PW1900-C User Manual Kisan Telecom 2010.
Content 1. Introduction....................................................................................................................................................................5 1.1. 2. General Introduction.....................................................................................................................................5 Network configuration of system .......................................................................................................................5 2.
6.5. Control Policy................................................................................................................................................. 27 6.6. Menu .................................................................................................................................................................. 27 6.7. Toolbar.......................................................................................................................................................
IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
1. Introduction 1.1. General Introduction As an equipment to clear the shadows inevitably generated among the adjacent cells of CDMA, PW1900-C can supports CDMA application and effectively repeats the signals between terminals in dead area and BTS. The main objectives of PW1900-C are as follows: - The expansion of service coverage - The enhancement of service quality at the specific areas such as in tunnel or inbuilding - The enhancement of signal strength at the places where the signal is weak 2.
System configuration MHU Capacity: 1 Optical Branch/DOU and 6 DOU/MHU (6 Optical Branch/MHU) System Connection: Optic cable between MHU and RU Optic Wavelength: 1310nm for FWD, 1550nm for RVS Max loss of optic cable (between MHU and RU): 1 ~ 10dBo 3. System Specifications 3.1. General Specifications Item PW1900-C MHU PW1900-C RU 7U-Shelf type Enclosure Type 19” standard rack mountable Cabinet In-door use Dimension WHD 19"(482.
3.2. System specifications 3.2.1. Frequency allocation 3.2.2. System Specifications Item Specification Tx Frequency Range Any 25MHz Bandwidth in 1930 ~ 1990MHz Rx Frequency Range Any 25MHz Bandwidth in 1930 ~ 1990MHz Frequency Stability 0.002PPM Capable No of FA. 8FA System Delay DL: 8usec max. Remarks UL: 5usec max. Tx-Rx Isolation 100dB min. Impedance 50 Ohm Pass-Band Ripple 3dB max.
4. Mechanical Specifications 4.1. PW1900-C MHU 4.1.1.
[MHU composition] 9 / 37
4.1.2.
4.1.3. Mechanical specification No 1 Items Exterior view Specifications 1. Shelf attachable type to both INDOOR and OPEN RACK 2. W 19"(482.4) X H 310(7U) X D 450mm 3. Weight: 15.5 Kg (1DOU included) 2 Material Aluminum (AL5052, AL6063) is mainly used for protection from corrosion by external environments. 3 Connector Type 1. Optic I/O: FC/APC at front side 2. RF I/O: SMA Female at rear side 3. Monitor port: SMA Female at front side 4 Power Input 1.Power: 110-120Vac, 60Hz 2.
4.1.5.
8 Optic Connector PWR 9 LED2 FC/APC, optic connector DC power supply status of the DOU Card LD LD Alarm, Green: Normal, Red: Alarm PD PD Alarm, Green: Normal, Red: Alarm 10 RJ45(Master) 11 NMS board 12 AC INPUT 13 Tx IN 14 Rx OUT Connection port to the master for the NOC Sliding type External AC power input port (rear part) MHU FWD RF connection port from BTS (rear part) MHU RVS RF connection port to BTS (rear part) 13 / 37
4.1.6. Module Composition ① [NMS UNIT] ③ ④ ② ⑤ [PSU] No [DOU] Module ① MHU NMS Controller ② MHU PSU(Power Supply Unit) ③ MRFCOM(MHU RVS FWD Combiner) ④ MHU FSK Modem ⑤ MHU Optical Transceiver Unit (DOU) Voltage Used 9Vdc 9Vdc/6.5Vdc 6.5Vdc 9Vdc 6.
4.1.7. Function of modules No Module Functions [MHU NMS Controller] 1 Monitors/controls the status and configurable items of each module in MHU [PSU] 2 Converts AC110V into DC9V and DC6.5V, and provide them to each module in MHU [MRFCOM] Detect the FWD/RVS RF signal power level of 3 input/output ports of the MHU. Also provide the connection pin to FSK modem and this module has -20dB monitor port of module output.
4.1.8. PSU PSU converts external AC110V into DC and supplies +9V, +6.5V to each module in MHU. The drawing of PSU is as follows. OUTPUT SWITCH AC_L +9V GND +9V GND +6.5V GND AC_N INPUT +6.5V GND ALM GND F.G YW396-05V(연호전자) PWRON [PSU Capacity] Output Maximum Voltage current +9V 3A +6.5V 5A Watt 59.5 W [PSU Pin Map] SWITCH PIN Type: YW396-02V Pin no. 1 2 Spec. Switch_IN Switch_Out INPUT PIN Type: YW396-05V Pin no. 1 2 3 4 5 Spec. AC_L N.C AC_N N.C F.
OUTPUT PIN type: 5566-10 (MOLEX) Pin no. 1 2 3 4 5 Spec. ALARM +6.5V +6.5V +9V +9V Pin no. 6 7 8 9 10 Spec.
4.2. PW1900-C RU 4.2.1.
4.2.2. Dimension RU System Size 470(L) X 230(W) X 300(D) mm 4.2.3. Mechanical Specification No Item Description 1. 1 Dimension & Weight Dimension: 470(L) X 230(W) X 300(D) mm (plinth included) 2. Weight: 23Kg 2 Method of Cooling Natural convection (Heat-sink) 3 Door Locking Type Two locks on the left side of the front of cabinet 4 Optic Connector 1. Position: Cabinet inside 2. Connector type: FC/APC * Optic cable tray is provided inside of cabinet. 5 ANT PORT 1.
6 Power Input 7 Ground 8 Waterproof condition 9 Misc. Features 1. Power: 110VAC 2. Position: bottom side of cabinet 3. Connector: MS3106A 16-10S 2Hole 16SQ at the left side of cabinet IP65 compliant 1. Easy to maintain 2. Pole mountable (i.e., telegraph pole) 3. Lamp embedded with automatic On/Off function according to the door opening status 4. Torque hinge used 4.2.4.
