Operation Manual Celeb® 400 DMX LED Part No.
Celeb 400 DMX LED Fixtures Celeb 400 Center Mount CEL-400C-120U Celeb 400 DMX Center Mount, Univ 120U CEL-400C-230U Celeb 400 DMX Center Mount, Univ 230U Celeb 400 Yoke Mount CEL-400Y-120U Celeb 400 DMX Yoke Mount, Univ 120U CEL-400Y-230U Celeb 400 DMX Yoke Mount, Univ 230U Celeb 400 Pole-Op CEL-400P-120U Celeb 400 DMX Pole-Op, Univ 120U CEL-400P-230U Celeb 400 DMX Pole-Op, Univ 230U Included w/ all Celeb 400 Models LVR-CE490-P Celeb 400 Louver/HP, 90° (Included) GFR-CE4 Celeb 400 Gel Frame (Included) 2
Celeb 400 DMX LED Kits KIT-C4-120U Celeb 400 DMX Center Mount Kit, Univ 120U KIT-C4-230U Celeb 400 DMX Center Mount Kit, Univ 230U Celeb 400 Center Mount Kit Kit Contents: 1 Celeb 400 DMX Center Mount 1 Flight Case Weight: 52.5 lb (24kg) Dimensions: 53.5 x 11 x 16.5” (136 x 28 x 42cm) KIT-C4Y-120U Celeb 400 DMX Yoke Mount Kit, Univ 120U KIT-C4Y-230U Celeb 400 DMX Yoke Mount Kit, Univ 230U Celeb 400 Yoke Mount Kit Kit Contents: 1 Celeb 400 DMX Yoke Mount 1 Jr.
Celeb 400 DMX Control Panel A B C D E F G A) Kelvin Preset Buttons: Kelvin buttons come preset at the factory. Factory defaults left to right are: 2700K, 3200K, 4000K, 5000K, 5500K. User can also use these preset buttons to store custom Kelvin settings. B) DMX ADDRESS – Use to set DMX address. The Celeb 400 automatically assigns 2 channels. First Channel controls Dimming; Second Channel controls Kelvin.
Fixture Power AC Input The Celeb is powered AC and includes an IEC connection. A locking power cord is included with the fixture. To remove the plug, move the red tab to release. The ballast has a built-in power supply with universal input from 100-240VAC. DC Input The Celeb can also be operated on 24VDC (input range 18-28VDC) through a 3-Pin XLR. A low voltage warning will display “LPWR” when the battery is running low.
Start Up When power is first applied to the fixture, the alphanumeric display shows the current software version. Press the On/Off button to turn on the fixture. The display will default to a Kelvin setting of 5000. Kelvin Selection There are 5 Kelvin factory preset buttons. Left to right they display 2700K, 3200K, 4000K, 5000K and 5500K. A green indicator will light to the left of the active button. Rotating the adjustment knob will change the Kelvin.
Kelvin Custom Settings In KELVIN mode, the Kelvin can be fine tuned with the adjustment knob to custom settings between 2700K to 5500K. The setting can be assigned to any preset button by holding down the desired button for 5 seconds. The Kelvin display will flash once the setting is registered. Note: When the power is turned off or removed, the fixture will remember its last setting. Dimming Press the KELVIN / DIM button. The indicator light to the left of the button will turn green.
Reset Factory Settings To reset factory settings, press and hold the LOCK / RESET button for 5 seconds. The indicator light will turn green and the display will flash 5000 and light output will be at 100%. Lock Mode Press the LOCK / RESET button to lock the Kelvin and Dim settings. An amber indicator will display in LOCK mode. In LOCK mode, controls are disabled and LOCK will appear in the display. To unlock, press the LOCK / RESET button again. The indicator light will turn green.
DMX Operation The Celeb 400 DMX operates on two DMX channels using DMX512. The first channel operates dimming; the 2nd channel operates Kelvin color temperature control. Once an address is selected, the fixture automatically assigns 2 channels. Press and hold the DMX ADDRESS button to select a DMX address. The displayed number will flash while in edit mode. Turn the dimming knob to select a valid address from 1-512. (Note: 0 or 513-999 are invalid addresses.
Note: All Kelvin indicator lights will turn green if a valid DMX signal is present. If a fixture loses its DMX signal, it will hold its last DMX command. For this reason, it is important to turn a fixture off using the DMX commands. For example, if you try to turn off the lights by turning off the dimmer board, the lights will remember their last DMX command and stay on. The fixtures require a DMX “Off” or “Black-Out” command in order to turn off.
