If youuselargeor tall utensils,placethem onthelargerearelementor burnersurface.A higherheatsettingthannormallyusedmaybeneededwhenthe downdraftventis operating. WARNING--TO REDUCETHE RISKOFFIRE, ELECTRIC SHOCK,ORINJURYTOPERSONS, OBSERVETHE FOLLOWING: Usethis unit only in the mannerintendedby the manufacturer.
If retractabledowndraftvent does not operateaftercleanfilters havebeenreinstalled: Pushthe filter in asfar asit will go.Whenthe filter is removed, the microswitchbehindthe filter is inactivated.Thissafetyfeature stopsthe blowerandraising mechanismuntilthe filter is properlyreinstalled. microswitches _tal filter behind filters models right metal filter microswitches behind filter are included For model series KIRD &YKIRD 801,802 For model series GZ &YGZ 7930 30" (76.2 cm) one-piece trim: Part No.
ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will pay for FSI_ replacement parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. ITEMS WHIRLPOOL WILL NOT PAY FOR 1.
identify the brand of your vent system and, as appropriate, call the KitchenAid Customer interaction Center toll-free at 1-800-422-1230 or call the Whirlpool Customer interaction Center toll-free at 1-800-253-1301. Our consultants are available to assist you. When calling: Please know the purchase date, and the complete model and serial number of your appliance This information will help us better respond to your request.
Part No. 4329225/9763381 _) 2005 Whirlpool Corporation _ Registered trademarkF Mtrademark of KitchenAid, U.S.A., KitchenAid Canada licensee in Canada 16 Printed in Italy.