MOD164 900MHz MODULAR TRANSCEIVER OEM INSTALLATION AND OPERATION MANUAL NOTE: THIS MODULE IS LIMITED TO OEM INSTALLATION ONLY May 27, 2014 HK
MOD164 TRANSCEIVER INDEX DESCRIPTION ........................................................................... 2 OPERATION .............................................................................. 2 INSTALLATION ......................................................................... 4 BEFORE APPLYING POWER! ...................................................... 6 TROUBLESHOOTING ................................................................. 6 TRANSCEIVER PICTORIAL ..............................
MOD164 TRANSCEIVER DESCRIPTION The MOD164 OPERATION frequency The spectrum transceiver module for the 900 transceiver module designed to MHz ISM bands. The transceiver be compatible with US (FCC Part microcontroller includes a CPU, 15.247) GPI/O, hopping is a spread and Canadian (RSS- MOD164 a is a fully radio integrated 210) regulations for license free frequency synthesizer, a power use in the 900 MHz ISM band.
MOD164 TRANSCEIVER The MOD164 hops on 50 channel frequencies that are selected in a pseudo random order. An example of the order is: {48, 25, 17, 20, 41, 37, 36, 10, 15, 44, 30, 5, 8, 28, 6, 42, 33, 1, 23, 49, 16, 3, 19, 29, 21, 43, 31, 9, 18, 27, 22, 45, 13, 2, 32, 11, 14, 46, 12, 24, 4, 7, 38, 47, 35, 40, 50, 34, 39, 26} where Channel 1 is 902.5 MHZ and Channel 50 is 927.00 MHZ. The dwell time of the hopping is 350ms. Each channel is used equally on average.
MOD164 TRANSCEIVER INSTALLATION 1) Solder wavelength the RPSMA MOD164 compatible 2) Print and attach the label as shown below: 3) Place a label on the outside of the host enclosure in a visible area. On the label, the following: “Contains Module Transmitter FCC MOD164” ID: and Transmitter P4U- “Contains Module IC: 4534A-MOD164” 4) Connect antenna. the appropriate Either a ¼ 4 a wavelength ANT-916-CW-QW-SMA connector.
MOD164 TRANSCEIVER Application Requirements: applications. See Part 2.1091 for definitions of A) Power the mobile MOD164 peak voltage, current F) Do with draw not operate MOD164 of without the an antenna. 150mA. G) Documentations: B) Do not remove the shield host’s on the MOD164. the ¼ In User the Manual include the following: C) If you use something other than fixed applications. Transceiver with 3.3VDC nominal and a.
MOD164 TRANSCEIVER transmitter must be installed to provide a separation distance of at least 20cm from all person and not be colocated with any other transmitters except in accordance with FCC and Industry Canada multi-transmitter product procedures.” BEFORE APPLYING POWER! • Check power and ground for proper polarity. • Read the rest of this manual. TROUBLESHOOTING There are no user serviceable parts in the MOD164 Transceiver.
PARTS LIST PART NUMBER DESCRIPTION 021641A MOD164 RADIO TRANSCEIVER – WIRE ANTENNA 021642A MOD164 RADIO TRANSCEIVER – RPSMA ANTENNA There are no user-serviceable parts inside the transmitter or the receiver. Return the units for service. The information, specifications, and illustrations in this manual are those in effect at the time of printing. We reserve the right to change specifications or design at any time without notice.
MOD164 TRANSCEIVER TRANSCEIVER PICTORIAL SPECIFICATIONS Equipment Class ............................. Part 15 Spread Spectrum Transmitter FCC ID ............................................................................ P4U-MOD164 ICC (Industry Canada Certification) ID ............................. 4534A-MOD164 TRANSCEIVER Power supply ........................................................................... 3.3VDC Operating temperature - Radio.......................................
MOD164 TRANSCEIVER INSTRUCTION TO THE USER This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
MOD164 TRANSCEIVER INDUSTRY CANADA STATEMENTS This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
MOD164 TRANSCEIVER OEM Responsibilities to comply with FCC and Industry Canada Regulations The MOD164 Transceiver has been certified for integration into products only by the OEM integrators under the following conditions: This device is granted for use in Mobile only configurations per Part 2.