PW1900-C Manual Kisan Telecom 2010.
Content 1. Introduction....................................................................................................................................................................5 1.1. 2. Network configuration of system .......................................................................................................................5 2.1. 3. 4. General Introduction.............................................................................................................................
6.4. Status Display ................................................................................................................................................ 29 6.5. Control Policy................................................................................................................................................. 30 6.6. Menu .................................................................................................................................................................
IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
1. Introduction 1.1. General Introduction As an equipment to clear the shadows inevitably generated among the adjacent cells of CDMA, PW1900-C can supports CDMA application and effectively repeats the signals between terminals in dead area and BTS. The main objectives of PW1900-C are as follows: - The expansion of service coverage - The enhancement of service quality at the specific areas such as in tunnel or inbuilding - The enhancement of signal strength at the places where the signal is weak 2.
the service is provided remotely. System configuration MHU Capacity: 1 Optical Branch/DOU and 6 DOU/MHU (6 Optical Branch/MHU) System Connection: Optic cable between MHU and RU Optic Wavelength: 1310nm for FWD, 1550nm for RVS Max loss of optic cable (between MHU and RU): 1 ~ 10dBo 3. System Specifications 3.1. General Specifications Item PW1900-C MHU PW1900-C RU 7U-Shelf type Enclosure Type 19” standard rack mountable Cabinet In-door use Dimension WHD 19"(482.
3.2. System specifications 3.2.1. Frequency allocation 3.2.2. System Specifications Item Specification Tx Frequency Range 1930 ~ 1990MHz Frequency Stability Remarks 0.0002PPM Capable No of FA. 10FA System Delay 5usec max. Tx-Rx Isolation 100dB min. Impedance 50 Ohm Pass-Band Ripple 3dB max. FWD Input Power -20 ~ -10dBm/total FWD Output Power 43dBm /total @ RU ANT Port RVS Input Power -60dBm/total max. RVS Output Power -20dBm/total max. System Gain FWD: 63dB max.
4. Mechanical Specifications 4.1. PW1900-C MHU 4.1.1.
[MHU composition] 9 / 42
4.1.2.
4.1.3. Mechanical specification No 1 Items Exterior view Specifications 1. Shelf attachable type to both INDOOR and OPEN RACK 2. W 19"(482.4) X H 310(7U) X D 450mm 3. Weight: 15.5 Kg 2 Material Aluminum (AL5052, AL6063) is mainly used for protection from corrosion by external environments. 3 Connector Type 1. Optic I/O: FC/APC at front side 2. RF I/O: SMA Female at rear side 3. Monitor port: SMA Female at front side 4 Power Input 1.Power: 110-120Vac, 60Hz 2.
4.1.5.
8 Optic FC/APC, optic connector PWR 9 LED2 DC power supply status of the DOU Card LD LD Alarm, Green: Normal, Red: Alarm PD PD Alarm, Green: Normal, Red: Alarm 10 RJ45(Master) 11 NMS board 12 AC INPUT 13 Tx IN 14 Rx OUT Connection port to the master for the NOC Sliding type External AC power input port (rear part) MHU FWD RF connection port from BTS (rear part) MHU RVS RF connection port to BTS (rear part) 13 / 42
4.1.6. Module Composition ① [NMS UNIT] ③ ④ ② ⑤ [PSU] No [DOU] Module ① MHU NMS Controller ② MHU PSU(Power Supply Unit) ③ MRFCOM(MHU RVS FWD Combiner) ④ MHU FSK Modem ⑤ MHU Optical Transceiver Unit (DOU) Voltage Used 9Vdc 9Vdc/6.5Vdc 6.5Vdc 9Vdc 6.
4.1.7. Function of modules No Module Functions [MHU NMS Controller] 1 Monitors/controls the status and configurable items of each module in MHU [PSU] 2 Converts AC110V into DC9V and DC6.5V and provide them to each module in MHU [MRFCOM] Detect the FWD/RVS RF signal power level from 3 RU. Also provide the connection pin to FSK modem and this module has -23dB monitor port of module output.
