RFID-Module Introduction Kemro K2 XE 020/C RFID-Module Internal Technical Documentation V 1.
Introduction XE 020/C List of changes Version changed from / to 1.
RFID-Module Introduction Contents 1 Introduction ................................................................................................................... 5 1.1 1.2 1.3 1.4 1.5 2 Safety notes .................................................................................................................. 8 2.1 3 3.2 3.3 5.2 5.3 5.4 RFID module DIP switch .................................................................................... 17 Status display..............................
Introduction 8.1 8.2 8.3 9 XE 020/C Maintenance ...................................................................................................... 19 Repair ................................................................................................................ 19 8.2.1 Packaging and shipping ......................................................................... 19 Waste disposal ..................................................................................................
RFID-Module Introduction 1 Introduction 1.1 Purpose of the document This planning manual describes the structure, installation and connection of the XE 020/C RFID (Radio Frequency Identification) module. The XE 020/C is only intended for use in conjunction with an operating panel from KEBA. The application and functionality of the RFID module is the same for each operating panel. 1.
Introduction XE 020/C 1.4 Notes on this document 1.4.1 Contents of document RFID module description Assembly and installation notes Description of the connections and wiring including EMC measures Description of the configuration Description of the status display Maintenance notes Accessories Technical specification 1.4.2 Not contained in this document Operating panel description (see “XE 020/C – RFID module – Project engineering manual V 1.
RFID-Module Introduction 1.
Safety notes XE 020/C 2 Safety notes 2.1 Representation At various points in this manual you will see notes and precautionary warnings regarding possible hazards. The symbols used have the following meaning: ! DANGER! ! WARNING! ! CAUTION! indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury..
RFID-Module Product overview 3 Product overview 3.1 Summary The RFID card user must hold the RFID card close to the RFID antenna on the front of the operating panel for identification. If the user's RFID card was recognised, the LED on the front panel turns green. The RFID module can also supply the data captured from the RFID card, e.g. so that it can be further processed by the kemro.view.standard program on the KEBA control. Contactless user identification with an RFID card (e.g.
Product overview XE 020/C 3.1.1 Range and detection The typical range for RFID card to XE 020/C antenna module is 30 mm for the recommended RI-I02112A-03 RFID card (assuming an aluminium front panel). The card is recognised when the RFID LED on the front of the operating panel turns green (for 3 secs) (refer to chapter “RFID status LED“). There is no provision to detect multiple cards at the same time.
RFID-Module Product overview 3.
Assembly and installation notes XE 020/C 4 Assembly and installation notes 4.1 Space requirements Please see the device dimensions for the space requirement to the rear (= installation depth). The following dimensions are recommended for the opening of the RFID module: Recommended opening 4.2 Installing the RFID module Prerequisites: To mount the XE 020/C, proceed as follows: 1) Remove the front cover by pressing the clip (1) and remove the cover (2).
RFID-Module Assembly and installation notes The clip for securing the front cover must be on the lefthand side when viewed from the front. 1 ...... Mounting wall (wall thickness between 1.5mm and 6mm 2 ...... Front panel 3 ........ RFID module 4 ........ Mounting screws Mounting the RFID module 3) Stick the front cover onto the module again (1) and secure with the clip (2). Securing the front cover 4) Secure the RFID module to the wall using the mounting screws.
Connections and wiring XE 020/C 5 Connections and wiring 5.1 EMC and wiring guidelines 5.1.1 Personal safety Safety extra-low voltage All operating panels are powered by safety extra-low voltage. 5.1.2 Why EMC-aware wiring? The immunity of an electrical system depends essentially on wiring and shielding that is designed to overcome any EMC problems. Servicing experience has shown that inadequate wiring and shielding is a common cause of system interference and failure.
RFID-Module Connections and wiring 5.3 XE 020/C module interfaces 5.3.1 Internal Connector for coaxial antenna cable The antenna module and the XE 020 RFID module both have connectors for the coaxial antenna cable. 5.3.2 Internal Connector for status LED The pin assignment is defined for the status LED connector as follows: 1 1 2 2 3 3 1...LED red 2...GND 3...LED green Status LED connector on the antenna module and XE 020 RFID module: pin assignment 5.3.
Connections and wiring XE 020/C 5.4 Cables 5.4.1 Coaxial antenna cable The maximum permitted length of the coaxial antenna cable is 300 mm. 5.4.2 Connector cable for RFID status LED Three unshielded cores are sufficient for the RFID status LED connection cable. 5.4.3 Connector cable for RFID module / OP 3xx The connection cable for the RFID module / OP 3xx must be shielded and no longer than 3 m.
RFID-Module Configuration 6 Configuration 6.1 RFID module DIP switch If the overall system contains multiple RFID modules, the HW addressing must be configured using the DIP switch. The required DIP switch is located directly on the RFID module.
Status display XE 020/C 7 Status display 7.1 RFID status LED The RFID status LED is located on the front of the operating panel and indicates the status of RFID card recognition: RFID status LED Meaning red RFID card not recognised or no authorisation green for ca. 3 sec.
RFID-Module Maintenance and repair notes 8 Maintenance and repair notes 8.1 Maintenance This device does not require regular maintenance. 8.2 Repair Only KEBA technicians may repair faulty devices, otherwise the warranty becomes void. 8.2.1 Packaging and shipping The module is placed in protective packing for shipping. Please return the packaging since KEBA tries to reuse it to minimise the environmental impact.
Accessories and spares XE 020/C 9 Accessories and spares Component Order number XE 020/C RFID module Connector cable for RFID module / OP 3xx 0.4m Connector cable for RFID module / OP 3xx 1.
RFID-Module Technical specification 10 Technical specification General Reading distance: Antenna installation: Communication protocol: Evaluation unit protection class: Signalling: 30 mm from the front panel permanently installed in the front panel according to ISO 15693 or ISO 18000-3, and suitable for Euromap 65 IP 20 3-colour LED on the printed antenna Data interface: Supply voltage: Connector plug: serial 12 V DC (+/- 5%) RJ45 Frequency response: Transmission power: Sampling rate: 13.
Relevant EC directives and applicable standards XE 020/C 11 Relevant EC directives and applicable standards 11.1 EC directives 99/5/EG R&TTE directive 11.2 Standards The following non-legally binding European standards are used to validate the RFID module's conformance to the directives. 11.2.1 Validating conformance to the R&TTE directive Personal safety: Radio sector: EMC sector: Electrical safety: EN 50364 EN 300330-2, Class 3 receiver, Class 1 as per 2000/299/EG EN 301489-3 EN 60950-1 11.2.