OWNER'S MANUAL O E L I T I Z Reverse Osmosis System R _D _m D MODEL NO. 625.385560 UltraFilter 650 m i D _W _D O Caution: Read and follow all safety rules and operating instructions before first use of this product. • Warranty Questions • How It Works • Installation ? Visit www.KenmoreWater.com or call toll free 1-800-426-9345 • Care Of (M - F, 7 AM - 6 PM CST) Repair or Parts ? CalJ toll free 1o8004694663 • Specifications See back cover for other Sears service numbers.
ONE YEAR FULL WARRANTY ON REVERSE OSMOSIS SYSTEM When installed, operated and maintained according to all instructions supplied with the product, if this Reverse Osmosis System fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME to arrange for free repair (or replacement if repair proves impossible). This warranty does not include filter cartridges or the Reverse Osmosis membrane, which are expendable items.
Unpack and Check Shipment ............................................................................. What Your Reverse Osmosis System Will do ............................................................... Plan Your installation .................................................................................. 4 5 5-6 Overview and Site Preparation ........................................................................... Step lqnstall Supply Water Fitting ..............................................
INSPECT SHIPMENT Your Reverse Osmosis Drinking Water System is shipped complete in one carton. Remove all items from your shipping carton. Check all items against the packing list below. Note any items lost or damaged in shipment. Note any damage to the shipping carton. Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or damaged items. If problems exist, refer to the website or the toll free number listed throughout this manual.
Your Reverse Osmosis (RO) Drinking Water System is a water treatment unit. It uses household water pressure to reverse a natural physical process called osmosis. Water, under pressure, is forced through a semi-permeable membrane where minerals and impurities are filtered out. Clean drinking water goes to the faucet or storage, while minerals and impurities are sent to the drain with RO waste water. The minerals and impurities are measured in water as total dissolved solids (TDS).
Typical All install parts included Under Sink Installation in package. Drain Adapter for Reverse Osmosis Waste Water Reverse Osmosis Assembly Figure 2 Typical Outside Remote Installation Faucet (Hard Water) Outside TO Faucet Reverse (]Etard Water) Osmosis Air Gap Faucet Soft, Cold Water Soft, Hot Water Soft, Cold Sediment Filter \ Reverse Osmosis System Storage _l\mk Water Meter Water Softener Additional Parts required.
OVERVIEW There are seven easy steps to installing Water system. They are as follows: your Drinking STEP 1 - install Cold Water Supply fitting STEP 2 - install Drain Adapter STEP 3 - install Reverse Osmosis Assembly STEP 4 - install Storage Tank STEP 5 - install Reverse Osmosis STEP 6 - Connect Faucet Tubing STEP 7 - Sanitize, Pressure Test, Purge System These steps are explained in detail over the next few pages.
CHOOSE TYPE OF WATER FITTING TO INSTALL Locate the cold water line in the sink cabinet. It is recommended, but not required, that the cold water line be soft water. You can use the saddle valve provided with your unit to tap into the cold water line. See Fig. 5. Or you can purchase standard pipe fittings locally such as a compression fitting. The fitting must provide a leak-tight connection to the Reverse Osmosis 1/4" tube. NOTE: Local code may dictate which type of water fitting is used.
INTRODUCTION Under A suitable drain point is needed for the reject water from the Reverse Osmosis Filter. You have two options to choose from: Single trap * Install the Drain Adapter included with your unit See Figures 6, 7 & 8. This is used in under the sink installations. The drain adapter kit is installed onto your sink drain pipe above the P-trap. See Figure 6.
Outside (Hard Faucet Outside Water) (Hard Faucet BLUE Tubing to Reverse Osmosis Air Gap Faucet Water) Soft, Cold Water Soft, Hot Water Line S0ft, C01d GREEN T_lbing to Reverse Osmosis System Remote Location Installation Sediment Filter Reverse Osmosis System YELLOWTubing to-lankStorage I Storage Tank Water Meter Water Heater Main Shutoff Valve Water Softener 1!4" RED Tubing "" Tubinc to Airgap _ / %¢ Sump I-F ( Airgap 1-1/2" Figure 9 Airgap H I-1/Z' Standpipe Laundry Tub A
INSTALL REVERSE ASSEMBLY OSMOSIS FILTER The Reverse Osmosis Filter Assembly can sit upright or lay on it's side. When planning your installation, you need to allow adequate tubing lengths to be able to access the back of the Reverse Osmosis assembly in order to change the monitor battery. See Figure 11. Figure 11 INSTALL STORAGE TANK Jr 1. Apply thread sealing tape to the threads on the nipple at the top of the tank (max. 2 wraps). See Figure 12. 2. Locate the tubing connector.
SELECT LOCATION OF REVERSE FAUCET MOUNTING HOLE You will need to select the location OSMOSIS faucet of the Reverse Osmosis Faucet. You have three options to choose from: • Use the existing sink top hole for the spray hose or soap dispenser (Must be 1-1/4" in diameter) Drill a new hole in the sink Drill a new hole in the countertop next to the sink Determine where you are going to install your Reverse Osmosis Faucet. 2. Check to ensure the Reverse Osmosis faucet will .
NOTE: If you ran the red reverse osmosis drain tubing directly to a remote drain point, disregard steps 5 and 6 and refer to instructions on page 10. 6. Mount the faucet body on to the faucet base, 1/4 turn. FAUCET ELECTRONICS The RO system will monitor the total product flow of the unit and also length of time the filters have been installed. The faucet base has an indicator light that flashes to inform you of the status of the RO membrane and filters.
