STR250R01C Operating Manual 2011. 6.
Content 1. Introduction....................................................................................................................................................................5 1.1. 2. System Network Configuration............................................................................................................................5 2.1. 3. 4. General Introduction............................................................................................................................
6.7. Toolbar............................................................................................................................................................... 35 6.8. Program operation...................................................................................................................................... 36 6.9. 6.8.1. Initiating communication ........................................................................................................... 36 6.8.2. Disconnect....
IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
1. Introduction 1.1. General Introduction As an equipment to clear RF shadows inevitably generated between the adjacent cells of CDMA, STR250R01C supports CDMA and effectively repeats the signals between mobile terminals in weak coverage area and BTS. This equipment is Dual Band Optical DAS that support 850MHz and 1900MHz bands simultaneously, and it is designed to support CDMA for each band.
Max loss of optic cable (between RHU and RU): 2 ~ 10dBo 2 coverage ANT ports on RU. (Separate Ant. Ports for 850MHz and 1900MHz) 2 link ANT ports on RHU. (Separate Ant. Ports for 850MHz and 1900MHz) [Network Configuration of Dual Band Optical DAS] 3. System Specifications 3.1. General Specifications Item RHU RU Enclosure Type Cabinet Cabinet Dimension WHD 471.7(H) X 263.4(W) X 304.8(D)mm 471.7(H) X 263.4(W) X 304.8(D)mm (mm) Weight 26.5 Kg 26.
3.2. System specifications 3.2.1. Frequency allocation 1900MHz Band 850MHz Band 3.2.2. System Specifications Item Specification Tx Frequency Range Contiguous 25MHz Bandwidth in 1930 ~ 1990MHz Contiguous 25MHz Bandwidth of 869 ~ 894MHz Rx Frequency Range Contiguous 25MHz Bandwidth in 1850 ~ 1910MHz Contiguous 25MHz Bandwidth in 824 ~ 849MHz Frequency Stability No of Carriers Supported System Delay Tx-Rx Isolation Impedance Pass-Band Ripple Remarks 0.
FWD Input Power -55 dBm/total Each Band FWD Output Power 40dBm /total for 1900MHz RU ANT Port 40dBm /total for 850MHz RU ANT Port RVS Input Power -68 dBm/total max. at RU each ANT Port RVS Output Power System Gain FWD Spurious 27dBm/total max. at RHU each Rx ANT Port FWD: 95dB max. RVS: 95dB max. Comply to 3GPP2, FCC regulation RVS Noise Figure 10dB max. @ 95dB Gain Gain Control Range FWD: 20dB by 1dB Step VSWR Optical Wavelength RF I/O Connector Max. Gain RVS: 20dB by 1dB Step 1.5 : 1 max.
4. Mechanical Specifications 4.1. STR250R01C RHU 4.1.1.
/ 56
4.1.2. Dimension RHU System picture and Size 471.7(H) X 263.4(W) X 304.8(D) mm [Side] 4.1.3. [Inner Side] [Front/Rear Side] Mechanical Specification No Item Description 1. Dimension: 471.7(H) X 263.4(W) X 304.8(D) mm 1 Dimension & Weight (plinth included) 2. Weight: 26.5 Kg 2 Method of Cooling Natural convection (Heat-sink) 3 Door Locking Type 10 on each side using bolt lock 1. Position: Cabinet inside 4 Optic Connector 2.
4.1.4. Description of STR250R01C RHU [Forward Path] The signal from CDMA BTS is fed to the RF link antenna port of RHU. First, RHU Filter rejects the unwanted signal. Then LNA and Up-down converter make gain for transmitting. Combiner combines the signal with the modem signal (360MHz). The combined signal gets transmitted to RU via optical cable.
4.1.8. Module Composition of RHU Module operational voltage table No Module Voltage Used 1 3-Way Combiner 2 RHU FWD Band Selector for 1900MHz (RHFBS) 5.5Vdc /6.5Vdc 3 RHU FWD Channel Selector for 850MHz (RHFCHS) 5.5Vdc /6.5Vdc 4 Doner Optical Transceiver Unit (DOU) 5 RF Modem (FSK Modem) 6 RHU RVS COM for Signal combing (RRCOM) 7 RHU RVS Band Selector for 1900MHz (RHRBS) 6.5Vdc 8 RHU RVS Band Selector for 850MHz (RHRCHS) 6.
