Part No. 3186508 Rev. A A l l l l WARNING ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT INSTALL ANTI-TIP DEVICE PACKED WITH RANGE SEE INSTALLATION INSTRUCTIONS IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave installation Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference. Save Installation Instructions for local electrical inspector’s use.
Cabinet opening dimensions Before you start... Read electrical, gas and carpentry instructions. Proper installation is your responsibility. Fdr minimum clearance to the top of the cooktop, see Note.“” A qualified technician should install this range. Make sure you have everything necessary for correct installation. It is the customer’s responsibility to make sure that the countertop has been properly prepared and that the installation clearances specified on the serial/rating plate are met.
Tools and materials needed for installation: gas line shutoff valve L.P.-resistant pipe-joint compound A.G.A. design-certified flexible metal connector (4-5 feet) 2 flare union adapters for connection to pressure regulator (112” NPT x 112” or 314 ’ I.D.) l l l l 318” ratchet Electrical requirements If local codes permit, a new A.G.A. design-certified, 4-5 foot long, l/2” or 314” I.D., flexible metal appliance connector is recommended for connecting this range to the gas supply line.
Electrical connection Now start... With range in kitchen. Electrical Shock Hazard Electrical ground is required on this appliance. l Do Not connect to the electrical supply until appliance is permanently grounded. l Disconnect power to the junction box before making the electrical connection. l This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.
Fire Hazard Do Not make connection too tight. The regulator is die cast. Over-tightening may crack the regulator, resulting in a gas leak and possible fire or explosion. flexible pressur; regulator and normally open valve assembly connector manual shutoff valve (See Steo F on Panel B for prober location.) . ml I Open shutoff valve in gas supply line. Wait a few minutes for gas to move through the gas line. Fire Hazard Do Not use an open flame to test for leaks from gas connections.
Electronic Ignition System initial lighting and gas flame adjustments. Cooktop burners use electronic ignitors in place of standing pilots. When the cooktop control knob is turned to the “HI” position, the system creates a spark to light the burner. This sparking continues until the burner has a flame. HI 115.1 Check the operation of the cooktop burners. Push in and turn each control knob to the “HI” position. The flame should light within 4 seconds. Check each cooktop burner for proper flame.
If range does not operate... l l l Check that the circuit breaker is not tripped or the house fuse blown. Check that gas valves are turned to “ON” position. A more detailed troubleshooting checklist is provided in the Use and Care Guide. NOTE: Refer to Use and Care Guide for operating instructions and cleaning For cleaning and maintenance... If you need assistance... If removing the range is ever necessary for cleaning or maintenance, shut off gas supply to range.