4.1.8. PSU PSU converts external AC110V into DC and supplies +9V, +6.5V to each module in MHU. The drawing of PSU is as follows. OUTPUT SWITCH AC_L +9V GND +9V GND +6.5V GND AC_N INPUT +6.5V GND ALM GND F.G YW396-05V(연호전자) PWRON [PSU Capacity] Output Maximum Voltage current +9V 3A +6.5V 5A Watt 59.5 W [PSU Pin Map] SWITCH PIN Type: YW396-02V Pin no. 1 2 Spec. Switch_IN Switch_Out INPUT PIN Type: YW396-05V Pin no. 1 2 3 4 5 Spec. AC_L N.C AC_N N.C F.
OUTPUT PIN type: 5566-10 (MOLEX) Pin no. 1 2 3 4 5 Spec. ALARM +6.5V +6.5V +9V +9V Pin no. 6 7 8 9 10 Spec.
4.2. PW1900-C RU 4.2.1.
4.2.2.
4.2.3. Mechanical Specification No Item Description 1. 1 Dimension: W 450mm H 630mm D 284mm (plinth included) Dimension & Weight 2. Weight: 40.5Kg 2 Method of Cooling Natural convection (Heat-sink) 3 Door Locking Type Two locks on the left side of the front of cabinet 4 Optic I/O 1. Position: Cabinet inside 2. Connector type: FC/APC * Optic cable tray is provided in the inside of cabinet. 5 6 ANT PORT Power Input 7 Ground 8 Waterproof condition 9 Misc. Features 1.
to MHU through the optic module. 4.2.5.
4.2.6. Module Composition No Module Voltage Used ① RF FWD AGC (RFAGC) 6.5Vdc ② RF FWD Band Selector for 1900MHz (RFBS) 6.5Vdc ③ Slave Optical Transceiver Unit (SOU) 6.5Vdc ④ RF Modem (FSK Modem) ⑤ RU RVS COM for Signal combing (RRCOM) ⑥ RU RVS Band Selector for 1900MHz (RRBS) ⑦ RU RVS LNA for 1900MHz (RRLNA-WG) 9Vdc ⑧ HPA for 1900MHz 29Vdc ⑨ Front-End Filter Unit (FE-Duplexer) for 1900MHz ⑩ PSU ⑪ NMS Controller ⑫ Back Board Ass’y 9Vdc 6.5Vdc 110Vac 9Vdc 6.
4.2.7. Function of Modules No Module Description [RFAGC] 1 Divides RF signal to 850MHz, 1900MHz and modem signal, and amplify the lossy RF signal due to optic cable. [RFBS] 2 Controls the gain of FWD output signal, filtered FWD band and perform the ALC function. The module output is sent to HPA. [SOU] 3 Converts E/O (or O/E) of FWD and RVS signals.
[HPA] 8 30Watt(45dBm) High power amplifier that linearly amplifies the RU CDMA signal and send to RU ANT through the FE-Duplexer. [FE-Duplexer] 9 Front end duplexer that passes through desired frequency bands. [PSU] Converts AC 110V to DC 29V, DC 9V, and DC 10 6.5V, and distributes the voltages to different modules. It includes AC power on/off switch and HPA 29V power on/off switch. [NMS] 11 Monitors the status of RU each module, and controls the configurable items of the RU modules.
4.2.8. PSU PSU converts external AC110V into DC and supplies +27V, +9V and +6.5V to modules in RU. In PSU, there two (2) on/off switches: one for AC110V, and another for HPA only. The drawing of PSU is below. OFF [PSU Capacity] Output Maximum Voltage Current 27V 16 A +9V 3A +6.5V 8A Watt 511 [PSU Pin Map] AC Input PIN Type: BR-1100-3P Pin No. 1 2 3 Spec. FG AC-N AC-L HPA 1, 2 PIN Type: BR-1100-2P Pin No. 1 2 Spec.
SUB Output PIN Type: 5566-10P (Molex) Pin No. 1 2 3 4 5 Spec. +9V +9V +6.5V +6.5V +6.5V Pin No. 6 7 8 9 10 Spec.
5.
6. Administration Program (RptMan1900) Administration program (RptMan1900) is a management program for PW1900-C and provides status monitoring and control functions to users. 6.1. System Requirement System: Desktop or laptop PC OS: Windows XP or later version Resolution: 1024 768 or more Connection Cable: 9 pin serial cable (cross type) 6.2. Cable connection The cable connection between repeater and PC (GUI program) is illustrated below.
6.3. Screen Menu Bar Title Toolbar Node Tree Work Space Section Description Window Title Displays the name of management program (GUI), i.e. RptManPW1900. Displays the type of equipment which is currently connected to program (MHU or RU). Menu Bar Presents working menu for operators. It is associated with tool icons, which can activate the tool bar menus. Toolbar Presents icons (button type) for frequently used command. User friendly icons are used.