4.1.9. Function of Modules No Module Description [3-Way Combiner] 1 Combine signals into RF and modem signals and sends to DOU. [RHFBS] 2 Controls the gain of 1900MHz FWD path, filters FWD band, and performs the ALC function. Output of the module is sent to 3-Way Combiner. [RHFCHS] 3 Controls the gain of 850MHz FWD path, filters FWD band, and performs the ALC function. Output of the module is sent to 3-Way Combiner. [DOU] 4 Performs E/O (or O/E) conversion for FWD and RVS signals.
[RHRCHS] 8 Amplifies RVS 850MHz signal, filters for the desirable band and controls the RVS path gain of RHU. [RX HPA 1900] 9 27dBm High power amplifier that amplifies the RHU 1900MHz signal by linearizer and sends to RHU ANT through the 1900MHz FE-Duplexer. [RX HPA 850] 10 27dBm High power amplifier that amplifies the RHU 850MHz signal by linearizer and sends to RHU ANT through the 1900MHz FE-Duplexer.
[Interface BD] Provides operating voltage and monitors/controls 15 signal to modules connected to interface B’D. Also provides a connection port to communicate with NMS B’D.
Power Distribution Diagram 17 / 56
4.2. STR250R01C RU 4.2.1.
/ 56
4.2.2. Dimension RU System picture and Size 471.7(H) X 263.4(W) X 304.8(D) mm [Side] 4.2.3. [Inner Side] [Front/Rear Side] Mechanical Specification No Item Description 3. Dimension: 471.7(H) X 263.4(W) X 304.8(D) mm 1 Dimension & Weight (plinth included) 4. Weight: 26.5 Kg 2 Method of Cooling Natural convection (Heat-sink) 3 Door Locking Type 10 on each side using bolt lock 3. Position: Cabinet inside 4 Optic Connector 4.
4.2.4. Description of STR250R01C RU [Forward path] The RF and modem combined signals sent from the optic module of RHU is first divided into RF and modem signals at Divider in RU, then the 1900MHz Tx RF signal is amplified and filtered at the RFBS module, 850MHz Tx RF signal is amplified and filtered at the RFCHS module. The modem signal is conveyed to CPU of NMS controller through FSK modem. CDMA signal is reduced by the Crest Factor passing through the CFR FPGA digital board inside RFBS and RFCHS.
4.2.5.
4.2.6.
Module operational voltage table No Module Voltage Used 1 Divider 2 RF FWD Band Selector for 1900MHz (RFBS) 5.5Vdc /6.5Vdc 3 RF FWD Channel Selector for 850MHz (RFCHS) 5.5Vdc /6.5Vdc 4 Slave Optical Transceiver Unit (SOU) 5 RF Modem (FSK Modem) 6 RU RVS COM for Signal combing (RRCOM) 7 RU RVS Band Selector for 1900MHz (RRBS) 6.5Vdc 8 RU RVS Band Selector for 850MHz (RRCHS) 6.
4.2.7. Function of Modules No Module Description [Divider] 1 Divides signals into RF and modem signals and sends to RFBS/RFCHS and FSK modem. [RFBS] Controls the gain of 1900MHz FWD path, filters 2 FWD band, controls the crest factor of 1900MHz FWD signal, and performs the ALC function. Output of the module is sent to 1900MHz HPA. [RFCHS] Controls the gain of 850MHz FWD path, filters 3 FWD band, controls the crest factor of 850MHz FWD signal, and performs the ALC function.
[1900MHz HPA] 16Watt(42dBm) 9 High power amplifier that amplifies the RU 1900MHz signal by linearizer and sends to RU ANT through the 1900MHz FEDuplexer. [850MHz HPA] 16Watt(42dBm) 10 High power amplifier that amplifies the RU 850MHz signal by linearizer and sends to RU ANT through the 850MHz FEDuplexer. [1900MHz FE-Duplexer] 11 Front end duplexer that passes through 1900MHz desired FWD and RVS frequency bands.
Power Distribution Diagram 27 / 56
5.
6. Administration Program (RptMan-STR250D01C) Administration program (RptMan-STR250D01C) is a management program for STR250D01C and provides status monitoring and controlling functions to users. 6.1. System Requirement System: Desktop or laptop PC (highly recommended that PC supports Bluetooth interface.) OS: Windows XP or later version. GUI developed under XP. Resolution: 1024 768 or more Connection Cable: 9 pin serial cable (cross type) 6.2.
When finding remote Bluetooth devices is finished, select the device name installed in RHU. If you can see device name started with “SD1000”, that may be correct. If you can see multiple devices, you have to know which is correct to connect. After selection, press “Next” button. Type security code and press “start pairing” button. Default security code is “1234” Select and check the service named “Generic Serial”, then press “Configure” button.
Keep in your mind the device and COM port name. Press “OK” button. Press “Next” button Finish the creating the new virtual COM port to connect to RHU.
