Safety Manual

READ AND SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to install or operate the product.
Make sure that all electrical connections comply with local codes, ordinances and the National Electrical Code.
If you are unfamiliar with proper electrical wiring connections, obtain the services of a qualified electrician.
Refer to your Ceiling fan instruction manual for safety and installation instructions.
WARNING: Do not exceed MAX rating power 50W for fan and 100W for ceiling fan light.
www.rplighting.com | 4931 Paseo Nel Norte NE, Albuquerque, NM 87113 | 800.937.6925
MAKING WIRE CONNECTIONS
IMPORTANT: Before installing the receiver, make sure the power on your fan is OFF.
Connect wires by using wire connectors supplied.
The remote controller is to be used for control of DC ceiling fan and fan light only.
WARNING: To avoid the risk of electrical shock, turn the power off at the main fuse box or circuit breaker before wiring.
NOTE: Fan installation must be complete including assembly of fan blades before testing remote control.
WARNING: To reduce the risk of fire or injury, do not use this product in conjunction with any variable (Rheostat) wall control.
- Connect the Black wire(marked AC IN L) from receiver to the Live (Black wire) from house.
- Connect the White wire (marked AC IN N) from receiver to the Neutral (White white) from house.
- Connect yellow/green grounded wire to grounded wire from outlet box.
- Connect the motor wire (Red, Gray, Pink wire) from the fan to the receiver (Red, Gray, Pink wire) .
- Connect the Light wire L (Blue wire) from fan to light Live (Blue wire) from receiver.
- Connect the Light wire N (White wire) from fan to Light Neutral (White wire) from receiver.
Live In (Black)
Neutral (White)
Ground
MOTOR
MOTOR
MOTOR
AC IN L
AC IN N
L FOR LIGHT
N FOR LIGHT
Receiver
(Yellow/ Green)
RED
GRAY
PINK
WHITE
BLUE
WHITE
BLACK
Power Supply
120V AC 60Hz
RC-7,RC-9
DC CEILING FAN RF REMOTE CONTROL
FOR FAN MODELS: 1070,1080
INSTALLATION AND OPERATION INSTRUCTIONS
- Connect the White wire (marked AC IN N) from receiver to the Neutral (White white) from house.
- Connect yellow/green grounded wire to grounded wire from outlet box.
- Connect the motor wire (Red, Gray, Pink wire) from the fan to the receiver (Red, Gray, Pink wire) .
- Connect the Light wire L (Blue wire) from fan to light Live (Blue wire) from receiver.
Connect the Light wire N (White wire) from fan to Light Neutral (White wire from receiver.
RF ANT
RECEIVER
Power Supply
120V AC 60Hz
RECEIVER
RP.03252022
Ground