4.2.5. Port Configuration No Item Description 1 AC INLET AC 110V Power Cable Connection 2 ANT Port Antenna RF cable connection port 3 Monitor Port 4 Optical Cable INLET A monitor port coupled by -40dB compared to the output power of the ANT Port Optic cable connection hole 4.2.6.
Module operational voltage table No Module Voltage Used 1 Divider 2 RF FWD Band Selector for 1900MHz (RFBS) 6.5Vdc 3 Slave Optical Transceiver Unit (SOU) 6.5Vdc 4 RF Modem (FSK Modem) 5 RU RVS COM for Signal combing (RRCOM) 6 RU RVS Band Selector for 1900MHz (RRBS) 7 RU RVS LNA for 1900MHz (RRLNA-WG) 9Vdc 8 HPA for 1900MHz 29Vdc 9 Front-End Filter Unit (FE-Duplexer) for 1900MHz 10 PSU 11 NMS Controller 12 Back Board Ass’y 9Vdc 6.5Vdc 110Vac 9Vdc 6.
4.2.7. Function of Modules No Module Description [Divider] 1 Divides RF signal to CDMA signal and modem signal, and sent to RFBS and FSK modem. [RFBS] Controls the gain of FWD output signal, filtered 2 FWD band, control the crust factor of RF signal, and perform the ALC function. The module output is sent to HPA. [SOU] 3 Converts E/O (or O/E) of FWD and RVS signals.
[HPA] 8 16Watt(42dBm) High power amplifier that linearly amplifies the RU CDMA signal and send to RU ANT through the FE-Duplexer. [FE-Duplexer] 9 Front end duplexer that passes through desired FWD and RVS frequency bands. [PSU] 10 Converts AC 110V to DC 29V / 9V / 6.5V / 5.5V, and distributes the voltages to each modules. It has RU AC power on/off switch. [NMS] 11 Monitors the status of RU each module, and controls the configurable items of the RU modules.
5. Administration Program (RptMan1900) Administration program (RptMan1900) is a management program for PW1900-C and provides status monitoring and control functions to users. 5.1. System Requirement System: Desktop or laptop PC OS: Windows XP or later version Resolution: 1024 768 or more Connection Cable: 9 pin serial cable (cross type) 5.2. Cable connection The cable connection between repeater and PC (GUI program) is illustrated below.
5.3. Screen Menu Bar Title Toolbar Node Tree Work Space Section Description Displays the name of management program (GUI), i.e. RptMan- Window Title PW1900. Displays the type of equipment which is currently connected to program (MHU or RU). Menu Bar Presents working menu for operators. It is associated with tool icons, which can activate the tool bar menus. Toolbar Presents icons (button type) for frequently used command. User friendly icons are used.
including optical loss. View Window MHU Window Presents MHU status window in work space Remote Window Presents RU status window in work space Cascade Cascade or tile horizon arrangement of repeater status Tile Horizon windows in work space Presents debug window in work space displaying packets Packet Debug between repeater and GUI program About RptMan1900 Help Displays version of GUI program named RptMan (Repeater Manager) 5.7.
5.8. Progrm operation 5.8.1.
5.8.3.
User Connect: Connection status of COM port of repeater PSU: Status of PSU TMPCUR: Current temperature of the equipment TMPUPR: set the upper threshold value of temperature (button) and alarm status (LED) LD Power: Transmitted optical power level to RU LD Lower: Lower limit level of the LD power PD Power: Received optical power level from RU PD Lower: Lower limit level of the PD power 1900 Tx Input: Tx level input from 1900MHz BTS 1900 Tx Upper: Upper limit of Tx input level 1900 Tx
5.8.4.
LDPWR: Value of LD power (box) and status of LD (LED) LDLWR: Value/control of lower threshold of LD power (button) and lower alarm status of LD power (LED) PDPWR: Value of PD power (box) and status of PD (LED) PDLWR: Value/control of lower threshold of PD power (button) and lower alarm status (LED) Center Freq: Set the FWD Center frequency value, and shows PLL alarm status ATT: Set ATT to control FWD gain, and shows it’s value.
ASD On/Off: When input upper threshold alarm is occurs, set ASD activation, and shows its status. Pilot On/Off: Set CW signal generation, and shows its status. It is used for RVS gain setting. IN PWR: RVS input power value of RRBS IN UPR: Set RVS input upper threshold, and shows the alarm status of input upper threshold RVS. OUTPWR: RVS RF output power of RRBS ATT: Set ATT to control RVS gain, and shows it’s value.
5.8.5. Firmware download Download of firmware is normally required when functional upgrade is needed or when bug or erroneous actions of firmware are fixed. Downloading improper images (executable file of repeater CPU) may cause seriously harmful damages to equipment. Download takes the following steps. ① Convert firmware source file (*.bin) to a downloadable file format. Main menu: Action → Image Compression, toolbar: ② Open a pop-up window showing the status of the target equipment for firmware download.
Download procedure Display selected file information Select file Perform operation Display progress of firmware download 5.9. Additional features 5.9.1. ASD (Auto Shutdown) Function 1. If the power level is above the shut down level for longer than 1 second, turn off HPA. 2. During shut down state, monitor RFCHS output power. If the level is below 5dB from shut down level, turn on HPA automatically. 3. Monitor HPA output power in normal operation, and monitor RFCHS output power during shut down.
1. If the power level reaches the ALC level, prevent to increase more than ALC level by using ATT control. 2. By memorizing the existing ATT value, the ATT value before ALC can be reused even when the power is reduced.