A new connection is created and connected to remote “RHU”. Disconnect the connection to make it free. Local GUI will use this freed serial port. When the local GUI started, you can establish a connection and communicate with “RHU” via it. 6.3.
Section Description Displays Window Title the name of management program(GUI), i.e. RptMan- STR250R01C. Displays the type of equipment currently connected to the program (RHU or RU). Menu Bar Presents working menu for operators. It is associated with tool icons, which can activate the tool bar menus. Toolbar Presents icons (button type) for frequently used commands. User-friendly icons are used. Icons are activated or disabled as to the status of repeater.
Status of repeater is displayed by LED’s and values. LED / Alarm: On/Off: blinking indicates ALARM, ON, indicates NORMAL OFF Exception) for HPA, is ON, is OFF Value Units are not displayed. Value displayed in box ( ) Control The shape of mouse cursor is changed to on controllable items. The texts of controllable LED or values are displayed in BOLD font. 6.5. Control Policy Basically, user can change one item at a time.
RHU image download Downloads compressed firmware file to RHU equipment RU image download Downloads compressed firmware file to RU equipment Factory Setting Restores all parameter values to initial factory settings System action Not available Gain Setting Tx: change system gain to setup remote output to predefined level (about 30 dBm). Rx: set ATT to have 40dB of Rx total gain from RU to RHU including optical loss.
RHU Download Download RHU firmware files to RHU equipment. RU Download Download RU firmware files to RU equipment. RHU Factory Initialize RHU parameters to factory setting values. Setting RU Factory Restores RU parameters back to original factory setting values. Setting Help Shows version information 6.8. Program operation 6.8.1.
Method Click Description The communication between GUI and repeater becomes disconnected. button in toolbar of GUI program 6.8.3. STR250R01C Brief System Status (Block Diagram View) (1) Node Tree: This window displays the tree configuration of RUs connected with RHU Nose Tree VzW RHU Double click to open the RHU status window VzW RUDUAL-1 Double click to open the RU status window.
Device RHU Category Item IN PWR : Tx Input Power IN UPR : Tx Input upper limit value and alarm represented by LED. IN LWR : Tx Input lower limit value and alarm represented by LED. ATT LD PWR : detected LD power and LD bias alarm. LD LWR : LD power lower limit value and alarm LED PD PWR : detected PD power and PD fail alarm detected by optic module. PD LWR : PD power lower limit value and alarm LED IN PWR : detected Rx input power.
OUT PWR : detected Tx output power OUT UPR / OUT LWR : upper and lower limit value and alarm LED ALC : turn on / off ALC function block and ALC level value. ASD : turn on / off ASD function block and its activation level. See RHU. Protection On/Off : turn on / off Rx protection function block. Pilot On/Off : turn on / off piolot to check Rx gain. It may be automatically turned off after reboot.
6.8.4.
Group Description Version: Firmware Versoin Type: Repeater unit type Name: ID of RHU for the communication Gain Setting TX: sets ATT to have 30dBm of output at the RU ANT Port User Connect: Connection status of COM port of repeater PSU: Status of PSU TMPCUR: Current temperature of the equipment TMPUPR: set the upper threshold value of temperature (button) and alarm status (LED) Install: This sets up the RU to communicate with RHU.
Bypass ON : turn on / off bypass function. FPGA Ver : shows version information. When “F.F” is showed, communication with FPGA is not stable. IN PWR : detected input power before filter. ALC : ALC level and on/off status. ALC ATT : added ATT value by ALC feature. OUT PWR : last Tx output power after filter. PLL : PLL lock status of internal PLL module. Output On/Off : turn on/off information of Rx HPA IN PWR : detected Rx input power.
6.8.5. STR250R01C RU Status Window Group Description Version: Firmware version Type: Type of repeater Name: Set the Name, ID, Serial No.
LDPWR: Value of LD power (box) and status of LD (LED) LDLWR: Value/control of lower threshold of LD power (button) and lower alarm status of LD power (LED) PDPWR: Value of PD power (box) and status of PD (LED) PDLWR: Value/control of lower threshold of PD power (button) and lower alarm status (LED) RU parameters for PCS/Cellular band are displayed by the tab selection. Each band has the identical items which can be monitored and controlled.
Cellular Spectrum View Window Center: CDMA CH for center freq.
6.8.6. Firmware download Firmware download is performed when system needs to be updated. Downloading improper images (executable file of repeater CPU) may cause harmful damages to equipment. The following steps should be taken for firmware download. ① Convert firmware source file (*.bin) to a downloadable file format. Main menu: Action → Image Compression, toolbar: ② Open a pop-up window showing the status of the target equipment for firmware download.