Celeb 400 DMX Kelvin Color Temperature Dimmer Level Kelvin Color Temperature Dimmer Level 5500K 100% 5000K 75% 4000K 50% 3200K 15% 2700K 0% Note: The detailed DMX mapping for the Celeb 400 DMX fixture can be downloaded from the Operation Manual posted on www.kinoflo.com. IMPORTANT! The dimmer board/light console should have its channel set to LINEAR light output response. (LINEAR response is the default setting on most dimmer boards.
Center Mount MTP-LM Mounted on a junior stand Mounted to pipe grid The Celeb 400 Center Mount fixture includes a Lollipop w/ Junior Pin (28mm) (MTP-LM) which allows the fixture to be mounted directly onto a junior stand or hung from a grid with a junior pipe clamp. Note: The handles on the back of the fixture provide attachment points for a safety chain. A 180° turn loosens the orientation of the mount. A right turn tightens the mount.
Yoke Mount MTP-I80 The yoke has a ½” hole to accept industry standard mounting hardware. The Celeb 400 Yoke Mount fixture can hang from a grid by a junior pipe hanger using a Junior Pin Assembly for Yoke (MTP-I80), sold separately. Note: The yoke also provides an attachment point for a safety chain. Warning: Use only M5 X 10mm screws (supplied) to assemble yoke. Note that threads on the fixture are self-locking and may seem tight. Replacement screws: Part No.
Operating Pole-Op The Blue cup alters the Pan (left or right). The White cup alters the Tilt (up or down). Warning! Do not pull yoke to adjust tilt. Turn the white knob counter clockwise to angle the yoke 90°. (ParaBeam shown for illustration purposes only.) Mount Option/Rope Hang Accessory holders are also designed to enable 4-point rope hangs for specialty rigging applications. Applying Gel to Frame Option 1 - The Gel Frame comes with gel clips.
Inserting Gel Frame and Louver The Celeb includes spring loaded accessory holders and two channels to hold the Gel Frame and Honeycomb Louver. Place the long edge of the Gel Frame or Honeycomb Louver into the lower channel. Press down on the left and right corners of the Gel Frame or Louver and slip the upper edge into the upper channel of the fixture. To remove, reverse the procedure. Note: Do not press down along the top center portion of the Gel Frame or Louver.
Troubleshooting Display Protection Condition Description Normal Condition Cause/Solution OCP Over Current Protection Shut down current 2.45A in excess of 20% 2.
Accessories BRD-CE4 Celeb 400 Barndoors (Set of 4) LVR-CE460-P MTP-I80 Celeb 400 Louver/HP, 60° Junior Pin Assembly for Yoke (28mm) MTP-LM Kino 81 Lollipop w/ Junior Pin (28mm) KAS-CE4 Celeb 400 Center Flight Case KAS-CE4-C Celeb 400 Center Travel Case KAS-CE4-S Celeb 400 Center Ship Case KAS-CE4-Y Celeb 400 Yoke Ship Case 7010045 Celeb 400 Yoke Assembly 7010046 Celeb 400 Pole-Op Assembly 17
Fixture Specifications CEL-400C-120U Celeb 400 DMX Center Mount, Univ 120U Celeb 400 DMX Center Mount AC Input Voltage: Amperage VAC: DC Input Voltage: Amperage VDC: Kelvin Range: Dimming Range: Weight: Dimensions: 100~240VAC 50/60Hz, 210W 1.8A at 120VAC 18~28VDC, 198W 8.25A at 24VDC 2700K~5500K 100% ~ 1% 26 lb (12kg) 45 x 14 x 5” (114.5 x 36 x 13cm) CEL-400C-230U Celeb 400 DMX Center Mount, Univ 230U AC Input Voltage: 240~100VAC 50/60Hz, 207W Amperage VAC: 1.
CEL-400P-120U Celeb 400 DMX Pole-Op, Univ 120U Celeb 400 DMX Pole-Op AC Input Voltage: Amperage VAC: DC Input Voltage: Amperage VDC: Kelvin Range: Dimming Range: Weight: Dimensions: 100~240VAC 50/60Hz, 210W 1.8A at 120VAC 18~28VDC, 198W 8.25A at 24VDC 2700K~5500K 100% ~ 1% 26 lb (12kg) 50.5 x 16.5 x 5” (128.5 x 42 x 13cm) CEL-400P-230U Celeb 400 DMX Pole-Op, Univ 230U AC Input Voltage: 240~100VAC 50/60Hz, 207W Amperage VAC: 1.0A at 230VAC DC Input Voltage: 18~28VDC, 198W Amperage VDC: 8.
For latest Warranty information and Certifications, see Kino Flo website at www.kinoflo.com. Environmental: Disposal of Old Electrical & Electronic Equipment. This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. This product is made of recyclable materials and should be disposed of in accordance with governmental regulations. Kino Flo, Inc. 2840 N. Hollywood Way, Burbank, CA 91505, USA Tel: 818 767-6528 website: www.kinoflo.