Value Units are not displayed (omitted). Value displayed in box ( ) Control The shape of mouse cursor is changed to on controllable item. The texts of controllable LED or values are displayed in BOLD font. 6.5. Control Policy System parameter is controlled one at a time. Click a control item (button) to popup a control popup dialog. Target Equipment.
View Window MHU Window Presents MHU status window in work space Remote Window Presents RU status window in work space Cascade Cascade or tile horizon arrangement of repeater status Tile Horizon windows in work space Presents debug window in work space displaying packets Packet Debug between repeater and GUI program About RptMan1900 Help Displays version of GUI program named RptMan (Repeater Manager) 6.7.
6.8. Progrm operation 6.8.1.
6.8.3.
User Connect: Connection status of COM port of repeater PSU: Status of PSU TMPCUR: Current temperature of repeater TMPUPR: Value/control of upper threshold of temperature (button) and alarm status (LED) LD Power: Transmitted optical power level to RU LD Lower: Lower limit level of the LD power PD Power: Received optical power level from RU PD Lower: Lower limit level of the PD power 1900 Tx Input: Tx level input from 1900MHz BTS 1900 Tx Upper: Upper limit of Tx input level 1900 Tx Low
6.8.4.
LDPWR: Value of LD power (box) and status of LD (LED) LDLWR: Value/control of lower threshold of LD power (button) and lower alarm status of LD power (LED) PDPWR: Value of PD power (box) and status of PD (LED) PDLWR: Value/control of lower threshold of PD power (button) and lower alarm status (LED) INPWR: FWD RF input power display of RFBS OUTPWR: FWD RF output power display of RFBS Center Freq: Set the FWD Center frequency value, and shows PLL alarm status ATT: Set ATT to control FWD gain,
On/Off: Status/control the operation state of HPA OVTMP: Alarm status of HPA Over-temperature OVPWR: Alarm status of HPA Over-Power (LED) VSWR: Alarm status of HPA VSWR (LED) OUT PWR: Output power level of HPA (box) OUT UPR: Value/control of upper threshold of HPA output power (button), alarm status (LED) OUT LWR: Value/control of lower threshold of HPA output power (button), alarm status (LED) ALC: Set ALC level for HPA output, and shows ALC status.
6.8.5. Firmware download Download of firmware is normally required when functional upgrade is needed or when bug or erroneous actions of firmware are fixed. Downloading improper images (executable file of repeater CPU) may cause seriously harmful damages to equipment. Download takes the following steps. ① Convert firmware source file (*.bin) to a downloadable file format.
Download procedure Display selected file information Select file Perform operation Display progress of firmware download 6.9. Additional features 6.9.1. ASD (Auto Shutdown) Function 1. If the power level is above the shut down level for longer than 1 second, turn off HPA. 2. During shut down state, monitor RFCHS output power. If the level is below 5dB from shut down level, turn on HPA automatically. 3. Monitor HPA output power in normal operation, and monitor RFCHS output power during shut down.
6.9.2. ALC (Auto Level Control) Function 1. If the power level reaches the ALC level, keep the current ATT in order to maintain the ALC level. 2. By memorizing the existing ATT value, the ATT value before ALC can be reused even when the power is reduced.
Appendix A Factory setting for each equipment MHU RU Item V MHU TEMP UPR 1900/850MHz Tx IN UPR 1900/850MHz Tx IN LWR 1900/850MHz Rx OUT UPR Optic LD LWR Optic PD LWR alue 80 -10 -20 -10 0 -10 Item RU TEMP UPR RFBS ATT Hidden ATT PLL RFAGC ATT HPA On/off HPA OUT UPR HPA OUT LWR ALC Level ALC On/Off ASD Level ASD On/Off RRBS ASD RRBS IN UPR RRBS ATT RRBS Hidden ATT RRBS PLL Optic LD LWR Optic PD LWR 41 / 42 Value 80 30 30 Off 44 20 43 ON 45 ON ON -10 30 0 -10
Appendix B VFD Item of the Repeater each equipment(MHU and RU) Unit MHU Item C/M Unit Item C/M PW1900-C [MHU] M PW1900-C [RU] M F/W Version M F/W Version M Current Temp. M Current Temp.