CHANGING THE BIN DOOR AND LOWER PANEL The storage bin door and lower panel are designed to accept an optional decorative wood panel of your choice. The wood panel should be no more than VI inch (6 mm) thick. Cut it to the same size as the production metal panel. See Figure 1. To change the bin door panel: 1. Open the bin door. DOOR BIN 11’Y.” LOWER PANEL ll’y,e” c I- (285 mm) (303 mm) 2. Remove the two screws on top of the door which hold the handle. WOOD PANEL DIMENSIONS (43 mm) A FIGURE 1 3.
GENERAL INFORMATION 2 Either a gravity drain system or a sump pump to lift the water to an existing drain. 3 An electrical branch circuit of 115 Volt, 60 Hz, 1 phase, with a 15 Amp delayed action fuse or circuit breaker. . UNPACK l INTERIOR PACKING LOCATE UNIT THIS UNIT MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS, SUCH AS WIND, RAIN, WATER SPRAY OR DRIP. OPEN BOTTOM FLAPS 1 BEST \ RANGE (21.1%) 70°F H CR 66 A FIGURE 4 FIGURE 3 (32.
FOR THE PLUMBER . CONNECT TO WATER . CONDENSATE PUMP (observe local codes) 1 When drain connection below the level of the unit is not available a condensate pump may be used to lift the water to an available drain. 1 Use l/4” (6 mm) OD soft copper tubing for the cold water supply. 2 2 Provide a convenient water line. manual shut-off valve in the 3 Position the t u b’rng so it can enter the access located in the right-hand rear of the cabinet.
REMOVE SHUNT PLUG IN CONDENSATE PUMP - SCREWS FIGURE 5C FIGURE 5B FOR THE ELECTRICIAN 3-PRONG GROUNDING TYPE WALL RECEPTACLE II II ELECTRICAL REQUIREMENTS A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical supply is required (time delay fuse or circuit breaker is recommended). It is recommended that a separate circuit, serving only this appliance, be provided. DO NOT use an extension cord. ELECTRICAL APPLIANCE.
inspector), a temporary adaptor may be plugged into the existing 2-prong wall receptacle to mate with the Bprong power supply cord. See Figure 7. THIS, HOWEVER, IS NOT RECOMMENDED. eleCtriCal NOTE: If this is done, you must connect the grounding eyelet on the adapter to the wall receptacle cover plate screw and from this same screw, you must connect a separate copper ground wire (No. 4 minimum) to a grounded cold water pipe*. See Figure 7. Do not ground to a gas supply pipe.
UNIT WIRING DIAGRAM THINGS TO REMEMBER This model operates at 115 volts except for the cutter grid circuit which operates at 8.5 volts at 1 amp. 0 Water enters only during the defrost cycle. Therefore the first cycle will be completed without water in the system. 0 As the room and water temperatures vary, so will the amount of ice produced. This means that higher operating temperatures will result in reduced ice production.
CHECK OPERATION CUBELET CUTTER GRIDS Start the unit by turning the service switch to “ON” and opening the line water valve. NOTE: Left is “OFF”-Middle is “ON”--Right is “CLEAN.” In “CLEAN” position, only the pump operates. 19mmx19mm Check condenser fan to make sure it is revolving. Water will not enter pump pan until freezing plate gets cold and machine goes into a harvest cycle. Check for even water flow over freezing plate. Unit must be level for proper operation.