UIP WIFI smart peristaltic pump User Manual Version:A/0 Kamoer fluid tech(Shanghai)Co., Ltd. www.kamoer.
Catalog QUALITY GUARANTEE ...................................................................................................................... 3 NOTICE .................................................................................................................................................. 4 FCC WARNING ..................................................................................................................................... 5 PRODUCT INFORMATION .........................................
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Quality guarantee 1.Warranty conditions Free service is limited to the warranty period under normal use and maintenance of the user's manual is valid, all due to malfunction or damage not covered under warranty. Users please take care of purchase invoices, user manual, so you can receive timely and satisfactory after-sales service. 2.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Notice We have considered the safety of the user in the process of design of the instrument. Please read the manual carefully for installing and use of the instrument. Any improper operation may cause damage or danger. 1.Safety The product belongs to Active Products. The Operator should follow the regulation rules to avoid danger. If you find any visible damage, please do not switch on.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual FCC warning This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Product Information 1.1 About UIP series peristaltic pump is using stepping motor control, commonly used in low traffic and high precision setting, configure the touch screen 480 x 272, powerful, easy to operate. Product appearance as shown in Figure 1-1.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 1-2 Port look Each interface definition: 1. Fan: A machine fan used to remove heat from the machine during operation; 2. Liquid level sensor interface: used to connect the liquid level sensor expansion component, so that the instrument has the function of liquid level detection; 3.
Kamoer fluid tech(Shanghai)Co., Ltd. 4 DTR4 Foot switch (+) 5 GND5 Foot switch (-) UIP WIFI User Manual 1.2 Case-opening Open the package before packing, check if the packaging is damaged in the shipping process. After you open the package, refer to the packing list in the Appendix, and verify that all components without fail, check for visible damage. 2.Running operation After the boot, the four title bars of the main interface are introduced: Figure 2-1 Boot interface 1.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 2.1 Continuous mode After booting up, select “Continuous Mode” in the navigation bar to enter the continuous mode control interface; in continuous mode, after clicking Start, the pump will run continuously until the stop button is clicked; Figure 2-2-1 Continuous mode interface a, Continuous mode: continuous mode title; b.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual l, Wi-Fi status display: Here shows the status of Wi-Fi, the specific Wi-Fi status refers to 3.2 ration network chapter; 2.2.1 Continuous mode setting In the continuous mode, click the "Settings" button in the lower left corner to enter the continuous mode setting interface: Figure 2-2-1-1 Continuous mode setting interface a. Tube type setting: Click to enter the tube type selection interface and select the corresponding tube type.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 2-2-1-2 Continuous Work Tube Setting Interface 2.2.2 Continuous mode level detection setting If the liquid level detection is on, when the pump is working, if the liquid level alarm is detected, the pump stops working and an alarm prompt is given; in continuous mode, click Set->Level Detection to enter the continuous mode level detection setting. interface: Figure 2-2-2-1 Continuous mode liquid level detection setting a.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 2.2 Ration mode After the power is turned on, clicking the Ration mode in the title bar will enter the ration mode work interface; in the ration mode, there are two working modes, namely the fully automatic working mode and the semi-automatic working mode; 1. Semi-automatic working mode: Click h working volume display area to set the volume.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual this function to copy a volume first; h, working volume: display the working volume, when the ration mode starts working, the value decreases with the work of the pump, indicating the working process; i. Pause time: the interval between each filling in the automatic mode of the ration mode; j. Cycle mode and progress display: The ration mode has two modes: full-automatic and semi-automatic.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual tube type. Each tube type has a corresponding relationship between the speed and the flow rate. If not, the tube type can be performed in the system setting->tube type. calibration; b, Flow rate setting: click to set the flow rate of the ration mode; c.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 2-2-2-1 Assignment mode level detection setting a, Detection switch: open and close the liquid level detection; b. Alarm type: The liquid level float has two states of floating and sinking. The state of floating and sinking of different liquid level floats is different. Here, choose which state the float is used as an alarm 2.2.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 图 2-2-3-1 分配模式复制体积 Figure 2-2-3-1 Assign mode copy volume a, Tube type: the mode of the ration mode, set in the ration mode; b, Flow rate: ration mode flow rate, set in the ration mode; c, Speed: ration mode speed, according to the ration mode flow rate setting conversion; d, Run volume: the real-time volume after the start of replication; e. Prime: Before starting to copy, you need to empty the air in the pump tube.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 2.3 System settings Figure 2-3-1 System Settings a. Tube type setting: tube type setting is used to calibrate different pump tubes; b. Wi-Fi setting: Click to set the Wi-Fi connection mode, which is divided into AP mode and router mode. The AP mode is for the mobile phone to directly connect to the machine for control.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 2-4-1 System Settings a. Tube type: the current calibrated tube model; b. Flow rate: the flow rate before calibration; c. Speed: the speed corresponding to the current flow rate; d. Calibration progress: starting from 0, when the calibration is completed, it is 100; e.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual air in the pump tube. If the pump tube is drained, there is water in the cylinder, and the water in the cylinder should be drained to ensure that the cylinder is empty; 6. Start calibration: Click the start button, the pump starts running, the calibration starts, there will be a countdown and calibration progress on the screen; 7.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.2 Ration network This unit includes Wi-Fi, which can be controlled by the Kamoer Pumps App via Android or iOS phones.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Indicates the STA router mode; Indicates the STA router mode, but the machine is not connected to the router; Indicates that the machine is waiting for the ration network status in Wi-Fi. At this time, the user can configure the machine to connect to the router on the mobile terminal and enter the STA router mode. 1.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 2.