Download procedure : Display selected file information Select file Perform operation Display progress of firmware download 47 / 56
6.9. Additional features 6.9.1. ASD (Auto Shutdown) Function 1. If the power level is above the shut down level for longer than 1 second, turn off HPA. 2. During shutdown state, monitor RU input power. If the level is below 5dB from shut down level, turn on HPA automatically. 3. Monitor HPA output power in normal operation, and monitor RU input power during shut down. Longer than 1 sec, HPA off 6.9.2. ALC (Auto Level Control) Function 1.
6.9.3. Center Channel Selection RHU and RU can cover only 25MHz band width. For Cellular band, it will be OK, But for PCS, user have to choose proper center channel of device. It seems to sliding window. User can specify center channel as following table: Step Descriptions Activated dialog by click Select center channel. (for Cellular, center channel cannot be changed) Select channels in-serviced. You can select them by : Individual channel Band name e.g.
Refresh all values every 1 sec. It is useful, if you want to check current service channel.
Appendix A Factory setting value for each equipment RHU Item RU Value Item Value RHU TEMP UPR 80 RU TEMP UPR 90 1900/850MHz Tx IN UPR -25 Tx ATT1 31.5 1900/850MHz Tx IN LWR -63 Tx ATT2 (Hidden ATT) N.A PLL N.A Optic LD LWR 0 Optic PD LWR -10 HPA-850, HPA1900 On/off Off Tx ATT1, ATT2 31.5 HPA-850, HPA-1900 OUT UPR 42 Center N.A HPA-850, HPA-1900 OUT LWR 20 FA Info N.
Appendix B Cellular CDMA Frequency Map Sub- Channel Band # A1 B1 A2 DL (MHz) UL (MHz) Remarks 1019 869.88 824.88 DL : 869.265~879.105MHz 37 871.11 826.11 UL : 824.265~834.105MHz 78 872.34 827.34 119 873.57 828.57 160 874.8 829.8 201 876.03 831.03 242 877.26 832.26 283 878.49 833.49 384 881.52 836.52 DL : 880.905~889.515MHz 425 882.75 837.75 UL : 835.905~844.515MHz 466 883.98 838.98 507 885.21 840.21 548 886.44 841.44 589 887.67 842.67 630 888.9 843.
Appendix C PCS CDMA Frequency Map Sub- Channel Band # A D B E F DL (MHz) UL (MHz) Remarks 25 1931.25 1851.25 DL : 1930.625~1944.375MHz 75 1933.75 1853.75 UL : 1850.625~1864.375MHz 100 1935.00 1855.00 125 1936.25 1856.25 150 1937.50 1857.50 175 1938.75 1858.75 200 1940.00 1860.00 225 1941.25 1861.25 250 1942.50 1862.50 275 1943.75 1863.75 325 1946.25 1866.25 DL : 1945.625~1949.375MHz 350 1947.50 1867.50 UL : 1865.625~1869.375MHz 375 1948.75 1868.
C1 C2 850 1972.50 1892.50 875 1973.75 1893.75 925 1976.25 1896.25 950 1977.50 1897.50 975 1978.75 1898.75 1000 1980.00 1900.00 1025 1981.25 1901.25 1050 1982.50 1902.50 1075 1983.75 1903.75 1100 1985.00 1905.00 1125 1986.25 1906.25 1150 1987.50 1907.50 54 / 56 UL : 1890.625~1894.
* Auto gain control function RF Head Unit [RHU] Filtering ATT DNC LNA ADC f(n TS) FPGA UPC ATT 850MHz DL UPC ATT 1900MHz DL DAC BPF Link ANT [850MHz] INPUT DETECT RHFCHS [850MHz] DOU Filtering ATT RHFE- DUP [850MHz] DNC LNA ADC f(n TS) FPGA DAC BPF INPUT DETECT LD 3-Way DU Controller 360MHz FSK Modem 340MHz PD RS-232 WDM Coupler RHFBS [1900MHz] 850MHz UL RHRCHS [850MHz] UPC ATT f(n FPG TS ) A DAC PA 1900MHz UL ADC Filtering 850MHz PA RRCOM DNC RHRBS [1900MHz]
levels respectively for ALC and ASD to protect the system from overpower. On the Rx path, the default gain is set to put out 20 dBm, which is 7 dB lower than the maximum output power with consideration of traffic fluctuation of the mobile station. If different output level is desired, Rx ATT value of RU can be set manually to change output power level. When output power level is manually changed by adjusting Rx.