HOW TO CUT AND CONNECT THE TUBES Your Reverse Osmosis Water System includes push-in fittings for quick tubing connection. Review the following instructions before connecting the tubes in the next step. Cut tubes to length 1. Use a sharp cutter or knife to cut the end of tubing. Always cut the tubing square. See Figure 16. 2. inspect the end (about 1") of the tubing to be sure there are no nicks, scratches or other rough spots, if needed, cut the tubing again. See Figure 16.
3/8" black tubing _ II II II / 1/4" red tubing NOTE: Tubing lengths should allow access to the back of the assembly for servicing. NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of saddle valves. If you live in the state of Massachusetts, review plumbing code 248-CMR of the Commonwealth of Massachusetts before proceeding with the installation.
SANITIZE THE SYSTEM Sanitizing is recommended immediately after installation of the Reverse Osmosis system. It's also recommended after servicing inner parts. It is important that the person installing or servicing the system have clean hands while handling inner parts of the system. Complete the following See Figure 22. steps to sanitize the system. 1. Turn off the water supply tem. to the Reverse Osmosis sys- 2.
PRESSURE TEST THE SYSTEM NOTE: Complete the sanitizing procedures ceding page before pressure testing. Reverse" Osmosis Faucet on the prekitchen To pressure steps. test the system, complete 1. Turn the handle of the saddle Please review the following operating using your Reverse Osmosis System: features before You will not have filtered water immediately, it may take 1-3 hours to completely fill the storage tank and create maximum flow from the Reverse Osmosis faucet.
HOW YOUR WORKS REVERSE OSMOSIS SYSTEM Introduction: Your Reverse Osmosis (RO) Drinking Water System uses your household water pressure to force water through three filters. Minerals and impurities are filtered out. Delicious tasting drinking water goes to the storage tank-ready for your use. Minerals and impurities are sent down the drain. The following paragraphs will explain in detail how your Reverse Osmosis Drinking Water System works.
PRODUCT WATER FAUCET @ air PRODUCT WATER dgravity rain WASTE WATER AUTOMATIC SHUTOFF \ WATER iN drain flow control check valve O GREEN i BLUE t_ PREFILTER Jl _ t POSTFILTER IL RED D RO MEMBRANE "_ D YELLOW [!1 Reverse Osmosis Water Flow Schematic Figure 24 Water Flow Description 1. Water enters prefilter. Sand, silt and other sediments 2. Water leaves prefilter and proceeds 3. Water enters the Reverse Osmosis 4. Processed to the Reverse Osmosis membrane.
PREFILTER/POSTFILTER MAINTENANCE Cover NOTE: It is recommended to replace the battery, prefilter and postfilter cartridges at least every 6 months of product water use. Replace more often if they begin to plug with sediments. The prefilter and postfilter are replaceable sediment cartridges with activated carbon in its composition. See Figure 25. You must periodically replace the prefilter and postfilter cartridge. This will protect the RO membrane from being destroyed by chlorine.
CHANGE COLLET AND O-RING Push o-ring seal into bottom 1. Remove the collet and o-ring from the fitting with a small screwdriver. Be careful not to scratch the inter- of port then follow with collet. _/_ nal walls of the collet port. See Figures 27 & 28. 2. Clean collet port, lubricate and insert the o-ring seal into the bottom of the port. See Figures 27 & 28. 3. Push the collet inward until it locks in place. See Figures 27 & 28.
Supply water pressure limits ..................................................... Supply water temperature limits ....................................................... Maximum total dissolved solids (TDS) ........................................................ Maximum water hardness @ 6.9 pH ............................................................. Maximum iron, manganese, hydrogen sulfide .......................................................... Chlorine in water supply (max. ppm) ................
Questions? Call The Kenrnore Water Line 1=800=426=9345 or visit KenrnoreWater.
Cause: The level of chlorine in your water supply exceeds maximum limits, and has destroyed the Reverse Osmosis membrane. Correction: Cause: The prefitter is no longer reducing chlorine from the water supply. Correction: iiii!ii iii i iiiiiii!!ii i iilii ii!:: ii iii! ii iiiiiii i i ii!!iiii i i iiii!iiii iiiii i If the water supply contains more than 2.0 ppm of chlorine, additional filtering of the water supply to the Reverse Osmosis is needed.
i!!!i!!!iiiii!!!i!iii!i i!i!! i i !! !iii!i!iii!i i iiii!!!!ii!! !!!!! ii iiiii!iiiiii !!ii!iii!iiii Cause: Drain side of faucet airgap (3/8" black tub- Correction: ing) plugged, restricted or incorrectly connected to drain point. Inspect and eliminate restriction or plug. Refer to installation instructions for proper drain connection. See page 9. Cause: Battery dead. Correction: Replace with new battery. See page 2"1. Cause: Battery installed incorrectly. Correction: Install battery correctly.
Manifold Housing PUSH-IN FITTINGS o-ring seal o©. collet __2 4_---- 16__ / _6 T cZ) '%, 5 T 7 21-- 22 14J"r \ i 1/4" red tubing 24 \ 13 Questions? 26 Call The Kenmore Water Line 1-800-426-9345 / 25 or visit KenmoreWater.
Key No. Part No. Description 1 7273337 Screw (6 req'd) 2 3 7281330 7273345 Washer (4 req'd) Automatic Shut Off Cover 4 7272658 Check Valve 5 7115432 O-ring (2 req'd) 6 7272593 Cover, PWA (includes screws) order decal below [] 7272608 Decal, PWA Cover 7 7280156 Rep'l PWA (includes screws) 8 7280164 Paddlewheel Cover (includes screws) 9 7234210 Paddlewheel & O-ring kit 10 7296521 Rep'l Manifold Assembly (incl. Key Nos.