Kamoer fluid tech(Shanghai)Co., Ltd.
Kamoer fluid tech(Shanghai)Co., Ltd.
Kamoer fluid tech(Shanghai)Co., Ltd.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.3 App module introduction The app is divided into three functional modules, as follows: 1. Continuous mode:continuous mode title, where you can switch the allocation mode; 2. Assignment mode:Assign the mode title, where you can switch to continuous mode; 3. Settings:system settings entry; 3.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 1. Continuous mode: Click the title bar work mode to switch the working mode. There are two working modes, which are continuous mode and assigned mode; 2. Acceleration and deceleration granularity: set the acceleration and deceleration granularity of the flow rate, indicating the change of the flow rate when the acceleration button/deceleration button is clicked; 3. Flow rate: Click the pop-up keyboard to set the flow rate directly; 4.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.4.1 Continuous mode liquid level detection 1. Liquid level detection: liquid level detection switch, if the liquid level detection switch is turned on, when the pump is running, if there is a liquid level alarm, the pump stops running; 2. Level alarm type: The level float has two states 0 and 1, which are used to adapt different level sensors and different float sensors. If 0 is selected, the machine recognizes that the float status is 0.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 1. Ration mode: Click the title bar work mode to switch the working mode. There are two working modes, namely continuous mode and ration mode; 2. Operation mode and progress: The ration mode operation mode is divided into automatic and semi-automatic.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.5.1 Ration mode setting 1. Set the portal: Click to enter the ration mode setting interface; 2. Operation mode: Click to switch the automatic mode and semi-automatic mode; 3. Working volume: set the working volume of the ration mode; 4. Don't know the volume: Click to enter the ration mode copy function. When the ration mode working volume does not know how much input, use the copy function to get the required volume.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.5.2 Ration mode copy function The copy volume is used when the working volume that is running in the ration mode is unknown. The principle is to fill the container to be filled, how much time (volume) is needed, and then use this time to control the pump operation for filling; Note: Prime the air in the pump tubing before copying. 1. Copy function entry: Click to enter the ration mode copy function interface; 2.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.6 System settings 1. System setting entry: Click the setting in continuous mode or ration mode to enter the system setting interface; 2. Tube type setting: Click the tube type to enter the tube type calibration interface; 3. Restore factory settings: Click to restore factory settings; 3.6.1 Tubular calibration When the accuracy of the pump is found to be reduced, the pump needs to be calibrated.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 1. Tube type: Click to enter the tube type calibration interface; 2.Start priming: Click to start Priming, click again to stop priming, when calibrating, you need to empty the air inside the pump tube; 3. Flow rate and speed: the flow rate before calibration and the speed of the corresponding tube type; 4. Long dosing: The length of time the calibration needs to be run.
Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 4.2 Storage When the pump is not working for a long time, the adjustment knob should be loosened to avoid plastic deformation of the hose for a long time. The rollers of the pump head should be kept clean and dry, otherwise it will accelerate the wear of the hose and shorten the service life of the hose. 5.Technical Support If you encounter any problems after use, please contact the manufacturer.
Kamoer fluid tech(Shanghai)Co., Ltd. Temperature 0℃ to 50℃ Humility 10%–90% UIP WIFI User Manual Appendix B packing list Item Part Description Quantit 1 UIP peristaltic Machine pump 1 2 Power wire 10A AC250V 1 3 User manual English 1 Kamoer, Kamoer text and icons are registered trademarks of Kamoer Fluid Technology (Shanghai) Co., Ltd.