User Guide

Page 1 of 2
©
©
M
M
A
A
R
R
K
K
I
I
V
V
I
I
N
N
D
D
U
U
S
S
T
T
R
R
I
I
E
E
S
S
C
C
o
o
r
r
p
p
.
.
E
E
X
X
C
C
E
E
P
P
T
T
A
A
S
S
M
M
A
A
Y
Y
B
B
E
E
O
O
T
T
H
H
E
E
R
R
W
W
I
I
S
S
E
E
P
P
R
R
O
O
V
V
I
I
D
D
E
E
D
D
B
B
Y
Y
C
C
O
O
N
N
T
T
R
R
A
A
C
C
T
T
,
,
T
T
H
H
E
E
S
S
E
E
D
D
R
R
A
A
W
W
I
I
N
N
G
G
S
S
A
A
N
N
D
D
S
S
P
P
E
E
C
C
I
I
F
F
I
I
C
C
A
A
T
T
I
I
O
O
N
N
S
S
C
C
O
O
N
N
T
T
A
A
I
I
N
N
P
P
R
R
O
O
P
P
R
R
I
I
E
E
T
T
A
A
R
R
Y
Y
I
I
N
N
F
F
O
O
R
R
M
M
A
A
T
T
I
I
O
O
N
N
A
A
N
N
D
D
A
A
R
R
E
E
T
T
H
H
E
E
P
P
R
R
O
O
P
P
E
E
R
R
T
T
Y
Y
O
O
F
F
M
M
A
A
R
R
K
K
I
I
V
V
I
I
N
N
D
D
U
U
S
S
T
T
R
R
I
I
E
E
S
S
L
L
T
T
D
D
.
.
A
A
N
N
D
D
A
A
R
R
E
E
I
I
S
S
S
S
U
U
E
E
D
D
I
I
N
N
S
S
T
T
R
R
I
I
C
C
T
T
C
C
O
O
N
N
F
F
I
I
D
D
E
E
N
N
C
C
E
E
A
A
N
N
D
D
S
S
H
H
A
A
L
L
L
L
N
N
O
O
T
T
B
B
E
E
T
T
R
R
A
A
N
N
S
S
M
M
I
I
T
T
T
T
E
E
D
D
O
O
R
R
R
R
E
E
P
P
R
R
O
O
D
D
U
U
C
C
E
E
D
D
O
O
R
R
C
C
O
O
P
P
I
I
E
E
D
D
O
O
R
R
U
U
S
S
E
E
D
D
A
A
S
S
T
T
H
H
E
E
B
B
A
A
S
S
I
I
S
S
F
F
O
O
R
R
M
M
A
A
N
N
U
U
F
F
A
A
C
C
T
T
U
U
R
R
E
E
O
O
R
R
S
S
A
A
L
L
E
E
O
O
F
F
A
A
P
P
P
P
A
A
R
R
A
A
T
T
U
U
S
S
W
W
I
I
T
T
H
H
O
O
U
U
T
T
P
P
R
R
I
I
O
O
R
R
W
W
R
R
I
I
T
T
T
T
E
E
N
N
P
P
E
E
R
R
M
M
I
I
S
S
S
S
I
I
O
O
N
N
.
.
Mark IV Industries Corp.
RFM-S Transmitter Field Testing Guide
With Warning Statements
Confidential
A. Set Up TTS Reader:
Serial Comms: RS-232 19200 baud No Parity etc. standard stuff. The cable (null modem)
runs out the top of the reader; connect to any DB-9 port on your host computer. Use a
Straight through cable (male-female) if you need to extend the length.
B. Set up TTS with RFM-S Transmitter:
The RFM-S Transmitter must be inserted in Slot #1 (the left most) of the RF Rack.
C. List of Commands: (power on default)
IAGTEST Help Menu - NOT FOR PRODUCTION USE
PT <2-28 hex #> - Program Tag, MASK data must match
RT - Read Tag
IP - Initialize Tag (FP ff's)
FP <2-28 hex #> - Factory Program Tag, MSb must be 1
LP <2-28 hex #> - Lock Program Tag, MSb must be 1
TP <6 hex #> - Trim Program Tag, MSB (FF), IDLE(XX), ACTIVE(XX)
(with VERIFY ON, FP is performed with TP data)
TL - Lock Trim Values in Tag
IC [<#>] - Iteration Count, # of triggers per RT/PT
PW [<#>] us - Pulse Width, either 20, 33 or 40 us
REPEAT [<#>] - Repeat Count, repeat PT/RT/FP/TP # times - ESC to stop
DELAY [<#>|OFF] - Repeat Delay, repeat cycle delay, OFF for no screen updates
DETAIL [ON |OFF] - Repeat Detail ON/OFF, show full data during repeat cycles
INC [ON |OFF] - Repeat Increment ON/OFF, increment last 4 bytes during PT
STAT [ON |OFF] - Repeat Statistics ON/OFF, displays on last cycle
VERIFY [ON |OFF] - IP/FP/LP/TP Verify ON/OFF (PT always verifies)
PD [<#>] - Program Delay. TXDATA delay between TRIGGER and
IP/FP/LP/TP data (NOT header): # us = ~ PD x 2.4 + 60
ex. 250 (default) = ~ 660 us (nominal)
CONFIG - Return Configuration Summary
The above list can be obtained by typing ?<enter>.

Summary of content (2 pages)